Probe #fb6286f788 of ASUSTek SABERTOOTH 990FX R2.... Desktop Computer

Log: smartctl

/dev/ada0 smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.2-RELEASE-p1 amd64] (local build) Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Intel 730 and DC S35x0/3610/3700 Series SSDs Device Model: INTEL SSDSC2BB080G4 Serial Number: -- LU WWN Device Id: 5 5cd2e4 ... Firmware Version: D2012370 User Capacity: 80,026,361,856 bytes [80.0 GB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: Solid State Device Form Factor: 2.5 inches Device is: In smartctl database [for details use: -P show] ATA Version is: ACS-2 T13/2015-D revision 3 SATA Version is: SATA 2.6, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Sun Dec 13 18:15:30 2020 MSK SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x02) Offline data collection activity was completed without error. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 2) seconds. Offline data collection capabilities: (0x79) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 2) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 5 Reallocated_Sector_Ct -O--CK 100 100 000 - 0 9 Power_On_Hours -O--CK 100 100 000 - 43113 12 Power_Cycle_Count -O--CK 100 100 000 - 297 170 Available_Reservd_Space PO--CK 100 100 010 - 0 171 Program_Fail_Count -O--CK 100 100 000 - 0 172 Erase_Fail_Count -O--CK 100 100 000 - 0 174 Unsafe_Shutdown_Count -O--CK 100 100 000 - 213 175 Power_Loss_Cap_Test PO--CK 100 100 010 - 682 (227 5448) 183 SATA_Downshift_Count -O--CK 100 100 000 - 0 184 End-to-End_Error PO--CK 100 100 090 - 0 187 Reported_Uncorrect -O--CK 100 100 000 - 0 190 Temperature_Case -O---K 075 069 000 - 25 (Min/Max 23/31) 192 Unsafe_Shutdown_Count -O--CK 100 100 000 - 213 194 Temperature_Internal -O---K 100 100 000 - 32 197 Current_Pending_Sector -O--CK 100 100 000 - 0 199 CRC_Error_Count -OSRCK 100 100 000 - 934 225 Host_Writes_32MiB -O--CK 100 100 000 - 180888 226 Workld_Media_Wear_Indic -O--CK 100 100 000 - 2375 227 Workld_Host_Reads_Perc -O--CK 100 100 000 - 37 228 Workload_Minutes -O--CK 100 100 000 - 2586032 232 Available_Reservd_Space PO--CK 100 100 010 - 0 233 Media_Wearout_Indicator -O--CK 098 098 000 - 0 234 Thermal_Throttle -O--CK 100 100 000 - 0/0 241 Host_Writes_32MiB -O--CK 100 100 000 - 180888 242 Host_Reads_32MiB -O--CK 100 100 000 - 108270 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 GPL,SL R/O 1 Summary SMART error log 0x02 GPL,SL R/O 8 Comprehensive SMART error log 0x03 GPL,SL R/O 20 Ext. Comprehensive SMART error log 0x04 GPL,SL R/O 8 Device Statistics log 0x06 GPL,SL R/O 1 SMART self-test log 0x07 GPL,SL R/O 2 Extended self-test log 0x09 GPL,SL R/W 1 Selective self-test log 0x10 GPL,SL R/O 1 NCQ Command Error log 0x11 GPL,SL R/O 1 SATA Phy Event Counters log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xb0 GPL,SL VS 1 Device vendor specific log 0xb1 GPL,SL VS 33 Device vendor specific log 0xdd GPL,SL VS 1 Device vendor specific log 0xde GPL VS 768 Device vendor specific log 0xdf GPL VS 1152 Device vendor specific log 0xdf SL VS 128 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (20 sectors) Device Error Count: 228 (device log contains only the most recent 80 errors) CR = Command Register FEATR = Features Register COUNT = Count (was: Sector Count) Register LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8 LH = LBA High (was: Cylinder High) Register ] LBA LM = LBA Mid (was: Cylinder Low) Register ] Register LL = LBA Low (was: Sector Number) Register ] DV = Device (was: Device/Head) Register DC = Device Control Register ER = Error register ST = Status register Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Warning! SMART Extended Comprehensive Error Log Structure error: invalid SMART checksum. Error 228 [67] occurred at disk power-on lifetime: 40384 hours (1682 days + 16 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 84 -- 41 00 48 00 00 07 c3 25 08 40 00 Error: ICRC, ABRT at LBA = 0x07c32508 = 130229512 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 61 00 00 00 48 00 00 07 c3 25 08 40 00 15:01:03.778 WRITE FPDMA QUEUED 06 00 01 00 01 00 00 00 00 00 00 40 08 15:01:03.778 DATA SET MANAGEMENT ea 00 00 00 00 00 00 00 00 00 00 40 08 15:01:03.778 FLUSH CACHE EXT ef 00 02 00 00 00 00 00 00 00 00 40 08 15:01:03.777 SET FEATURES [Enable write cache] ef 00 aa 00 00 00 00 00 00 00 00 40 08 15:01:03.777 SET FEATURES [Enable read look-ahead] Error 227 [66] occurred at disk power-on lifetime: 40384 hours (1682 days + 16 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 84 -- 41 00 90 00 00 04 d5 ed 68 40 00 Error: ICRC, ABRT at LBA = 0x04d5ed68 = 81128808 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 61 00 00 00 90 00 00 04 d5 ed 68 40 00 15:01:03.264 WRITE FPDMA QUEUED 61 00 00 00 08 00 00 09 22 16 c8 40 00 15:01:03.264 WRITE FPDMA QUEUED 61 00 00 00 08 00 00 09 22 16 c0 40 00 15:01:03.264 WRITE FPDMA QUEUED ef 00 02 00 00 00 00 00 00 00 00 40 08 15:01:03.264 SET FEATURES [Enable write cache] ef 00 aa 00 00 00 00 00 00 00 00 40 08 15:01:03.264 SET FEATURES [Enable read look-ahead] Error 226 [65] occurred at disk power-on lifetime: 40384 hours (1682 days + 16 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 84 -- 41 00 90 00 00 04 d5 ed 68 40 00 Error: ICRC, ABRT at LBA = 0x04d5ed68 = 81128808 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 61 00 00 00 90 00 00 04 d5 ed 68 40 00 15:01:03.222 WRITE FPDMA QUEUED 61 00 00 00 08 00 00 09 22 16 c8 40 00 15:01:03.222 WRITE FPDMA QUEUED 61 00 00 00 08 00 00 09 22 16 c0 40 00 15:01:03.222 WRITE FPDMA QUEUED ef 00 02 00 00 00 00 00 00 00 00 40 08 15:01:03.221 SET FEATURES [Enable write cache] ef 00 aa 00 00 00 00 00 00 00 00 40 08 15:01:03.221 SET FEATURES [Enable read look-ahead] Error 225 [64] occurred at disk power-on lifetime: 40384 hours (1682 days + 16 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 84 -- 41 00 90 00 00 04 d5 ed 68 40 00 Error: ICRC, ABRT at LBA = 0x04d5ed68 = 81128808 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 61 00 00 00 90 00 00 04 d5 ed 68 40 00 15:01:03.168 WRITE FPDMA QUEUED 61 00 00 00 08 00 00 09 22 16 c0 40 00 15:01:03.168 WRITE FPDMA QUEUED 61 00 00 00 08 00 00 09 22 16 c8 40 00 15:01:03.168 WRITE FPDMA QUEUED ef 00 02 00 00 00 00 00 00 00 00 40 08 15:01:03.167 SET FEATURES [Enable write cache] ef 00 aa 00 00 00 00 00 00 00 00 40 08 15:01:03.167 SET FEATURES [Enable read look-ahead] Warning! SMART Extended Comprehensive Error Log Structure error: invalid SMART checksum. Error 224 [63] occurred at disk power-on lifetime: 40384 hours (1682 days + 16 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 84 -- 41 00 30 00 00 08 a5 fe f0 40 00 Error: ICRC, ABRT at LBA = 0x08a5fef0 = 145096432 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 61 00 00 00 30 00 00 08 a5 fe f0 40 00 15:01:03.018 WRITE FPDMA QUEUED 61 00 00 00 08 00 00 09 22 16 a0 40 00 15:01:03.018 WRITE FPDMA QUEUED ef 00 02 00 00 00 00 00 00 00 00 40 08 15:01:03.018 SET FEATURES [Enable write cache] ef 00 aa 00 00 00 00 00 00 00 00 40 08 15:01:03.018 SET FEATURES [Enable read look-ahead] c6 00 00 00 01 00 00 00 00 00 00 40 08 15:01:03.018 SET MULTIPLE MODE Error 223 [62] occurred at disk power-on lifetime: 40384 hours (1682 days + 16 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 84 -- 41 00 30 00 00 08 a5 fe f0 40 00 Error: ICRC, ABRT at LBA = 0x08a5fef0 = 145096432 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 61 00 00 00 30 00 00 08 a5 fe f0 40 00 15:01:02.975 WRITE FPDMA QUEUED 61 00 00 00 08 00 00 09 22 16 a0 40 00 15:01:02.975 WRITE FPDMA QUEUED ef 00 02 00 00 00 00 00 00 00 00 40 08 15:01:02.974 SET FEATURES [Enable write cache] ef 00 aa 00 00 00 00 00 00 00 00 40 08 15:01:02.974 SET FEATURES [Enable read look-ahead] c6 00 00 00 01 00 00 00 00 00 00 40 08 15:01:02.974 SET MULTIPLE MODE Error 222 [61] occurred at disk power-on lifetime: 40384 hours (1682 days + 16 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 84 -- 41 00 30 00 00 08 a5 fe f0 40 00 Error: ICRC, ABRT at LBA = 0x08a5fef0 = 145096432 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 61 00 00 00 30 00 00 08 a5 fe f0 40 00 15:01:02.921 WRITE FPDMA QUEUED 61 00 00 00 08 00 00 08 e3 73 08 40 00 15:01:02.921 WRITE FPDMA QUEUED 61 00 00 00 08 00 00 08 a5 fe e8 40 00 15:01:02.921 WRITE FPDMA QUEUED 61 00 00 00 08 00 00 08 a5 fe e0 40 00 15:01:02.920 WRITE FPDMA QUEUED 61 00 00 00 08 00 00 03 a3 99 80 40 00 15:01:02.916 WRITE FPDMA QUEUED Error 221 [60] occurred at disk power-on lifetime: 40384 hours (1682 days + 16 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 84 -- 41 00 08 00 00 04 d5 ed 48 40 00 Error: ICRC, ABRT at LBA = 0x04d5ed48 = 81128776 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 61 00 00 00 08 00 00 04 d5 ed 48 40 00 15:01:02.856 WRITE FPDMA QUEUED 61 00 00 00 08 00 00 04 43 95 48 40 00 15:01:02.856 WRITE FPDMA QUEUED 61 00 00 00 08 00 00 03 a3 99 70 40 00 15:01:02.856 WRITE FPDMA QUEUED 61 00 00 00 08 00 00 02 a1 e2 70 40 00 15:01:02.855 WRITE FPDMA QUEUED 61 00 00 00 08 00 00 09 22 16 a8 40 00 15:01:02.855 WRITE FPDMA QUEUED SMART Extended Self-test Log Version: 1 (2 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 1084 - # 2 Short offline Completed without error 00% 1060 - # 3 Short offline Completed without error 00% 1036 - # 4 Short offline Completed without error 00% 1012 - # 5 Short offline Completed without error 00% 988 - # 6 Extended offline Completed without error 00% 964 - # 7 Short offline Completed without error 00% 940 - # 8 Short offline Completed without error 00% 917 - # 9 Short offline Completed without error 00% 893 - #10 Short offline Completed without error 00% 869 - #11 Short offline Completed without error 00% 845 - #12 Short offline Completed without error 00% 821 - #13 Short offline Completed without error 00% 797 - #14 Short offline Completed without error 00% 773 - #15 Short offline Completed without error 00% 750 - #16 Short offline Completed without error 00% 726 - #17 Short offline Completed without error 00% 702 - #18 Short offline Completed without error 00% 678 - #19 Short offline Completed without error 00% 654 - #20 Short offline Completed without error 00% 630 - #21 Short offline Completed without error 00% 606 - #22 Extended offline Completed without error 00% 582 - #23 Short offline Completed without error 00% 558 - #24 Short offline Completed without error 00% 535 - #25 Short offline Completed without error 00% 511 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 1 (0x0001) Device State: Active (0) Current Temperature: 25 Celsius Power Cycle Min/Max Temperature: 23/31 Celsius Lifetime Min/Max Temperature: 2/35 Celsius Specified Max Operating Temperature: 70 Celsius Under/Over Temperature Limit Count: 0/0 Vendor specific: 00 00 5e 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/70 Celsius Min/Max Temperature Limit: 0/70 Celsius Temperature History Size (Index): 478 (231) Index Estimated Time Temperature Celsius 232 2020-12-13 10:18 26 ******* ... ..( 10 skipped). .. ******* 243 2020-12-13 10:29 26 ******* 244 2020-12-13 10:30 27 ******** ... ..( 21 skipped). .. ******** 266 2020-12-13 10:52 27 ******** 267 2020-12-13 10:53 26 ******* ... ..( 96 skipped). .. ******* 364 2020-12-13 12:30 26 ******* 365 2020-12-13 12:31 25 ****** ... ..( 19 skipped). .. ****** 385 2020-12-13 12:51 25 ****** 386 2020-12-13 12:52 26 ******* ... ..(238 skipped). .. ******* 147 2020-12-13 16:51 26 ******* 148 2020-12-13 16:52 25 ****** ... ..( 46 skipped). .. ****** 195 2020-12-13 17:39 25 ****** 196 2020-12-13 17:40 26 ******* ... ..( 7 skipped). .. ******* 204 2020-12-13 17:48 26 ******* 205 2020-12-13 17:49 25 ****** ... ..( 25 skipped). .. ****** 231 2020-12-13 18:15 25 ****** SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 2) == 0x01 0x008 4 297 --- Lifetime Power-On Resets 0x01 0x018 6 11854700332 --- Logical Sectors Written 0x01 0x020 6 401867669 --- Number of Write Commands 0x01 0x028 6 7095626019 --- Logical Sectors Read 0x01 0x030 6 92009447 --- Number of Read Commands 0x04 ===== = = === == General Errors Statistics (rev 1) == 0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors 0x04 0x010 4 62 --- Resets Between Cmd Acceptance and Completion 0x05 ===== = = === == Temperature Statistics (rev 1) == 0x05 0x008 1 25 --- Current Temperature 0x05 0x010 1 26 --- Average Short Term Temperature 0x05 0x018 1 27 --- Average Long Term Temperature 0x05 0x020 1 34 --- Highest Temperature 0x05 0x028 1 3 --- Lowest Temperature 0x05 0x030 1 32 --- Highest Average Short Term Temperature 0x05 0x038 1 15 --- Lowest Average Short Term Temperature 0x05 0x040 1 29 --- Highest Average Long Term Temperature 0x05 0x048 1 17 --- Lowest Average Long Term Temperature 0x05 0x050 4 0 --- Time in Over-Temperature 0x05 0x058 1 70 --- Specified Maximum Operating Temperature 0x05 0x060 4 0 --- Time in Under-Temperature 0x05 0x068 1 0 --- Specified Minimum Operating Temperature 0x06 ===== = = === == Transport Statistics (rev 1) == 0x06 0x008 4 10863 --- Number of Hardware Resets 0x06 0x010 4 8620 --- Number of ASR Events 0x06 0x018 4 934 --- Number of Interface CRC Errors 0x07 ===== = = === == Solid State Device Statistics (rev 1) == 0x07 0x008 1 2 --- Percentage Used Endurance Indicator |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 4 0 Command failed due to ICRC error 0x0003 4 0 R_ERR response for device-to-host data FIS 0x0004 4 0 R_ERR response for host-to-device data FIS 0x0006 4 0 R_ERR response for device-to-host non-data FIS 0x000a 4 176 Device-to-host register FISes sent due to a COMRESET 0x000b 4 0 CRC errors within host-to-device FIS 0x000d 4 0 Non-CRC errors within host-to-device FIS /dev/ada1 smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.2-RELEASE-p1 amd64] (local build) Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Hitachi Deskstar 7K1000.C Device Model: Hitachi HDS721010CLA332 Serial Number: -- LU WWN Device Id: 5 000cca ... Firmware Version: JP4OA3EA User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Rotation Rate: 7200 rpm Form Factor: 3.5 inches Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 2.6, 3.0 Gb/s Local Time is: Sun Dec 13 18:15:30 2020 MSK SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Disabled Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (10164) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 169) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate PO-R-- 099 099 016 - 65537 2 Throughput_Performance P-S--- 136 136 054 - 95 3 Spin_Up_Time POS--- 140 140 024 - 242 (Average 299) 4 Start_Stop_Count -O--C- 100 100 000 - 2648 5 Reallocated_Sector_Ct PO--CK 100 100 005 - 6 7 Seek_Error_Rate PO-R-- 100 100 067 - 0 8 Seek_Time_Performance P-S--- 142 142 020 - 29 9 Power_On_Hours -O--C- 090 090 000 - 75517 10 Spin_Retry_Count PO--C- 100 100 060 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 2337 192 Power-Off_Retract_Count -O--CK 098 098 000 - 3114 193 Load_Cycle_Count -O--C- 098 098 000 - 3114 194 Temperature_Celsius -O---- 181 181 000 - 33 (Min/Max 12/42) 196 Reallocated_Event_Count -O--CK 100 100 000 - 6 197 Current_Pending_Sector -O---K 100 100 000 - 0 198 Offline_Uncorrectable ---R-- 100 100 000 - 0 199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x04 GPL R/O 7 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x20 GPL R/O 1 Streaming performance log [OBS-8] 0x21 GPL R/O 1 Write stream error log 0x22 GPL R/O 1 Read stream error log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (1 sectors) Device Error Count: 10 (device log contains only the most recent 4 errors) CR = Command Register FEATR = Features Register COUNT = Count (was: Sector Count) Register LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8 LH = LBA High (was: Cylinder High) Register ] LBA LM = LBA Mid (was: Cylinder Low) Register ] Register LL = LBA Low (was: Sector Number) Register ] DV = Device (was: Device/Head) Register DC = Device Control Register ER = Error register ST = Status register Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 10 [1] occurred at disk power-on lifetime: 57777 hours (2407 days + 9 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 01 00 00 62 15 e0 77 02 00 Error: UNC at LBA = 0x6215e077 = 1645600887 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 ab 00 48 00 00 6d c8 1f 52 40 00 29d+01:05:06.598 READ FPDMA QUEUED 60 00 55 00 40 00 00 6d c8 1e fd 40 00 29d+01:05:06.598 READ FPDMA QUEUED 60 00 02 00 38 00 00 62 15 e0 76 40 00 29d+01:05:06.597 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 00 00 29d+01:05:06.590 READ LOG EXT 60 00 ab 00 28 00 00 6d c8 1f 52 40 00 29d+01:04:48.183 READ FPDMA QUEUED Error 9 [0] occurred at disk power-on lifetime: 57777 hours (2407 days + 9 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 01 00 00 62 15 e0 77 02 00 Error: UNC at LBA = 0x6215e077 = 1645600887 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 ab 00 28 00 00 6d c8 1f 52 40 00 29d+01:04:48.183 READ FPDMA QUEUED 60 00 55 00 20 00 00 6d c8 1e fd 40 00 29d+01:04:48.182 READ FPDMA QUEUED 60 00 02 00 18 00 00 62 15 e0 76 40 00 29d+01:04:48.182 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 00 00 29d+01:04:48.177 READ LOG EXT 60 00 ab 00 08 00 00 6d c8 1f 52 40 00 29d+01:04:29.819 READ FPDMA QUEUED Error 8 [3] occurred at disk power-on lifetime: 57777 hours (2407 days + 9 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 01 00 00 62 15 e0 77 02 00 Error: UNC at LBA = 0x6215e077 = 1645600887 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 ab 00 08 00 00 6d c8 1f 52 40 00 29d+01:04:29.819 READ FPDMA QUEUED 60 00 55 00 00 00 00 6d c8 1e fd 40 00 29d+01:04:29.819 READ FPDMA QUEUED 60 00 02 00 f8 00 00 62 15 e0 76 40 00 29d+01:04:29.819 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 00 00 29d+01:04:29.816 READ LOG EXT 60 00 ab 00 e8 00 00 6d c8 1f 52 40 00 29d+01:04:11.409 READ FPDMA QUEUED Error 7 [2] occurred at disk power-on lifetime: 57777 hours (2407 days + 9 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 01 00 00 62 15 e0 77 02 00 Error: UNC at LBA = 0x6215e077 = 1645600887 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 ab 00 e8 00 00 6d c8 1f 52 40 00 29d+01:04:11.409 READ FPDMA QUEUED 60 00 55 00 e0 00 00 6d c8 1e fd 40 00 29d+01:04:11.408 READ FPDMA QUEUED 60 00 02 00 d8 00 00 62 15 e0 76 40 00 29d+01:04:11.408 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 00 00 29d+01:04:11.404 READ LOG EXT 60 00 ab 00 c8 00 00 6d c8 1f 52 40 00 29d+01:03:53.006 READ FPDMA QUEUED SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 57721 - # 2 Extended offline Completed: read failure 20% 57716 1645600887 # 3 Short offline Completed without error 00% 33234 - # 4 Short offline Completed without error 00% 33210 - # 5 Short offline Completed without error 00% 33186 - # 6 Short offline Completed without error 00% 33162 - # 7 Short offline Completed without error 00% 33138 - # 8 Extended offline Completed without error 00% 33117 - # 9 Short offline Completed without error 00% 33090 - #10 Short offline Completed without error 00% 33066 - #11 Short offline Completed without error 00% 33042 - #12 Short offline Completed without error 00% 33018 - #13 Short offline Completed without error 00% 32994 - #14 Short offline Completed without error 00% 32970 - #15 Short offline Completed without error 00% 32946 - #16 Short offline Completed without error 00% 32922 - #17 Short offline Completed without error 00% 32898 - #18 Short offline Completed without error 00% 32874 - #19 Short offline Completed without error 00% 32850 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 256 (0x0100) Device State: SMART Off-line Data Collection executing in background (4) Current Temperature: 33 Celsius Power Cycle Min/Max Temperature: 31/40 Celsius Lifetime Min/Max Temperature: 12/42 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -40/70 Celsius Temperature History Size (Index): 128 (31) Index Estimated Time Temperature Celsius 32 2020-12-13 16:08 34 *************** 33 2020-12-13 16:09 34 *************** 34 2020-12-13 16:10 34 *************** 35 2020-12-13 16:11 33 ************** 36 2020-12-13 16:12 33 ************** 37 2020-12-13 16:13 34 *************** ... ..( 2 skipped). .. *************** 40 2020-12-13 16:16 34 *************** 41 2020-12-13 16:17 33 ************** 42 2020-12-13 16:18 34 *************** 43 2020-12-13 16:19 33 ************** 44 2020-12-13 16:20 34 *************** 45 2020-12-13 16:21 33 ************** 46 2020-12-13 16:22 33 ************** 47 2020-12-13 16:23 33 ************** 48 2020-12-13 16:24 34 *************** 49 2020-12-13 16:25 33 ************** 50 2020-12-13 16:26 34 *************** ... ..( 20 skipped). .. *************** 71 2020-12-13 16:47 34 *************** 72 2020-12-13 16:48 33 ************** ... ..( 27 skipped). .. ************** 100 2020-12-13 17:16 33 ************** 101 2020-12-13 17:17 34 *************** 102 2020-12-13 17:18 33 ************** ... ..( 28 skipped). .. ************** 3 2020-12-13 17:47 33 ************** 4 2020-12-13 17:48 34 *************** 5 2020-12-13 17:49 33 ************** ... ..( 25 skipped). .. ************** 31 2020-12-13 18:15 33 ************** SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 1) == 0x01 0x008 4 2337 --- Lifetime Power-On Resets 0x01 0x010 4 75517 --- Power-on Hours 0x01 0x018 6 113160361439 --- Logical Sectors Written 0x01 0x020 6 1512049391 --- Number of Write Commands 0x01 0x028 6 1856250156478 --- Logical Sectors Read 0x01 0x030 6 1756486701 --- Number of Read Commands 0x03 ===== = = === == Rotating Media Statistics (rev 1) == 0x03 0x008 4 75080 --- Spindle Motor Power-on Hours 0x03 0x010 4 75080 --- Head Flying Hours 0x03 0x018 4 3114 --- Head Load Events 0x03 0x020 4 6 --- Number of Reallocated Logical Sectors 0x03 0x028 4 39996 --- Read Recovery Attempts 0x03 0x030 4 3 --- Number of Mechanical Start Failures 0x04 ===== = = === == General Errors Statistics (rev 1) == 0x04 0x008 4 10 --- Number of Reported Uncorrectable Errors 0x04 0x010 4 5618 --- Resets Between Cmd Acceptance and Completion 0x05 ===== = = === == Temperature Statistics (rev 1) == 0x05 0x008 1 33 --- Current Temperature 0x05 0x010 1 33 N-- Average Short Term Temperature 0x05 0x018 1 35 N-- Average Long Term Temperature 0x05 0x020 1 42 --- Highest Temperature 0x05 0x028 1 12 --- Lowest Temperature 0x05 0x030 1 38 N-- Highest Average Short Term Temperature 0x05 0x038 1 0 N-- Lowest Average Short Term Temperature 0x05 0x040 1 36 N-- Highest Average Long Term Temperature 0x05 0x048 1 0 N-- Lowest Average Long Term Temperature 0x05 0x050 4 0 --- Time in Over-Temperature 0x05 0x058 1 60 --- Specified Maximum Operating Temperature 0x05 0x060 4 0 --- Time in Under-Temperature 0x05 0x068 1 0 --- Specified Minimum Operating Temperature 0x06 ===== = = === == Transport Statistics (rev 1) == 0x06 0x008 4 70322 --- Number of Hardware Resets 0x06 0x010 4 14891 --- Number of ASR Events 0x06 0x018 4 0 --- Number of Interface CRC Errors |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0009 2 176 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 168 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS /dev/ada2 smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.2-RELEASE-p1 amd64] (local build) Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Hitachi Deskstar E7K1000 Device Model: Hitachi HDE721010SLA330 Serial Number: -- LU WWN Device Id: 5 000cca ... Firmware Version: ST6OA3AA User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Rotation Rate: 7200 rpm Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 2.6, 3.0 Gb/s Local Time is: Sun Dec 13 18:15:32 2020 MSK SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Disabled APM feature is: Disabled Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (14090) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 235) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0 2 Throughput_Performance P-S--- 131 131 054 - 116 3 Spin_Up_Time POS--- 145 145 024 - 353 (Average 435) 4 Start_Stop_Count -O--C- 100 100 000 - 708 5 Reallocated_Sector_Ct PO--CK 100 100 005 - 3 7 Seek_Error_Rate PO-R-- 100 100 067 - 0 8 Seek_Time_Performance P-S--- 125 125 020 - 33 9 Power_On_Hours -O--C- 089 089 000 - 82073 10 Spin_Retry_Count PO--C- 100 100 060 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 678 192 Power-Off_Retract_Count -O--CK 099 099 000 - 2098 193 Load_Cycle_Count -O--C- 099 099 000 - 2098 194 Temperature_Celsius -O---- 157 157 000 - 38 (Min/Max 13/49) 196 Reallocated_Event_Count -O--CK 100 100 000 - 5 197 Current_Pending_Sector -O---K 100 100 000 - 0 198 Offline_Uncorrectable ---R-- 100 100 000 - 0 199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x20 GPL R/O 1 Streaming performance log [OBS-8] 0x21 GPL R/O 1 Write stream error log 0x22 GPL R/O 1 Read stream error log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 39789 - # 2 Short offline Completed without error 00% 39765 - # 3 Short offline Completed without error 00% 39741 - # 4 Short offline Completed without error 00% 39717 - # 5 Short offline Completed without error 00% 39693 - # 6 Extended offline Completed without error 00% 39672 - # 7 Short offline Completed without error 00% 39645 - # 8 Short offline Completed without error 00% 39621 - # 9 Short offline Completed without error 00% 39597 - #10 Short offline Completed without error 00% 39573 - #11 Short offline Completed without error 00% 39549 - #12 Short offline Completed without error 00% 39525 - #13 Short offline Completed without error 00% 39501 - #14 Short offline Completed without error 00% 39501 - #15 Short offline Completed without error 00% 39477 - #16 Short offline Completed without error 00% 39453 - #17 Short offline Completed without error 00% 39429 - #18 Short offline Completed without error 00% 39405 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 256 (0x0100) Device State: SMART Off-line Data Collection executing in background (4) Current Temperature: 38 Celsius Power Cycle Min/Max Temperature: 35/44 Celsius Lifetime Min/Max Temperature: 13/49 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -40/70 Celsius Temperature History Size (Index): 128 (99) Index Estimated Time Temperature Celsius 100 2020-12-13 16:08 39 ******************** ... ..( 40 skipped). .. ******************** 13 2020-12-13 16:49 39 ******************** 14 2020-12-13 16:50 38 ******************* 15 2020-12-13 16:51 38 ******************* 16 2020-12-13 16:52 39 ******************** 17 2020-12-13 16:53 38 ******************* ... ..( 81 skipped). .. ******************* 99 2020-12-13 18:15 38 ******************* SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0009 2 172 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 172 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS /dev/ada3 smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.2-RELEASE-p1 amd64] (local build) Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Hitachi Deskstar E7K1000 Device Model: Hitachi HDE721010SLA330 Serial Number: -- LU WWN Device Id: 5 000cca ... Firmware Version: ST6OA3AA User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Rotation Rate: 7200 rpm Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 2.6, 3.0 Gb/s Local Time is: Sun Dec 13 18:15:33 2020 MSK SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Disabled APM feature is: Disabled Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (14090) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 235) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0 2 Throughput_Performance P-S--- 132 132 054 - 113 3 Spin_Up_Time POS--- 145 145 024 - 354 (Average 436) 4 Start_Stop_Count -O--C- 100 100 000 - 697 5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0 7 Seek_Error_Rate PO-R-- 100 100 067 - 0 8 Seek_Time_Performance P-S--- 123 123 020 - 34 9 Power_On_Hours -O--C- 089 089 000 - 82069 10 Spin_Retry_Count PO--C- 100 100 060 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 679 192 Power-Off_Retract_Count -O--CK 099 099 000 - 2080 193 Load_Cycle_Count -O--C- 099 099 000 - 2080 194 Temperature_Celsius -O---- 162 162 000 - 37 (Min/Max 11/50) 196 Reallocated_Event_Count -O--CK 100 100 000 - 0 197 Current_Pending_Sector -O---K 100 100 000 - 0 198 Offline_Uncorrectable ---R-- 100 100 000 - 0 199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x20 GPL R/O 1 Streaming performance log [OBS-8] 0x21 GPL R/O 1 Write stream error log 0x22 GPL R/O 1 Read stream error log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 39784 - # 2 Short offline Completed without error 00% 39761 - # 3 Short offline Completed without error 00% 39737 - # 4 Short offline Completed without error 00% 39712 - # 5 Short offline Completed without error 00% 39689 - # 6 Extended offline Completed without error 00% 39668 - # 7 Short offline Completed without error 00% 39641 - # 8 Short offline Completed without error 00% 39641 - # 9 Short offline Completed without error 00% 39641 - #10 Short offline Completed without error 00% 39617 - #11 Short offline Completed without error 00% 39593 - #12 Short offline Completed without error 00% 39569 - #13 Short offline Completed without error 00% 39544 - #14 Short offline Completed without error 00% 39521 - #15 Short offline Completed without error 00% 39497 - #16 Short offline Completed without error 00% 39473 - #17 Short offline Completed without error 00% 39449 - #18 Short offline Completed without error 00% 39425 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 256 (0x0100) Device State: SMART Off-line Data Collection executing in background (4) Current Temperature: 37 Celsius Power Cycle Min/Max Temperature: 35/43 Celsius Lifetime Min/Max Temperature: 11/50 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -40/70 Celsius Temperature History Size (Index): 128 (78) Index Estimated Time Temperature Celsius 79 2020-12-13 16:08 39 ******************** ... ..( 36 skipped). .. ******************** 116 2020-12-13 16:45 39 ******************** 117 2020-12-13 16:46 38 ******************* 118 2020-12-13 16:47 38 ******************* 119 2020-12-13 16:48 39 ******************** 120 2020-12-13 16:49 38 ******************* ... ..( 19 skipped). .. ******************* 12 2020-12-13 17:09 38 ******************* 13 2020-12-13 17:10 37 ****************** 14 2020-12-13 17:11 38 ******************* 15 2020-12-13 17:12 38 ******************* 16 2020-12-13 17:13 37 ****************** 17 2020-12-13 17:14 38 ******************* 18 2020-12-13 17:15 37 ****************** 19 2020-12-13 17:16 37 ****************** 20 2020-12-13 17:17 38 ******************* 21 2020-12-13 17:18 38 ******************* 22 2020-12-13 17:19 37 ****************** 23 2020-12-13 17:20 38 ******************* 24 2020-12-13 17:21 37 ****************** ... ..( 6 skipped). .. ****************** 31 2020-12-13 17:28 37 ****************** 32 2020-12-13 17:29 38 ******************* 33 2020-12-13 17:30 37 ****************** ... ..( 16 skipped). .. ****************** 50 2020-12-13 17:47 37 ****************** 51 2020-12-13 17:48 38 ******************* 52 2020-12-13 17:49 37 ****************** ... ..( 25 skipped). .. ****************** 78 2020-12-13 18:15 37 ****************** SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0009 2 172 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 172 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS /dev/ada4 smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.2-RELEASE-p1 amd64] (local build) Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Hitachi Deskstar E7K1000 Device Model: Hitachi HDE721010SLA330 Serial Number: -- LU WWN Device Id: 5 000cca ... Firmware Version: ST6OA3AA User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Rotation Rate: 7200 rpm Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 2.6, 3.0 Gb/s Local Time is: Sun Dec 13 18:15:34 2020 MSK SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Disabled APM feature is: Disabled Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (14090) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 235) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0 2 Throughput_Performance P-S--- 130 130 054 - 122 3 Spin_Up_Time POS--- 132 132 024 - 402 (Average 464) 4 Start_Stop_Count -O--C- 100 100 000 - 699 5 Reallocated_Sector_Ct PO--CK 100 100 005 - 2 7 Seek_Error_Rate PO-R-- 100 100 067 - 0 8 Seek_Time_Performance P-S--- 125 125 020 - 33 9 Power_On_Hours -O--C- 089 089 000 - 82071 10 Spin_Retry_Count PO--C- 100 100 060 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 680 192 Power-Off_Retract_Count -O--CK 099 099 000 - 2071 193 Load_Cycle_Count -O--C- 099 099 000 - 2071 194 Temperature_Celsius -O---- 171 171 000 - 35 (Min/Max 11/49) 196 Reallocated_Event_Count -O--CK 100 100 000 - 2 197 Current_Pending_Sector -O---K 100 100 000 - 0 198 Offline_Uncorrectable ---R-- 100 100 000 - 0 199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x20 GPL R/O 1 Streaming performance log [OBS-8] 0x21 GPL R/O 1 Write stream error log 0x22 GPL R/O 1 Read stream error log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 39787 - # 2 Short offline Completed without error 00% 39763 - # 3 Short offline Completed without error 00% 39739 - # 4 Short offline Completed without error 00% 39715 - # 5 Short offline Completed without error 00% 39691 - # 6 Extended offline Completed without error 00% 39670 - # 7 Short offline Completed without error 00% 39643 - # 8 Short offline Completed without error 00% 39619 - # 9 Short offline Completed without error 00% 39595 - #10 Short offline Completed without error 00% 39571 - #11 Short offline Completed without error 00% 39547 - #12 Short offline Completed without error 00% 39523 - #13 Short offline Completed without error 00% 39499 - #14 Short offline Completed without error 00% 39475 - #15 Short offline Completed without error 00% 39451 - #16 Short offline Completed without error 00% 39427 - #17 Short offline Completed without error 00% 39403 - #18 Short offline Completed without error 00% 39379 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 256 (0x0100) Device State: SMART Off-line Data Collection executing in background (4) Current Temperature: 35 Celsius Power Cycle Min/Max Temperature: 32/41 Celsius Lifetime Min/Max Temperature: 11/49 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -40/70 Celsius Temperature History Size (Index): 128 (82) Index Estimated Time Temperature Celsius 83 2020-12-13 16:08 37 ****************** ... ..( 12 skipped). .. ****************** 96 2020-12-13 16:21 37 ****************** 97 2020-12-13 16:22 36 ***************** 98 2020-12-13 16:23 37 ****************** 99 2020-12-13 16:24 37 ****************** 100 2020-12-13 16:25 36 ***************** 101 2020-12-13 16:26 37 ****************** ... ..( 15 skipped). .. ****************** 117 2020-12-13 16:42 37 ****************** 118 2020-12-13 16:43 36 ***************** 119 2020-12-13 16:44 36 ***************** 120 2020-12-13 16:45 37 ****************** 121 2020-12-13 16:46 36 ***************** ... ..( 6 skipped). .. ***************** 0 2020-12-13 16:53 36 ***************** 1 2020-12-13 16:54 35 **************** ... ..( 80 skipped). .. **************** 82 2020-12-13 18:15 35 **************** SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0009 2 172 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 172 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS


Hardware for Linux and BSD

GitHub