Probe #f5ad8addfd of AWOW AZ51

Log: smartctl

/dev/ada0 smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p7 amd64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Crucial/Micron Client SSDs Device Model: CT240BX500SSD1 Serial Number: -- LU WWN Device Id: 0 000000 ... Firmware Version: M6CR013 User Capacity: 240,057,409,536 bytes [240 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches TRIM Command: Available, deterministic, zeroed Device is: In smartctl database 7.3/5528 ATA Version is: ACS-2 T13/2015-D revision 3 SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Fri Jan 19 18:08:20 2024 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM level is: 254 (maximum performance) Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Unavailable === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 120) seconds. Offline data collection capabilities: (0x11) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0002) Does not save SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 10) minutes. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0 5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0 9 Power_On_Hours -O--CK 100 100 050 - 15693 12 Power_Cycle_Count -O--CK 100 100 050 - 2280 171 Program_Fail_Count -O--CK 100 100 050 - 0 172 Erase_Fail_Count -O--CK 100 100 050 - 0 173 Ave_Block-Erase_Count -O--CK 100 100 050 - 97 174 Unexpect_Power_Loss_Ct -O--CK 100 100 050 - 1786 180 Unused_Reserve_NAND_Blk -O--CK 100 100 050 - 100 183 SATA_Interfac_Downshift -O--CK 100 100 050 - 0 184 Error_Correction_Count -O--CK 100 100 050 - 0 187 Reported_Uncorrect -O--CK 100 100 050 - 0 194 Temperature_Celsius -O---K 049 012 050 NOW 51 (Min/Max 29/88) 196 Reallocated_Event_Count -O--CK 100 100 050 - 0 197 Current_Pending_ECC_Cnt -O--CK 100 100 050 - 0 198 Offline_Uncorrectable ----CK 100 100 050 - 0 199 UDMA_CRC_Error_Count -O--CK 100 100 050 - 90 202 Percent_Lifetime_Remain ----CK 094 094 001 - 94 206 Write_Error_Rate -OSR-K 100 100 050 - 0 210 Success_RAIN_Recov_Cnt -O--CK 100 100 050 - 0 246 Total_LBAs_Written -O--CK 100 100 050 - 14328240392 247 Host_Program_Page_Count -O--CK 100 100 050 - 447757512 248 FTL_Program_Page_Count -O--CK 100 100 050 - 321204160 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 1 Comprehensive SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x04 GPL,SL R/O 8 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x24 GPL R/O 88 Current Device Internal Status Data log 0x25 GPL R/O 32 Saved Device Internal Status Data log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log SMART Extended Comprehensive Error Log Version: 1 (1 sectors) Device Error Count: 91 (device log contains only the most recent 4 errors) CR = Command Register FEATR = Features Register COUNT = Count (was: Sector Count) Register LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8 LH = LBA High (was: Cylinder High) Register ] LBA LM = LBA Mid (was: Cylinder Low) Register ] Register LL = LBA Low (was: Sector Number) Register ] DV = Device (was: Device/Head) Register DC = Device Control Register ER = Error register ST = Status register Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 91 [2] log entry is empty Error 90 [1] log entry is empty Error 89 [0] log entry is empty Error 88 [3] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 00 -- 00 00 00 00 00 00 00 00 00 00 00 at LBA = 0x00000000 = 0 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 30 00 58 00 00 ad 00 11 48 00 00 00:00:00.000 READ FPDMA QUEUED 60 00 30 00 58 00 00 ad 00 11 48 00 00 00:00:00.000 READ FPDMA QUEUED 60 00 30 00 58 00 00 ad 00 11 48 00 00 00:00:00.000 READ FPDMA QUEUED 60 00 30 00 58 00 00 ad 00 11 48 00 00 00:00:00.000 READ FPDMA QUEUED 60 00 30 00 58 00 00 ad 00 11 48 00 00 00:00:00.000 READ FPDMA QUEUED SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 11669 - Selective Self-tests/Logging not supported SCT Commands not supported Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 1) == 0x01 0x008 4 2280 --- Lifetime Power-On Resets 0x01 0x010 4 15693 --- Power-on Hours 0x01 0x018 6 1443338504 --- Logical Sectors Written 0x01 0x020 6 121206326 --- Number of Write Commands 0x01 0x028 6 1167258216 --- Logical Sectors Read 0x01 0x030 6 131912704 --- Number of Read Commands 0x07 ===== = = === == Solid State Device Statistics (rev 1) == 0x07 0x008 1 6 --- Percentage Used Endurance Indicator |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 4 0 Command failed due to ICRC error 0x0002 4 0 R_ERR response for data FIS 0x0005 4 0 R_ERR response for non-data FIS 0x000a 4 18 Device-to-host register FISes sent due to a COMRESET /dev/nvd0 smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p7 amd64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Number: BIWIN NA80Y1M10-256G Serial Number: -- Firmware Version: SN11457 PCI Vendor/Subsystem ID: 0x1e4b IEEE OUI Identifier: 0x000000 Total NVM Capacity: 256,060,514,304 [256 GB] Unallocated NVM Capacity: 0 Controller ID: 0 NVMe Version: 1.4 Number of Namespaces: 1 Namespace 1 Size/Capacity: 256,060,514,304 [256 GB] Namespace 1 Formatted LBA Size: 512 Namespace 1 IEEE EUI-64: 000000 ... Local Time is: Fri Jan 19 18:08:20 2024 CET Firmware Updates (0x1a): 5 Slots, no Reset required Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Log Page Attributes (0x02): Cmd_Eff_Lg Maximum Data Transfer Size: 128 Pages Warning Comp. Temp. Threshold: 90 Celsius Critical Comp. Temp. Threshold: 95 Celsius Supported Power States St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat 0 + 6.50W - - 0 0 0 0 0 0 1 + 5.80W - - 1 1 1 1 0 0 2 + 3.60W - - 2 2 2 2 0 0 3 - 0.0500W - - 3 3 3 3 5000 10000 4 - 0.0480W - - 4 4 4 4 8000 45000 Supported LBA Sizes (NSID 0x1) Id Fmt Data Metadt Rel_Perf 0 + 512 0 0 === START OF SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED SMART/Health Information (NVMe Log 0x02) Critical Warning: 0x00 Temperature: 42 Celsius Available Spare: 100% Available Spare Threshold: 1% Percentage Used: 0% Data Units Read: 3,007,786 [1.53 TB] Data Units Written: 1,845,902 [945 GB] Host Read Commands: 36,377,249 Host Write Commands: 33,574,041 Controller Busy Time: 64 Power Cycles: 43 Power On Hours: 1,197 Unsafe Shutdowns: 15 Media and Data Integrity Errors: 0 Error Information Log Entries: 0 Warning Comp. Temperature Time: 0 Critical Comp. Temperature Time: 0 Temperature Sensor 1: 42 Celsius Temperature Sensor 2: 34 Celsius Error Information (NVMe Log 0x01, 16 of 64 entries) No Errors Logged Self-test Log (NVMe Log 0x06) Self-test status: No self-test in progress Num Test_Description Status Power_on_Hours Failing_LBA NSID Seg SCT Code 0 Short Completed without error 47 - - - - -


Hardware for Linux and BSD

GitHub