/dev/sd0c
smartctl 7.1 2019-12-30 r5022 [x86_64-unknown-openbsd6.8] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: SSD2SC240G5LC709B121-511
Serial Number: --
LU WWN Device Id: 5 f8db4c ...
Firmware Version: 560ABBF0
User Capacity: 240,057,409,536 bytes [240 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Apr 8 17:35:47 2021 EEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x02) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x7d) SMART execute Offline immediate.
No Auto Offline data collection support.
Abort Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 48) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x0025) SCT Status supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0032 120 120 050 Old_age Always - 0
5 Reallocated_Sector_Ct 0x0033 098 098 003 Pre-fail Always - 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 358 (180 242 0)
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 733
171 Unknown_Attribute 0x000a 100 100 000 Old_age Always - 0
172 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0
174 Unknown_Attribute 0x0030 000 000 000 Old_age Offline - 31
177 Wear_Leveling_Count 0x0000 000 000 000 Old_age Offline - 99
181 Program_Fail_Cnt_Total 0x000a 100 100 000 Old_age Always - 0
182 Erase_Fail_Count_Total 0x0032 100 100 000 Old_age Always - 0
187 Reported_Uncorrect 0x0012 100 100 000 Old_age Always - 0
194 Temperature_Celsius 0x0022 029 062 000 Old_age Always - 29 (Min/Max 11/62)
195 Hardware_ECC_Recovered 0x001c 120 120 000 Old_age Offline - 0
196 Reallocated_Event_Count 0x0033 098 098 003 Pre-fail Always - 0
201 Unknown_SSD_Attribute 0x001c 120 120 000 Old_age Offline - 0
204 Soft_ECC_Correction 0x001c 120 120 000 Old_age Offline - 0
230 Unknown_SSD_Attribute 0x0013 100 100 000 Pre-fail Always - 100
231 Temperature_Celsius 0x0013 100 100 010 Pre-fail Always - 12884901888
233 Media_Wearout_Indicator 0x0032 000 000 000 Old_age Always - 7136
234 Unknown_Attribute 0x0032 000 000 000 Old_age Always - 2116
241 Total_LBAs_Written 0x0032 000 000 000 Old_age Always - 2116
242 Total_LBAs_Read 0x0032 000 000 000 Old_age Always - 2019
SMART Error Log not supported
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 312 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
/dev/sd1c
smartctl 7.1 2019-12-30 r5022 [x86_64-unknown-openbsd6.8] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: TS120GMTS420S
Serial Number: --
LU WWN Device Id: 5 7c3548 ...
Firmware Version: R0522A0
User Capacity: 120,034,123,776 bytes [120 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: M.2
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Apr 8 17:35:47 2021 EEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 120) seconds.
Offline data collection
capabilities: (0x11) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0002) Does not save SMART data before
entering power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 10) minutes.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x0032 100 100 050 Old_age Always - 0
5 Reallocated_Sector_Ct 0x0032 100 100 050 Old_age Always - 0
9 Power_On_Hours 0x0032 100 100 050 Old_age Always - 55
12 Power_Cycle_Count 0x0032 100 100 050 Old_age Always - 168
160 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 0
161 Unknown_Attribute 0x0033 100 100 050 Pre-fail Always - 100
163 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 15
164 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 4358
165 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 17
166 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 3
167 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 8
168 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 1500
169 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 100
175 Program_Fail_Count_Chip 0x0032 100 100 050 Old_age Always - 0
176 Erase_Fail_Count_Chip 0x0032 100 100 050 Old_age Always - 0
177 Wear_Leveling_Count 0x0032 100 100 050 Old_age Always - 0
178 Used_Rsvd_Blk_Cnt_Chip 0x0032 100 100 050 Old_age Always - 0
181 Program_Fail_Cnt_Total 0x0032 100 100 050 Old_age Always - 0
182 Erase_Fail_Count_Total 0x0032 100 100 050 Old_age Always - 0
192 Power-Off_Retract_Count 0x0032 100 100 050 Old_age Always - 16
194 Temperature_Celsius 0x0022 100 100 050 Old_age Always - 45
195 Hardware_ECC_Recovered 0x0032 100 100 050 Old_age Always - 10
196 Reallocated_Event_Count 0x0032 100 100 050 Old_age Always - 0
197 Current_Pending_Sector 0x0032 100 100 050 Old_age Always - 0
198 Offline_Uncorrectable 0x0032 100 100 050 Old_age Always - 0
199 UDMA_CRC_Error_Count 0x0032 100 100 050 Old_age Always - 0
232 Available_Reservd_Space 0x0032 100 100 050 Old_age Always - 100
241 Total_LBAs_Written 0x0030 100 100 050 Old_age Offline - 9067
242 Total_LBAs_Read 0x0030 100 100 050 Old_age Offline - 7005
245 Unknown_Attribute 0x0032 100 100 050 Old_age Always - 8109
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
Selective Self-tests/Logging not supported