Probe #e70725dd32 of HP ProBook 4730s

Log: smartctl

/dev/ada0 smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Scorpio Blue Serial ATA (AF) Device Model: WDC WD6400BPVT-60HXZT1 Serial Number: -- LU WWN Device Id: 5 0014ee ... Firmware Version: 01.01A01 User Capacity: 640,135,028,736 bytes [640 GB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 5400 rpm Form Factor: 2.5 inches Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS (minor revision not indicated) SATA Version is: SATA 2.6, 3.0 Gb/s Local Time is: Sat Jul 23 14:15:21 2022 EDT SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM level is: 128 (minimum power consumption without standby) Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (15480) seconds. Offline data collection capabilities: (0x51) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 152) minutes. SCT capabilities: (0x703d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0 3 Spin_Up_Time POS--K 206 202 021 - 666 4 Start_Stop_Count -O--CK 098 098 000 - 2110 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate POSR-K 200 200 051 - 0 9 Power_On_Hours -O--CK 094 094 000 - 4894 10 Spin_Retry_Count PO--CK 100 100 051 - 0 11 Calibration_Retry_Count -O--CK 100 100 000 - 0 12 Power_Cycle_Count -O--CK 098 098 000 - 2107 183 Runtime_Bad_Block -O--CK 100 100 000 - 0 184 End-to-End_Error PO--CK 100 100 097 - 0 187 Reported_Uncorrect -O--CK 100 100 000 - 0 188 Command_Timeout -O--CK 100 077 000 - 195 190 Airflow_Temperature_Cel -O---K 065 057 040 - 35 (Min/Max 27/35) 191 G-Sense_Error_Rate -O--CK 001 001 000 - 12973 192 Power-Off_Retract_Count -O--CK 200 200 000 - 50 193 Load_Cycle_Count -O--CK 001 001 000 - 613378 194 Temperature_Celsius -O---K 112 104 000 - 35 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 100 253 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate P--R-- 100 253 051 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 6 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log 0xa8-0xb7 GPL,SL VS 1 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xc1 GPL VS 93 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (6 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 4390 - # 2 Short offline Completed without error 00% 3077 - # 3 Short offline Completed without error 00% 2938 - # 4 Short offline Completed without error 00% 2798 - # 5 Short offline Completed without error 00% 2671 - # 6 Short offline Completed without error 00% 2496 - # 7 Short offline Completed without error 00% 2444 - # 8 Short offline Completed without error 00% 2327 - # 9 Short offline Completed without error 00% 2221 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 258 (0x0102) Device State: Active (0) Current Temperature: 35 Celsius Power Cycle Min/Max Temperature: 27/35 Celsius Lifetime Min/Max Temperature: 21/43 Celsius Under/Over Temperature Limit Count: 0/0 Vendor specific: 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -41/85 Celsius Temperature History Size (Index): 128 (118) Index Estimated Time Temperature Celsius 119 2022-07-23 12:08 36 ***************** ... ..( 19 skipped). .. ***************** 11 2022-07-23 12:28 36 ***************** 12 2022-07-23 12:29 35 **************** 13 2022-07-23 12:30 35 **************** 14 2022-07-23 12:31 35 **************** 15 2022-07-23 12:32 36 ***************** ... ..( 14 skipped). .. ***************** 30 2022-07-23 12:47 36 ***************** 31 2022-07-23 12:48 ? - 32 2022-07-23 12:49 26 ******* 33 2022-07-23 12:50 27 ******** ... ..( 2 skipped). .. ******** 36 2022-07-23 12:53 27 ******** 37 2022-07-23 12:54 28 ********* ... ..( 2 skipped). .. ********* 40 2022-07-23 12:57 28 ********* 41 2022-07-23 12:58 30 *********** 42 2022-07-23 12:59 29 ********** 43 2022-07-23 13:00 29 ********** 44 2022-07-23 13:01 30 *********** ... ..( 2 skipped). .. *********** 47 2022-07-23 13:04 30 *********** 48 2022-07-23 13:05 31 ************ 49 2022-07-23 13:06 31 ************ 50 2022-07-23 13:07 31 ************ 51 2022-07-23 13:08 32 ************* 52 2022-07-23 13:09 31 ************ 53 2022-07-23 13:10 31 ************ 54 2022-07-23 13:11 32 ************* 55 2022-07-23 13:12 32 ************* 56 2022-07-23 13:13 33 ************** 57 2022-07-23 13:14 33 ************** 58 2022-07-23 13:15 34 *************** ... ..( 3 skipped). .. *************** 62 2022-07-23 13:19 34 *************** 63 2022-07-23 13:20 35 **************** 64 2022-07-23 13:21 34 *************** 65 2022-07-23 13:22 35 **************** ... ..( 7 skipped). .. **************** 73 2022-07-23 13:30 35 **************** 74 2022-07-23 13:31 ? - 75 2022-07-23 13:32 27 ******** 76 2022-07-23 13:33 27 ******** 77 2022-07-23 13:34 28 ********* 78 2022-07-23 13:35 29 ********** 79 2022-07-23 13:36 28 ********* 80 2022-07-23 13:37 29 ********** 81 2022-07-23 13:38 30 *********** ... ..( 2 skipped). .. *********** 84 2022-07-23 13:41 30 *********** 85 2022-07-23 13:42 31 ************ 86 2022-07-23 13:43 31 ************ 87 2022-07-23 13:44 32 ************* 88 2022-07-23 13:45 31 ************ 89 2022-07-23 13:46 31 ************ 90 2022-07-23 13:47 31 ************ 91 2022-07-23 13:48 32 ************* 92 2022-07-23 13:49 32 ************* 93 2022-07-23 13:50 33 ************** 94 2022-07-23 13:51 32 ************* 95 2022-07-23 13:52 33 ************** 96 2022-07-23 13:53 33 ************** 97 2022-07-23 13:54 33 ************** 98 2022-07-23 13:55 34 *************** 99 2022-07-23 13:56 34 *************** 100 2022-07-23 13:57 33 ************** 101 2022-07-23 13:58 34 *************** ... ..( 2 skipped). .. *************** 104 2022-07-23 14:01 34 *************** 105 2022-07-23 14:02 35 **************** ... ..( 12 skipped). .. **************** 118 2022-07-23 14:15 35 **************** SCT Error Recovery Control: Read: 85 (8.5 seconds) Write: 85 (8.5 seconds) Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x000a 2 2 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x8000 4 2605 Vendor specific


Hardware for Linux and BSD

GitHub