Probe #df8bb51672 of ASUSTek M5A97 LE R2.0 Desktop Computer

Log: smartctl

/dev/ada0 smartctl 7.0 2018-12-30 r4883 [FreeBSD 12.1-RELEASE-p3 amd64] (local build) Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Blue Device Model: WDC WD10EZEX-08WN4A0 Serial Number: -- LU WWN Device Id: 5 0014ee ... Firmware Version: 01.01A01 User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Form Factor: 3.5 inches Device is: In smartctl database [for details use: -P show] ATA Version is: ACS-3 T13/2161-D revision 3b SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Mon Sep 14 17:19:20 2020 CDT SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (12180) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 126) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x3035) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 199 051 - 0 3 Spin_Up_Time POS--K 177 171 021 - 2108 4 Start_Stop_Count -O--CK 100 100 000 - 54 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 056 056 000 - 32638 10 Spin_Retry_Count -O--CK 100 253 000 - 0 11 Calibration_Retry_Count -O--CK 100 253 000 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 54 192 Power-Off_Retract_Count -O--CK 200 200 000 - 44 193 Load_Cycle_Count -O--CK 200 200 000 - 37 194 Temperature_Celsius -O---K 103 094 000 - 40 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 200 200 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 2 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 6 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log 0xa8-0xb6 GPL,SL VS 1 Device vendor specific log 0xb7 GPL,SL VS 48 Device vendor specific log 0xbd GPL,SL VS 1 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xc1 GPL VS 93 Device vendor specific log 0xdf GPL,SL VS 1 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (6 sectors) Device Error Count: 77 (device log contains only the most recent 24 errors) CR = Command Register FEATR = Features Register COUNT = Count (was: Sector Count) Register LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8 LH = LBA High (was: Cylinder High) Register ] LBA LM = LBA Mid (was: Cylinder Low) Register ] Register LL = LBA Low (was: Sector Number) Register ] DV = Device (was: Device/Head) Register DC = Device Control Register ER = Error register ST = Status register Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 77 [4] occurred at disk power-on lifetime: 29990 hours (1249 days + 14 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 00 00 00 00 13 23 48 40 00 Error: UNC at LBA = 0x00132348 = 1254216 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 08 00 38 00 00 00 0a bf 68 40 08 19d+10:58:37.329 READ FPDMA QUEUED 60 00 08 00 30 00 00 00 13 23 48 40 08 19d+10:58:37.329 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 40 08 19d+10:58:37.329 READ LOG EXT 60 00 08 00 20 00 00 00 0a bf 68 40 08 19d+10:58:33.591 READ FPDMA QUEUED 60 00 08 00 18 00 00 00 13 23 48 40 08 19d+10:58:33.591 READ FPDMA QUEUED Error 76 [3] occurred at disk power-on lifetime: 29990 hours (1249 days + 14 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 00 00 00 00 13 23 48 40 00 Error: UNC at LBA = 0x00132348 = 1254216 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 08 00 20 00 00 00 0a bf 68 40 08 19d+10:58:33.591 READ FPDMA QUEUED 60 00 08 00 18 00 00 00 13 23 48 40 08 19d+10:58:33.591 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 40 08 19d+10:58:33.591 READ LOG EXT 61 00 10 00 08 00 00 21 d8 c4 f0 40 08 19d+10:58:29.770 WRITE FPDMA QUEUED 61 00 40 00 00 00 00 21 d8 bd b0 40 08 19d+10:58:29.770 WRITE FPDMA QUEUED Error 75 [2] occurred at disk power-on lifetime: 29990 hours (1249 days + 14 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 00 00 00 00 13 23 48 40 00 Error: WP at LBA = 0x00132348 = 1254216 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 61 00 10 00 08 00 00 21 d8 c4 f0 40 08 19d+10:58:29.770 WRITE FPDMA QUEUED 61 00 40 00 00 00 00 21 d8 bd b0 40 08 19d+10:58:29.770 WRITE FPDMA QUEUED 60 00 08 00 f8 00 00 00 0a bf 68 40 08 19d+10:58:29.770 READ FPDMA QUEUED 60 00 08 00 f0 00 00 00 13 23 48 40 08 19d+10:58:29.770 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 40 08 19d+10:58:29.770 READ LOG EXT Error 74 [1] occurred at disk power-on lifetime: 29990 hours (1249 days + 14 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 00 00 00 00 13 23 48 40 00 Error: WP at LBA = 0x00132348 = 1254216 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 61 00 10 00 e0 00 00 21 d8 c4 f0 40 08 19d+10:58:26.041 WRITE FPDMA QUEUED 61 00 40 00 d8 00 00 21 d8 bd b0 40 08 19d+10:58:26.041 WRITE FPDMA QUEUED 60 00 08 00 d0 00 00 00 0a bf 68 40 08 19d+10:58:26.040 READ FPDMA QUEUED 61 00 10 00 c8 00 00 21 d8 b8 f8 40 08 19d+10:58:26.040 WRITE FPDMA QUEUED 61 00 90 00 c0 00 00 70 5c c0 78 40 08 19d+10:58:26.040 WRITE FPDMA QUEUED Error 73 [0] occurred at disk power-on lifetime: 29990 hours (1249 days + 14 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 00 00 00 00 13 23 48 40 00 Error: UNC at LBA = 0x00132348 = 1254216 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 08 00 a8 00 00 00 0a bf 68 40 08 19d+10:58:25.007 READ FPDMA QUEUED 61 00 10 00 a0 00 00 21 d8 b8 f8 40 08 19d+10:58:24.467 WRITE FPDMA QUEUED 61 00 90 00 98 00 00 70 5c c0 78 40 08 19d+10:58:22.293 WRITE FPDMA QUEUED 60 00 08 00 90 00 00 00 13 23 48 40 08 19d+10:58:22.292 READ FPDMA QUEUED 61 00 90 00 88 00 00 70 5c be 68 40 08 19d+10:58:22.271 WRITE FPDMA QUEUED Error 72 [23] occurred at disk power-on lifetime: 29990 hours (1249 days + 14 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 00 00 00 00 13 23 48 40 00 Error: UNC at LBA = 0x00132348 = 1254216 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 18 00 c8 00 00 00 0a c6 58 40 08 19d+10:58:13.095 READ FPDMA QUEUED 60 00 08 00 c0 00 00 00 1f b5 f0 40 08 19d+10:58:13.095 READ FPDMA QUEUED 60 00 08 00 b8 00 00 00 20 95 20 40 08 19d+10:58:13.095 READ FPDMA QUEUED 60 00 08 00 b0 00 00 53 ac 4a 28 40 08 19d+10:58:13.095 READ FPDMA QUEUED 60 00 08 00 a8 00 00 00 13 23 48 40 08 19d+10:58:13.095 READ FPDMA QUEUED Error 71 [22] occurred at disk power-on lifetime: 29990 hours (1249 days + 14 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 00 00 00 00 13 23 48 40 00 Error: UNC at LBA = 0x00132348 = 1254216 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 18 00 98 00 00 00 0a c6 58 40 08 19d+10:58:09.357 READ FPDMA QUEUED 60 00 08 00 90 00 00 00 1f b5 f0 40 08 19d+10:58:09.357 READ FPDMA QUEUED 60 00 08 00 88 00 00 00 20 95 20 40 08 19d+10:58:09.357 READ FPDMA QUEUED 60 00 08 00 80 00 00 53 ac 4a 28 40 08 19d+10:58:09.357 READ FPDMA QUEUED 60 00 08 00 78 00 00 00 13 23 48 40 08 19d+10:58:09.357 READ FPDMA QUEUED Error 70 [21] occurred at disk power-on lifetime: 29990 hours (1249 days + 14 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 00 00 00 00 13 23 48 40 00 Error: UNC at LBA = 0x00132348 = 1254216 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 18 00 68 00 00 00 0a c6 58 40 08 19d+10:58:05.611 READ FPDMA QUEUED 60 00 08 00 60 00 00 00 1f b5 f0 40 08 19d+10:58:05.611 READ FPDMA QUEUED 60 00 08 00 58 00 00 00 20 95 20 40 08 19d+10:58:05.611 READ FPDMA QUEUED 60 00 08 00 50 00 00 53 ac 4a 28 40 08 19d+10:58:05.611 READ FPDMA QUEUED 60 00 38 00 48 00 00 00 00 79 10 40 08 19d+10:58:05.611 READ FPDMA QUEUED SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed: read failure 90% 2157 1267424 # 2 Short offline Completed: read failure 90% 2157 1267424 SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 258 (0x0102) Device State: Active (0) Current Temperature: 40 Celsius Power Cycle Min/Max Temperature: 32/45 Celsius Lifetime Min/Max Temperature: 20/49 Celsius Under/Over Temperature Limit Count: 0/0 Vendor specific: 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -41/85 Celsius Temperature History Size (Index): 478 (442) Index Estimated Time Temperature Celsius 443 2020-09-14 09:22 40 ********************* ... ..( 14 skipped). .. ********************* 458 2020-09-14 09:37 40 ********************* 459 2020-09-14 09:38 36 ***************** ... ..( 11 skipped). .. ***************** 471 2020-09-14 09:50 36 ***************** 472 2020-09-14 09:51 37 ****************** ... ..(125 skipped). .. ****************** 120 2020-09-14 11:57 37 ****************** 121 2020-09-14 11:58 38 ******************* ... ..(119 skipped). .. ******************* 241 2020-09-14 13:58 38 ******************* 242 2020-09-14 13:59 39 ******************** ... ..( 74 skipped). .. ******************** 317 2020-09-14 15:14 39 ******************** 318 2020-09-14 15:15 40 ********************* ... ..(123 skipped). .. ********************* 442 2020-09-14 17:19 40 ********************* SCT Error Recovery Control command not supported Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 4 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x8000 4 11213991 Vendor specific /dev/ada1 smartctl 7.0 2018-12-30 r4883 [FreeBSD 12.1-RELEASE-p3 amd64] (local build) Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Blue Device Model: WDC WD10EZEX-08WN4A0 Serial Number: -- LU WWN Device Id: 5 0014ee ... Firmware Version: 01.01A01 User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Form Factor: 3.5 inches Device is: In smartctl database [for details use: -P show] ATA Version is: ACS-3 T13/2161-D revision 3b SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Mon Sep 14 17:19:20 2020 CDT SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (12540) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 130) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x3035) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0 3 Spin_Up_Time POS--K 173 171 021 - 2333 4 Start_Stop_Count -O--CK 100 100 000 - 54 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 056 056 000 - 32638 10 Spin_Retry_Count -O--CK 100 253 000 - 0 11 Calibration_Retry_Count -O--CK 100 253 000 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 54 192 Power-Off_Retract_Count -O--CK 200 200 000 - 44 193 Load_Cycle_Count -O--CK 200 200 000 - 32 194 Temperature_Celsius -O---K 105 097 000 - 38 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 200 200 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 6 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log 0xa8-0xb6 GPL,SL VS 1 Device vendor specific log 0xb7 GPL,SL VS 48 Device vendor specific log 0xbd GPL,SL VS 1 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xc1 GPL VS 93 Device vendor specific log 0xdf GPL,SL VS 1 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (6 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 258 (0x0102) Device State: Active (0) Current Temperature: 38 Celsius Power Cycle Min/Max Temperature: 30/43 Celsius Lifetime Min/Max Temperature: 19/46 Celsius Under/Over Temperature Limit Count: 0/0 Vendor specific: 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -41/85 Celsius Temperature History Size (Index): 478 (451) Index Estimated Time Temperature Celsius 452 2020-09-14 09:22 38 ******************* ... ..( 14 skipped). .. ******************* 467 2020-09-14 09:37 38 ******************* 468 2020-09-14 09:38 34 *************** ... ..( 34 skipped). .. *************** 25 2020-09-14 10:13 34 *************** 26 2020-09-14 10:14 35 **************** ... ..( 94 skipped). .. **************** 121 2020-09-14 11:49 35 **************** 122 2020-09-14 11:50 36 ***************** ... ..(122 skipped). .. ***************** 245 2020-09-14 13:53 36 ***************** 246 2020-09-14 13:54 37 ****************** ... ..( 75 skipped). .. ****************** 322 2020-09-14 15:10 37 ****************** 323 2020-09-14 15:11 38 ******************* ... ..(127 skipped). .. ******************* 451 2020-09-14 17:19 38 ******************* SCT Error Recovery Control command not supported Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 4 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x8000 4 11213993 Vendor specific /dev/ada2 smartctl 7.0 2018-12-30 r4883 [FreeBSD 12.1-RELEASE-p3 amd64] (local build) Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Caviar Blue Serial ATA Device Model: WDC WD1600AAJS-00PSA0 Serial Number: -- LU WWN Device Id: 5 0014ee ... Firmware Version: 05.06H05 User Capacity: 160,041,885,696 bytes [160 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: ATA/ATAPI-7 (minor revision not indicated) Local Time is: Mon Sep 14 17:19:20 2020 CDT SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Disabled APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 4200) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 56) minutes. Conveyance self-test routine recommended polling time: ( 6) minutes. SCT capabilities: (0x103f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-- 200 200 051 - 0 3 Spin_Up_Time PO---- 180 161 021 - 1966 4 Start_Stop_Count -O--CK 100 100 000 - 269 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-- 200 200 051 - 0 9 Power_On_Hours -O--CK 001 001 000 - 101015 10 Spin_Retry_Count -O--C- 100 100 051 - 0 11 Calibration_Retry_Count -O--C- 100 100 051 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 265 192 Power-Off_Retract_Count -O--CK 200 200 000 - 212 193 Load_Cycle_Count -O--CK 200 200 000 - 276 194 Temperature_Celsius -O---K 103 090 000 - 40 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--C- 200 200 000 - 0 198 Offline_Uncorrectable ----C- 200 200 000 - 0 199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 200 200 051 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 6 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log 0xa8-0xb7 GPL,SL VS 1 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xc1 GPL VS 12 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (6 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 2 SCT Version (vendor specific): 258 (0x0102) Device State: SMART Off-line Data Collection executing in background (4) Current Temperature: 40 Celsius Power Cycle Min/Max Temperature: 31/45 Celsius Lifetime Min/Max Temperature: 35/54 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 5/60 Celsius Min/Max Temperature Limit: 1/85 Celsius Temperature History Size (Index): 128 (4) Index Estimated Time Temperature Celsius 5 2020-09-14 15:12 38 ******************* ... ..(103 skipped). .. ******************* 109 2020-09-14 16:56 38 ******************* 110 2020-09-14 16:57 39 ******************** ... ..( 3 skipped). .. ******************** 114 2020-09-14 17:01 39 ******************** 115 2020-09-14 17:02 40 ********************* ... ..( 15 skipped). .. ********************* 3 2020-09-14 17:18 40 ********************* 4 2020-09-14 17:19 38 ******************* SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x000a 2 2 Device-to-host register FISes sent due to a COMRESET 0x8000 4 11213830 Vendor specific /dev/ada3 smartctl 7.0 2018-12-30 r4883 [FreeBSD 12.1-RELEASE-p3 amd64] (local build) Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Blue Device Model: WDC WD10EZEX-08WN4A0 Serial Number: -- LU WWN Device Id: 5 0014ee ... Firmware Version: 01.01A01 User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Form Factor: 3.5 inches Device is: In smartctl database [for details use: -P show] ATA Version is: ACS-3 T13/2161-D revision 3b SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Mon Sep 14 17:19:20 2020 CDT SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (11700) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 121) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x3035) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0 3 Spin_Up_Time POS--K 184 173 021 - 1758 4 Start_Stop_Count -O--CK 100 100 000 - 48 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 059 059 000 - 30167 10 Spin_Retry_Count -O--CK 100 253 000 - 0 11 Calibration_Retry_Count -O--CK 100 253 000 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 48 192 Power-Off_Retract_Count -O--CK 200 200 000 - 40 193 Load_Cycle_Count -O--CK 200 200 000 - 20 194 Temperature_Celsius -O---K 106 098 000 - 37 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 200 200 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 6 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log 0xa8-0xb6 GPL,SL VS 1 Device vendor specific log 0xb7 GPL,SL VS 48 Device vendor specific log 0xbd GPL,SL VS 1 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xc1 GPL VS 93 Device vendor specific log 0xdf GPL,SL VS 1 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (6 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 258 (0x0102) Device State: Active (0) Current Temperature: 37 Celsius Power Cycle Min/Max Temperature: 29/43 Celsius Lifetime Min/Max Temperature: 18/45 Celsius Under/Over Temperature Limit Count: 0/0 Vendor specific: 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -41/85 Celsius Temperature History Size (Index): 478 (466) Index Estimated Time Temperature Celsius 467 2020-09-14 09:22 34 *************** ... ..( 49 skipped). .. *************** 39 2020-09-14 10:12 34 *************** 40 2020-09-14 10:13 35 **************** ... ..(122 skipped). .. **************** 163 2020-09-14 12:16 35 **************** 164 2020-09-14 12:17 36 ***************** ... ..( 71 skipped). .. ***************** 236 2020-09-14 13:29 36 ***************** 237 2020-09-14 13:30 37 ****************** ... ..(144 skipped). .. ****************** 382 2020-09-14 15:55 37 ****************** 383 2020-09-14 15:56 33 ************** ... ..( 53 skipped). .. ************** 437 2020-09-14 16:50 33 ************** 438 2020-09-14 16:51 34 *************** ... ..( 27 skipped). .. *************** 466 2020-09-14 17:19 34 *************** SCT Error Recovery Control command not supported Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 4 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x8000 4 11213286 Vendor specific


Hardware for Linux and BSD

GitHub