Probe #d84548dd9b of Dell XPS M1330

Log: smartctl

/dev/ada0 smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-STABLE amd64] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: Patriot Inferno 60GB SSD Serial Number: -- LU WWN Device Id: 5 00232d ... Firmware Version: 320A13F0 User Capacity: 60,022,480,896 bytes [60.0 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device TRIM Command: Available, deterministic Device is: Not in smartctl database 7.3/5319 ATA Version is: ATA8-ACS T13/1699-D revision 6 SATA Version is: SATA 2.6, 3.0 Gb/s Local Time is: Sat Sep 10 17:18:35 2022 HDT SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Unknown (0x100) === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x7f) SMART execute Offline immediate. Auto Offline data collection on/off support. Abort Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 48) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-- 120 120 050 - 0 5 Reallocated_Sector_Ct PO--CK 099 099 003 - 96 9 Power_On_Hours -O--CK 100 100 000 - 22470 (92 54 0) 12 Power_Cycle_Count -O--CK 100 100 000 - 731 171 Unknown_Attribute ------ 000 000 000 - 0 172 Unknown_Attribute ------ 000 000 000 - 0 174 Unknown_Attribute ----CK 000 000 000 - 164 177 Wear_Leveling_Count ------ 000 000 --- - 1 181 Program_Fail_Cnt_Total ------ 000 000 000 - 0 182 Erase_Fail_Count_Total ------ 000 000 000 - 0 187 Reported_Uncorrect -O--CK 100 100 000 - 0 194 Temperature_Celsius -O---K 000 000 000 - 0 195 Hardware_ECC_Recovered --SRC- 120 120 000 - 0 196 Reallocated_Event_Count PO--CK 100 100 003 - 0 231 Unknown_SSD_Attribute PO--C- 098 098 010 - 0 233 Media_Wearout_Indicator ------ 000 000 000 - 7104 234 Unknown_Attribute ------ 000 000 000 - 6336 241 Total_LBAs_Written -O--CK 000 000 000 - 6336 242 Total_LBAs_Read -O--CK 000 000 000 - 20480 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL,SL R/O 1 SATA Phy Event Counters log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xb7 GPL,SL VS 16 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log (GP Log 0x03) not supported SMART Error Log not supported SMART Extended Self-test Log Version: 1 (1 sectors) No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 0 (0x0000) Device State: Active (0) Current Temperature: ? Celsius Power Cycle Min/Max Temperature: 127/-127 Celsius Lifetime Min/Max Temperature: 0/ 0 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: ?/ ? Celsius Min/Max Temperature Limit: ?/ ? Celsius Temperature History Size (Index): 478 (479) Invalid Temperature History Size or Index SCT Error Recovery Control: Read: 256 (25.6 seconds) Write: 256 (25.6 seconds) Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x000a 2 2 Device-to-host register FISes sent due to a COMRESET


Hardware for Linux and BSD

GitHub