/dev/ada0
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Momentus 5400.4
Device Model: ST9250827AS
Serial Number: --
LU WWN Device Id: 5 000c50 ...
Firmware Version: 3.AAA
User Capacity: 250,059,350,016 bytes [250 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 5400 rpm
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 2.6, 1.5 Gb/s
Local Time is: Mon Mar 20 03:03:52 2023 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 426) seconds.
Offline data collection
capabilities: (0x53) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 92) minutes.
SCT capabilities: (0x0001) SCT Status supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 100 253 006 - 0
3 Spin_Up_Time PO---- 099 099 000 - 0
4 Start_Stop_Count -O--CK 098 098 020 - 2912
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
7 Seek_Error_Rate POSR-- 079 060 030 - 13186920232
9 Power_On_Hours -O--CK 076 076 000 - 21735
10 Spin_Retry_Count PO--C- 100 100 034 - 0
12 Power_Cycle_Count -O--CK 098 098 020 - 2921
187 Reported_Uncorrect -O--CK 100 100 000 - 0
189 High_Fly_Writes -O-RCK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 066 037 045 Past 34 (Min/Max 8/63 #42)
191 G-Sense_Error_Rate -O--CK 100 100 000 - 15
192 Power-Off_Retract_Count -O--CK 100 100 000 - 1865
193 Load_Cycle_Count -O---K 001 001 000 - 507399
194 Temperature_Celsius -O-RC- 034 063 000 - 34 (0 8 0 0 0)
195 Hardware_ECC_Recovered -O--C- 074 057 000 - 48952043
197 Current_Pending_Sector ----C- 100 100 000 - 0
198 Offline_Uncorrectable -OSRCK 100 100 000 - 0
199 UDMA_CRC_Error_Count ------ 200 090 000 - 1724
200 Multi_Zone_Error_Rate -O--CK 100 253 000 - 0
202 Data_Address_Mark_Errs ------ 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory not supported
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 SL R/O 5 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 SL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 SL R/O 1 NCQ Command Error log
0x11 SL R/O 1 SATA Phy Event Counters log
0x20 SL R/O 1 Streaming performance log [OBS-8]
0x21 SL R/O 1 Write stream error log
0x22 SL R/O 1 Read stream error log
0x23 SL R/O 1 Delayed sector log [OBS-8]
0x80-0x9f SL R/W 16 Host vendor specific log
0xa0 SL VS 1 Device vendor specific log
0xa1 SL VS 20 Device vendor specific log
0xa2 SL VS 101 Device vendor specific log
0xa8 SL VS 20 Device vendor specific log
0xa9 SL VS 1 Device vendor specific log
0xe0 SL R/W 1 SCT Command/Status
0xe1 SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
ATA Error Count: 1746 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 1746 occurred at disk power-on lifetime: 5259 hours (219 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 2f 34 51 f4 e0
Error: ICRC, ABRT 47 sectors at LBA = 0x00f45134 = 16011572
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 03 f0 73 50 f4 e0 00 00:12:06.575 READ DMA EXT
25 03 10 63 50 f4 e0 00 00:12:06.572 READ DMA EXT
25 03 f0 73 4f f4 e0 00 00:12:06.571 READ DMA EXT
25 03 10 63 4f f4 e0 00 00:12:06.568 READ DMA EXT
25 03 f0 73 4e f4 e0 00 00:12:06.568 READ DMA EXT
Error 1745 occurred at disk power-on lifetime: 5259 hours (219 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 2f 34 3d f4 e0
Error: ICRC, ABRT 47 sectors at LBA = 0x00f43d34 = 16006452
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 03 f0 73 3c f4 e0 00 00:12:05.890 READ DMA EXT
25 03 10 63 3c f4 e0 00 00:12:05.886 READ DMA EXT
25 03 f0 73 3b f4 e0 00 00:12:05.913 READ DMA EXT
25 03 10 63 3b f4 e0 00 00:12:05.913 READ DMA EXT
25 03 f0 73 3a f4 e0 00 00:12:05.909 READ DMA EXT
Error 1744 occurred at disk power-on lifetime: 5259 hours (219 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 5f dc 3f db e0
Error: ICRC, ABRT 95 sectors at LBA = 0x00db3fdc = 14368732
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 03 f0 4b 3f db e0 00 00:12:04.713 READ DMA EXT
25 03 10 3b 3f db e0 00 00:12:04.712 READ DMA EXT
25 03 f0 4b 3e db e0 00 00:12:04.709 READ DMA EXT
25 03 10 3b 3e db e0 00 00:12:04.708 READ DMA EXT
25 03 f0 4b 3d db e0 00 00:12:04.705 READ DMA EXT
Error 1743 occurred at disk power-on lifetime: 5259 hours (219 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 2f bc b9 c4 e0
Error: ICRC, ABRT 47 sectors at LBA = 0x00c4b9bc = 12892604
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 03 40 ab b9 c4 e0 00 00:12:01.759 READ DMA EXT
25 03 20 8b b9 c4 e0 00 00:12:01.756 READ DMA EXT
25 03 02 53 de 19 e0 00 00:12:01.755 READ DMA EXT
25 03 10 5b b2 43 e0 00 00:12:01.752 READ DMA EXT
25 03 20 3b b2 43 e0 00 00:12:01.972 READ DMA EXT
Error 1742 occurred at disk power-on lifetime: 5259 hours (219 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 6f c4 a6 7a e0
Error: ICRC, ABRT 111 sectors at LBA = 0x007aa6c4 = 8038084
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 03 f0 43 a6 7a e0 00 00:11:55.537 READ DMA EXT
25 03 f0 53 a5 7a e0 00 00:11:55.534 READ DMA EXT
25 03 10 b2 86 50 e0 00 00:11:55.533 READ DMA EXT
25 03 f0 c2 85 50 e0 00 00:11:55.530 READ DMA EXT
25 03 10 43 a5 7a e0 00 00:11:55.529 READ DMA EXT
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 521 (0x0209)
Device State: Active (0)
Current Temperature: 34 Celsius
Power Cycle Min/Max Temperature: --/ 0 Celsius
Lifetime Min/Max Temperature: --/ 0 Celsius
SCT Data Table command not supported
SCT Error Recovery Control command not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
0x8002 2 0 Vendor specific
0x8003 2 3 Vendor specific
0x8004 2 0 Vendor specific