/dev/ada0
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Blue Mobile (SMR)
Device Model: WDC WD10SPZX-75Z10T2
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 03.01A03
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Form Factor: 2.5 inches
TRIM Command: Available, deterministic
Device is: In smartctl database 7.3/5528
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Jun 27 10:05:14 2024 IST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 3720) seconds.
Offline data collection
capabilities: (0x71) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 251) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x3035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 195 188 021 - 1250
4 Start_Stop_Count -O--CK 088 088 000 - 12549
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 081 081 000 - 14387
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 096 096 000 - 4632
191 G-Sense_Error_Rate -O--CK 001 001 000 - 8858
192 Power-Off_Retract_Count -O--CK 200 200 000 - 654
193 Load_Cycle_Count -O--CK 173 173 000 - 82563
194 Temperature_Celsius -O---K 112 094 000 - 31
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 2
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
240 Head_Flying_Hours -O--CK 087 087 000 - 9550
241 Total_LBAs_Written -O--CK 200 200 000 - 61069346886
242 Total_LBAs_Read -O--CK 200 200 000 - 79766661300
254 Free_Fall_Sensor -O--CK 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x24 GPL R/O 288 Current Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb6 GPL,SL VS 1 Device vendor specific log
0xb7 GPL,SL VS 74 Device vendor specific log
0xb9 GPL,SL VS 4 Device vendor specific log
0xbd GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 93 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Aborted by host 90% 14215 -
# 2 Short offline Completed without error 00% 13733 -
# 3 Short offline Interrupted (host reset) 80% 10636 -
# 4 Short offline Interrupted (host reset) 90% 10636 -
# 5 Short offline Interrupted (host reset) 90% 10635 -
# 6 Short offline Interrupted (host reset) 90% 10635 -
# 7 Short offline Interrupted (host reset) 90% 10632 -
# 8 Short offline Interrupted (host reset) 90% 10498 -
# 9 Short offline Aborted by host 90% 10421 -
#10 Short offline Aborted by host 90% 10258 -
#11 Short offline Aborted by host 90% 10258 -
#12 Short offline Aborted by host 90% 10258 -
#13 Short offline Interrupted (host reset) 90% 10215 -
#14 Short offline Aborted by host 90% 10214 -
#15 Short offline Aborted by host 90% 10076 -
#16 Short offline Interrupted (host reset) 90% 9874 -
#17 Short offline Aborted by host 90% 9567 -
#18 Short offline Aborted by host 90% 9183 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 31 Celsius
Power Cycle Min/Max Temperature: 30/32 Celsius
Lifetime Min/Max Temperature: 20/49 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (71)
Index Estimated Time Temperature Celsius
72 2024-06-27 07:58 30 ***********
... ..( 52 skipped). .. ***********
125 2024-06-27 08:51 30 ***********
126 2024-06-27 08:52 ? -
127 2024-06-27 08:53 30 ***********
0 2024-06-27 08:54 ? -
1 2024-06-27 08:55 30 ***********
2 2024-06-27 08:56 ? -
3 2024-06-27 08:57 30 ***********
4 2024-06-27 08:58 ? -
5 2024-06-27 08:59 30 ***********
6 2024-06-27 09:00 31 ************
... ..( 8 skipped). .. ************
15 2024-06-27 09:09 31 ************
16 2024-06-27 09:10 32 *************
... ..( 8 skipped). .. *************
25 2024-06-27 09:19 32 *************
26 2024-06-27 09:20 31 ************
... ..( 6 skipped). .. ************
33 2024-06-27 09:27 31 ************
34 2024-06-27 09:28 30 ***********
... ..( 22 skipped). .. ***********
57 2024-06-27 09:51 30 ***********
58 2024-06-27 09:52 31 ************
59 2024-06-27 09:53 31 ************
60 2024-06-27 09:54 31 ************
61 2024-06-27 09:55 ? -
62 2024-06-27 09:56 31 ************
... ..( 8 skipped). .. ************
71 2024-06-27 10:05 31 ************
SCT Error Recovery Control command not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 14 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 18 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 4054 Vendor specific
/dev/da0
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Samsung SpinPoint M8 (AF)
Device Model: ST1000LM024 HN-M101MBB
Serial Number: --
LU WWN Device Id: 5 0004cf ...
Firmware Version: 2AR10001
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Form Factor: 2.5 inches
Device is: In smartctl database 7.3/5528
ATA Version is: ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Thu Jun 27 10:05:14 2024 IST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unknown
=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 25) The self-test routine was aborted by
the host.
Total time to complete Offline
data collection: (13260) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 221) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 051 - 98
2 Throughput_Performance -OS--K 252 252 000 - 0
3 Spin_Up_Time PO---K 086 081 025 - 4458
4 Start_Stop_Count -O--CK 095 095 000 - 5572
5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0
7 Seek_Error_Rate -OSR-K 252 252 051 - 0
8 Seek_Time_Performance --S--K 252 252 015 - 0
9 Power_On_Hours -O--CK 100 100 000 - 3257
10 Spin_Retry_Count -O--CK 252 252 051 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 74
12 Power_Cycle_Count -O--CK 099 099 000 - 1691
191 G-Sense_Error_Rate -O---K 100 100 000 - 106
192 Power-Off_Retract_Count -O---K 252 252 000 - 0
194 Temperature_Celsius -O---- 061 037 000 - 39 (Min/Max 21/63)
195 Hardware_ECC_Recovered -O-RCK 100 100 000 - 0
196 Reallocated_Event_Count -O--CK 252 252 000 - 0
197 Current_Pending_Sector -O--CK 252 100 000 - 0
198 Offline_Uncorrectable ----CK 252 252 000 - 0
199 UDMA_CRC_Error_Count -OS-CK 200 200 000 - 0
200 Multi_Zone_Error_Rate -O-R-K 100 100 000 - 3762
223 Load_Retry_Count -O--CK 100 100 000 - 74
225 Load_Cycle_Count -O--CK 095 095 000 - 59387
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 2 Comprehensive SMART error log
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 2 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xc0-0xdf GPL,SL VS 16 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
Device Error Count: 91 (device log contains only the most recent 8 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 91 [2] occurred at disk power-on lifetime: 2252 hours (93 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 71 00 00 00 00 b8 70 40 00
Error: UNC 113 sectors at LBA = 0x0000b870 = 47216
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 71 00 00 00 00 b8 70 40 00 00:00:00.143 READ DMA EXT
25 00 00 00 01 00 00 00 00 b8 70 40 00 00:00:00.140 READ DMA EXT
e5 00 00 00 00 00 00 00 00 00 00 00 00 00:00:00.139 CHECK POWER MODE
25 00 00 00 01 00 00 00 00 b8 70 40 00 00:00:00.069 READ DMA EXT
25 00 00 00 6f 00 00 00 00 b8 72 40 00 00:00:00.067 READ DMA EXT
Error 90 [1] occurred at disk power-on lifetime: 2252 hours (93 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 00 00 b8 70 40 00
Error: UNC 1 sectors at LBA = 0x0000b870 = 47216
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 01 00 00 00 00 b8 70 40 00 00:00:00.140 READ DMA EXT
e5 00 00 00 00 00 00 00 00 00 00 00 00 00:00:00.139 CHECK POWER MODE
25 00 00 00 01 00 00 00 00 b8 70 40 00 00:00:00.069 READ DMA EXT
25 00 00 00 6f 00 00 00 00 b8 72 40 00 00:00:00.067 READ DMA EXT
25 00 00 00 70 00 00 00 00 b8 71 40 00 00:00:00.065 READ DMA EXT
Error 89 [0] occurred at disk power-on lifetime: 2252 hours (93 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 00 00 b8 70 40 00
Error: UNC 1 sectors at LBA = 0x0000b870 = 47216
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 01 00 00 00 00 b8 70 40 00 00:00:00.069 READ DMA EXT
25 00 00 00 6f 00 00 00 00 b8 72 40 00 00:00:00.067 READ DMA EXT
25 00 00 00 70 00 00 00 00 b8 71 40 00 00:00:00.065 READ DMA EXT
25 00 00 00 01 00 00 00 00 b8 70 40 00 00:00:00.061 READ DMA EXT
25 00 00 00 01 00 00 00 00 b8 70 40 00 00:00:00.049 READ DMA EXT
Error 88 [7] occurred at disk power-on lifetime: 2252 hours (93 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 6f 00 00 00 00 b8 72 40 00
Error: UNC 111 sectors at LBA = 0x0000b872 = 47218
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 6f 00 00 00 00 b8 72 40 00 00:00:00.067 READ DMA EXT
25 00 00 00 70 00 00 00 00 b8 71 40 00 00:00:00.065 READ DMA EXT
25 00 00 00 01 00 00 00 00 b8 70 40 00 00:00:00.061 READ DMA EXT
25 00 00 00 01 00 00 00 00 b8 70 40 00 00:00:00.049 READ DMA EXT
25 00 00 00 6f 00 00 00 00 b8 72 40 00 00:00:00.045 READ DMA EXT
Error 87 [6] occurred at disk power-on lifetime: 2252 hours (93 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 70 00 00 00 00 b8 71 40 00
Error: UNC 112 sectors at LBA = 0x0000b871 = 47217
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 70 00 00 00 00 b8 71 40 00 00:00:00.065 READ DMA EXT
25 00 00 00 01 00 00 00 00 b8 70 40 00 00:00:00.061 READ DMA EXT
25 00 00 00 01 00 00 00 00 b8 70 40 00 00:00:00.049 READ DMA EXT
25 00 00 00 6f 00 00 00 00 b8 72 40 00 00:00:00.045 READ DMA EXT
25 00 00 00 70 00 00 00 00 b8 71 40 00 00:00:00.043 READ DMA EXT
Error 86 [5] occurred at disk power-on lifetime: 2252 hours (93 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 00 00 b8 70 40 00
Error: UNC 1 sectors at LBA = 0x0000b870 = 47216
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 01 00 00 00 00 b8 70 40 00 00:00:00.061 READ DMA EXT
25 00 00 00 01 00 00 00 00 b8 70 40 00 00:00:00.049 READ DMA EXT
25 00 00 00 6f 00 00 00 00 b8 72 40 00 00:00:00.045 READ DMA EXT
25 00 00 00 70 00 00 00 00 b8 71 40 00 00:00:00.043 READ DMA EXT
25 00 00 00 01 00 00 00 00 b8 70 40 00 00:00:00.040 READ DMA EXT
Error 85 [4] occurred at disk power-on lifetime: 2252 hours (93 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 00 00 b8 70 40 00
Error: UNC 1 sectors at LBA = 0x0000b870 = 47216
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 01 00 00 00 00 b8 70 40 00 00:00:00.049 READ DMA EXT
25 00 00 00 6f 00 00 00 00 b8 72 40 00 00:00:00.045 READ DMA EXT
25 00 00 00 70 00 00 00 00 b8 71 40 00 00:00:00.043 READ DMA EXT
25 00 00 00 01 00 00 00 00 b8 70 40 00 00:00:00.040 READ DMA EXT
25 00 00 00 71 00 00 00 00 b8 70 40 00 00:00:00.036 READ DMA EXT
Error 84 [3] occurred at disk power-on lifetime: 2252 hours (93 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 6f 00 00 00 00 b8 72 40 00
Error: UNC 111 sectors at LBA = 0x0000b872 = 47218
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 6f 00 00 00 00 b8 72 40 00 00:00:00.045 READ DMA EXT
25 00 00 00 70 00 00 00 00 b8 71 40 00 00:00:00.043 READ DMA EXT
25 00 00 00 01 00 00 00 00 b8 70 40 00 00:00:00.040 READ DMA EXT
25 00 00 00 71 00 00 00 00 b8 70 40 00 00:00:00.036 READ DMA EXT
25 00 00 00 01 00 00 00 00 b8 70 40 00 00:00:00.033 READ DMA EXT
SMART Extended Self-test Log Version: 1 (2 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Aborted by host 60% 94 -
# 2 Short offline Completed without error 00% 92 -
# 3 Short offline Completed without error 00% 88 -
# 4 Short offline Completed without error 00% 87 -
# 5 Short offline Completed without error 00% 83 -
# 6 Short offline Completed without error 00% 82 -
# 7 Short offline Completed without error 00% 80 -
# 8 Short offline Completed without error 00% 80 -
# 9 Short offline Completed without error 00% 78 -
#10 Short offline Completed without error 00% 76 -
#11 Short offline Interrupted (host reset) 50% 76 -
#12 Short offline Completed without error 00% 75 -
#13 Short offline Completed without error 00% 69 -
#14 Short offline Completed without error 00% 67 -
#15 Short offline Completed without error 00% 65 -
#16 Short offline Completed without error 00% 63 -
#17 Short offline Completed without error 00% 58 -
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Aborted_by_host [90% left] (0-65535)
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 39 Celsius
Power Cycle Min/Max Temperature: 28/39 Celsius
Lifetime Min/Max Temperature: 21/64 Celsius
Specified Max Operating Temperature: 80 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 5 minutes
Temperature Logging Interval: 5 minutes
Min/Max recommended Temperature: -5/80 Celsius
Min/Max Temperature Limit: -10/85 Celsius
Temperature History Size (Index): 128 (126)
Index Estimated Time Temperature Celsius
127 2024-06-26 23:30 39 ********************
0 2024-06-26 23:35 35 ****************
1 2024-06-26 23:40 37 ******************
2 2024-06-26 23:45 38 *******************
3 2024-06-26 23:50 37 ******************
4 2024-06-26 23:55 36 *****************
5 2024-06-27 00:00 38 *******************
6 2024-06-27 00:05 38 *******************
7 2024-06-27 00:10 39 ********************
8 2024-06-27 00:15 40 *********************
9 2024-06-27 00:20 41 **********************
10 2024-06-27 00:25 42 ***********************
11 2024-06-27 00:30 44 *************************
... ..( 2 skipped). .. *************************
14 2024-06-27 00:45 44 *************************
15 2024-06-27 00:50 45 **************************
16 2024-06-27 00:55 46 ***************************
17 2024-06-27 01:00 47 ****************************
18 2024-06-27 01:05 43 ************************
19 2024-06-27 01:10 39 ********************
20 2024-06-27 01:15 38 *******************
21 2024-06-27 01:20 32 *************
22 2024-06-27 01:25 36 *****************
23 2024-06-27 01:30 39 ********************
24 2024-06-27 01:35 40 *********************
25 2024-06-27 01:40 42 ***********************
26 2024-06-27 01:45 43 ************************
27 2024-06-27 01:50 43 ************************
28 2024-06-27 01:55 44 *************************
29 2024-06-27 02:00 44 *************************
30 2024-06-27 02:05 43 ************************
31 2024-06-27 02:10 44 *************************
32 2024-06-27 02:15 32 *************
33 2024-06-27 02:20 37 ******************
34 2024-06-27 02:25 40 *********************
35 2024-06-27 02:30 44 *************************
36 2024-06-27 02:35 46 ***************************
37 2024-06-27 02:40 33 **************
38 2024-06-27 02:45 36 *****************
39 2024-06-27 02:50 38 *******************
40 2024-06-27 02:55 40 *********************
41 2024-06-27 03:00 41 **********************
42 2024-06-27 03:05 42 ***********************
43 2024-06-27 03:10 42 ***********************
44 2024-06-27 03:15 43 ************************
... ..( 2 skipped). .. ************************
47 2024-06-27 03:30 43 ************************
48 2024-06-27 03:35 42 ***********************
49 2024-06-27 03:40 41 **********************
50 2024-06-27 03:45 41 **********************
51 2024-06-27 03:50 42 ***********************
52 2024-06-27 03:55 42 ***********************
53 2024-06-27 04:00 43 ************************
54 2024-06-27 04:05 44 *************************
55 2024-06-27 04:10 43 ************************
56 2024-06-27 04:15 44 *************************
57 2024-06-27 04:20 44 *************************
58 2024-06-27 04:25 45 **************************
59 2024-06-27 04:30 42 ***********************
60 2024-06-27 04:35 43 ************************
61 2024-06-27 04:40 43 ************************
62 2024-06-27 04:45 44 *************************
63 2024-06-27 04:50 45 **************************
64 2024-06-27 04:55 33 **************
65 2024-06-27 05:00 34 ***************
... ..( 2 skipped). .. ***************
68 2024-06-27 05:15 34 ***************
69 2024-06-27 05:20 35 ****************
... ..( 2 skipped). .. ****************
72 2024-06-27 05:35 35 ****************
73 2024-06-27 05:40 34 ***************
74 2024-06-27 05:45 34 ***************
75 2024-06-27 05:50 35 ****************
... ..( 4 skipped). .. ****************
80 2024-06-27 06:15 35 ****************
81 2024-06-27 06:20 34 ***************
82 2024-06-27 06:25 34 ***************
83 2024-06-27 06:30 34 ***************
84 2024-06-27 06:35 35 ****************
85 2024-06-27 06:40 35 ****************
86 2024-06-27 06:45 34 ***************
87 2024-06-27 06:50 35 ****************
... ..( 10 skipped). .. ****************
98 2024-06-27 07:45 35 ****************
99 2024-06-27 07:50 30 ***********
100 2024-06-27 07:55 33 **************
101 2024-06-27 08:00 34 ***************
102 2024-06-27 08:05 35 ****************
103 2024-06-27 08:10 36 *****************
104 2024-06-27 08:15 36 *****************
105 2024-06-27 08:20 37 ******************
106 2024-06-27 08:25 38 *******************
107 2024-06-27 08:30 37 ******************
108 2024-06-27 08:35 37 ******************
109 2024-06-27 08:40 38 *******************
110 2024-06-27 08:45 34 ***************
111 2024-06-27 08:50 36 *****************
112 2024-06-27 08:55 37 ******************
113 2024-06-27 09:00 38 *******************
114 2024-06-27 09:05 39 ********************
115 2024-06-27 09:10 30 ***********
116 2024-06-27 09:15 32 *************
117 2024-06-27 09:20 33 **************
118 2024-06-27 09:25 34 ***************
119 2024-06-27 09:30 36 *****************
120 2024-06-27 09:35 37 ******************
121 2024-06-27 09:40 37 ******************
122 2024-06-27 09:45 38 *******************
123 2024-06-27 09:50 39 ********************
124 2024-06-27 09:55 39 ********************
125 2024-06-27 10:00 38 *******************
126 2024-06-27 10:05 39 ********************
SMART WRITE LOG does not return COUNT and LBA_LOW register
SCT (Get) Error Recovery Control command failed
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x0002 4 0 R_ERR response for data FIS
0x0003 4 0 R_ERR response for device-to-host data FIS
0x0004 4 0 R_ERR response for host-to-device data FIS
0x0005 4 0 R_ERR response for non-data FIS
0x0006 4 0 R_ERR response for device-to-host non-data FIS
0x0007 4 0 R_ERR response for host-to-device non-data FIS
0x0008 4 0 Device-to-host non-data FIS retries
0x0009 4 0 Transition from drive PhyRdy to drive PhyNRdy
0x000a 4 1 Device-to-host register FISes sent due to a COMRESET
0x000b 4 0 CRC errors within host-to-device FIS
0x000d 4 0 Non-CRC errors within host-to-device FIS
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC
0x8e00 4 0 Vendor specific
0x8e01 4 0 Vendor specific
0x8e02 4 0 Vendor specific
0x8e03 4 0 Vendor specific
0x8e04 4 0 Vendor specific
0x8e05 4 0 Vendor specific
0x8e06 4 0 Vendor specific
0x8e07 4 0 Vendor specific
0x8e08 4 0 Vendor specific
0x8e09 4 0 Vendor specific
0x8e0a 4 0 Vendor specific
0x8e0b 4 0 Vendor specific
0x8e0c 4 0 Vendor specific
0x8e0d 4 0 Vendor specific
0x8e0e 4 0 Vendor specific
0x8e0f 4 0 Vendor specific
0x8e10 4 0 Vendor specific
0x8e11 4 0 Vendor specific