/dev/sd0
smartctl 7.3 2022-02-28 r5338 [OpenBSD 7.1 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Momentus 7200.4
Device Model: ST9320423AS
Serial Number: --
LU WWN Device Id: 5 000c50 ...
Firmware Version: 0006HPM1
User Capacity: 320,072,933,376 bytes [320 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 7200 rpm
Form Factor: 2.5 inches
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Sun Aug 11 21:14:14 2024 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x53) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 78) minutes.
SCT capabilities: (0x103f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 110 090 006 Pre-fail Always - 27199421
3 Spin_Up_Time 0x0002 098 097 000 Old_age Always - 0
4 Start_Stop_Count 0x0033 097 097 000 Pre-fail Always - 4031
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0
7 Seek_Error_Rate 0x000f 078 060 030 Pre-fail Always - 39181022869
9 Power_On_Hours 0x0032 067 067 000 Old_age Always - 29362
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0033 097 037 020 Pre-fail Always - 4026
183 Runtime_Bad_Block 0x0032 100 253 000 Old_age Always - 0
184 End-to-End_Error 0x0033 100 100 097 Pre-fail Always - 0
187 Reported_Uncorrect 0x0032 001 001 000 Old_age Always - 368
188 Command_Timeout 0x0032 100 100 000 Old_age Always - 7
189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
190 Airflow_Temperature_Cel 0x0022 055 042 045 Old_age Always In_the_past 45 (Min/Max 27/45 #8)
191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 215
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 649
193 Load_Cycle_Count 0x0032 074 074 000 Old_age Always - 53048
194 Temperature_Celsius 0x0022 045 058 000 Old_age Always - 45 (0 5 0 0 0)
195 Hardware_ECC_Recovered 0x001a 052 048 000 Old_age Always - 27199421
196 Reallocated_Event_Count 0x0033 100 100 036 Pre-fail Always - 0
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
254 Free_Fall_Sensor 0x0032 100 100 000 Old_age Always - 0
SMART Error Log Version: 1
ATA Error Count: 270 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 270 occurred at disk power-on lifetime: 11339 hours (472 days + 11 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 10 c4 6a 00
Error: UNC at LBA = 0x006ac410 = 6997008
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 20 00 c4 6a 40 00 00:11:48.622 READ FPDMA QUEUED
ec 00 00 00 00 00 00 00 00:11:47.864 IDENTIFY DEVICE
ef 02 00 00 00 00 40 00 00:11:47.863 SET FEATURES [Enable write cache]
ef 03 45 00 00 00 40 00 00:11:47.832 SET FEATURES [Set transfer mode]
c6 00 10 00 00 00 40 00 00:11:47.618 SET MULTIPLE MODE
Error 269 occurred at disk power-on lifetime: 11339 hours (472 days + 11 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 10 c4 6a 00
Error: UNC at LBA = 0x006ac410 = 6997008
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 20 00 c4 6a 40 00 00:10:09.007 READ FPDMA QUEUED
2f 00 01 10 00 00 40 00 00:10:09.006 READ LOG EXT
60 00 20 00 c4 6a 40 00 00:10:06.341 READ FPDMA QUEUED
2f 00 01 10 00 00 40 00 00:10:06.341 READ LOG EXT
60 00 20 00 c4 6a 40 00 00:10:03.635 READ FPDMA QUEUED
Error 268 occurred at disk power-on lifetime: 11339 hours (472 days + 11 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 10 c4 6a 00
Error: UNC at LBA = 0x006ac410 = 6997008
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 20 00 c4 6a 40 00 00:10:06.341 READ FPDMA QUEUED
2f 00 01 10 00 00 40 00 00:10:06.341 READ LOG EXT
60 00 20 00 c4 6a 40 00 00:10:03.635 READ FPDMA QUEUED
2f 00 01 10 00 00 40 00 00:10:03.635 READ LOG EXT
60 00 20 00 c4 6a 40 00 00:10:01.020 READ FPDMA QUEUED
Error 267 occurred at disk power-on lifetime: 11339 hours (472 days + 11 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 10 c4 6a 00
Error: UNC at LBA = 0x006ac410 = 6997008
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 20 00 c4 6a 40 00 00:10:01.020 READ FPDMA QUEUED
2f 00 01 10 00 00 40 00 00:10:01.019 READ LOG EXT
60 00 20 00 c4 6a 40 00 00:09:58.391 READ FPDMA QUEUED
60 00 08 00 c4 6a 40 00 00:09:58.391 READ FPDMA QUEUED
60 00 08 70 68 a6 40 00 00:09:58.390 READ FPDMA QUEUED
Error 266 occurred at disk power-on lifetime: 11339 hours (472 days + 11 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 10 c4 6a 00
Error: UNC at LBA = 0x006ac410 = 6997008
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 20 00 c4 6a 40 00 00:09:58.391 READ FPDMA QUEUED
60 00 08 00 c4 6a 40 00 00:09:58.391 READ FPDMA QUEUED
60 00 08 70 68 a6 40 00 00:09:58.390 READ FPDMA QUEUED
60 00 08 a0 68 a6 40 00 00:09:58.389 READ FPDMA QUEUED
60 00 08 70 68 a6 40 00 00:09:58.389 READ FPDMA QUEUED
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 11371 -
# 2 Extended offline Interrupted (host reset) 90% 1 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.