Probe #d2e93eb2d7 of HP EliteBook 8440p

Log: smartctl

/dev/sd0 smartctl 7.3 2022-02-28 r5338 [OpenBSD 7.1 amd64] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Seagate Momentus 7200.4 Device Model: ST9320423AS Serial Number: -- LU WWN Device Id: 5 000c50 ... Firmware Version: 0006HPM1 User Capacity: 320,072,933,376 bytes [320 GB] Sector Size: 512 bytes logical/physical Rotation Rate: 7200 rpm Form Factor: 2.5 inches Device is: In smartctl database 7.3/5319 ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 2.6, 3.0 Gb/s Local Time is: Sun Aug 11 21:14:14 2024 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART Status not supported: Incomplete response, ATA output registers missing SMART overall-health self-assessment test result: PASSED Warning: This result is based on an Attribute check. See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x53) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 78) minutes. SCT capabilities: (0x103f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 110 090 006 Pre-fail Always - 27199421 3 Spin_Up_Time 0x0002 098 097 000 Old_age Always - 0 4 Start_Stop_Count 0x0033 097 097 000 Pre-fail Always - 4031 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 078 060 030 Pre-fail Always - 39181022869 9 Power_On_Hours 0x0032 067 067 000 Old_age Always - 29362 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0033 097 037 020 Pre-fail Always - 4026 183 Runtime_Bad_Block 0x0032 100 253 000 Old_age Always - 0 184 End-to-End_Error 0x0033 100 100 097 Pre-fail Always - 0 187 Reported_Uncorrect 0x0032 001 001 000 Old_age Always - 368 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 7 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 055 042 045 Old_age Always In_the_past 45 (Min/Max 27/45 #8) 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 215 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 649 193 Load_Cycle_Count 0x0032 074 074 000 Old_age Always - 53048 194 Temperature_Celsius 0x0022 045 058 000 Old_age Always - 45 (0 5 0 0 0) 195 Hardware_ECC_Recovered 0x001a 052 048 000 Old_age Always - 27199421 196 Reallocated_Event_Count 0x0033 100 100 036 Pre-fail Always - 0 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 254 Free_Fall_Sensor 0x0032 100 100 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 270 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 270 occurred at disk power-on lifetime: 11339 hours (472 days + 11 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 10 c4 6a 00 Error: UNC at LBA = 0x006ac410 = 6997008 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 00 20 00 c4 6a 40 00 00:11:48.622 READ FPDMA QUEUED ec 00 00 00 00 00 00 00 00:11:47.864 IDENTIFY DEVICE ef 02 00 00 00 00 40 00 00:11:47.863 SET FEATURES [Enable write cache] ef 03 45 00 00 00 40 00 00:11:47.832 SET FEATURES [Set transfer mode] c6 00 10 00 00 00 40 00 00:11:47.618 SET MULTIPLE MODE Error 269 occurred at disk power-on lifetime: 11339 hours (472 days + 11 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 10 c4 6a 00 Error: UNC at LBA = 0x006ac410 = 6997008 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 00 20 00 c4 6a 40 00 00:10:09.007 READ FPDMA QUEUED 2f 00 01 10 00 00 40 00 00:10:09.006 READ LOG EXT 60 00 20 00 c4 6a 40 00 00:10:06.341 READ FPDMA QUEUED 2f 00 01 10 00 00 40 00 00:10:06.341 READ LOG EXT 60 00 20 00 c4 6a 40 00 00:10:03.635 READ FPDMA QUEUED Error 268 occurred at disk power-on lifetime: 11339 hours (472 days + 11 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 10 c4 6a 00 Error: UNC at LBA = 0x006ac410 = 6997008 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 00 20 00 c4 6a 40 00 00:10:06.341 READ FPDMA QUEUED 2f 00 01 10 00 00 40 00 00:10:06.341 READ LOG EXT 60 00 20 00 c4 6a 40 00 00:10:03.635 READ FPDMA QUEUED 2f 00 01 10 00 00 40 00 00:10:03.635 READ LOG EXT 60 00 20 00 c4 6a 40 00 00:10:01.020 READ FPDMA QUEUED Error 267 occurred at disk power-on lifetime: 11339 hours (472 days + 11 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 10 c4 6a 00 Error: UNC at LBA = 0x006ac410 = 6997008 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 00 20 00 c4 6a 40 00 00:10:01.020 READ FPDMA QUEUED 2f 00 01 10 00 00 40 00 00:10:01.019 READ LOG EXT 60 00 20 00 c4 6a 40 00 00:09:58.391 READ FPDMA QUEUED 60 00 08 00 c4 6a 40 00 00:09:58.391 READ FPDMA QUEUED 60 00 08 70 68 a6 40 00 00:09:58.390 READ FPDMA QUEUED Error 266 occurred at disk power-on lifetime: 11339 hours (472 days + 11 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 10 c4 6a 00 Error: UNC at LBA = 0x006ac410 = 6997008 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 00 20 00 c4 6a 40 00 00:09:58.391 READ FPDMA QUEUED 60 00 08 00 c4 6a 40 00 00:09:58.391 READ FPDMA QUEUED 60 00 08 70 68 a6 40 00 00:09:58.390 READ FPDMA QUEUED 60 00 08 a0 68 a6 40 00 00:09:58.389 READ FPDMA QUEUED 60 00 08 70 68 a6 40 00 00:09:58.389 READ FPDMA QUEUED SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 11371 - # 2 Extended offline Interrupted (host reset) 90% 1 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.


Hardware for Linux and BSD

GitHub