Probe #c8b057c4e4 of Fujitsu D3313-B1 S26361-D331... Desktop Computer (FUTRO S720)

Log: smartctl

/dev/ada0 smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p12-HBSD amd64] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: SanDisk SSD P4 16GB Serial Number: -- LU WWN Device Id: 5 001b44 ... Firmware Version: SSD 8.13 User Capacity: 16,013,942,784 bytes [16.0 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 1.8 inches TRIM Command: Available Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ATA8-ACS T13/1699-D revision 2d SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s) Local Time is: Mon Oct 11 22:57:30 2021 BST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Unavailable === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 120) seconds. Offline data collection capabilities: (0x15) SMART execute Offline immediate. No Auto Offline data collection support. Abort Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 4) minutes. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 5 Reallocated_Sector_Ct -O---- 100 100 000 - 0 9 Power_On_Hours -O---- 100 100 000 - 3701 12 Power_Cycle_Count -O---- 100 100 000 - 937 171 Unknown_Attribute -O---- 100 100 000 - 0 172 Unknown_Attribute -O---- 100 100 000 - 0 173 Unknown_Attribute -O---- 100 100 000 - 19 174 Unknown_Attribute -O---- 100 100 000 - 116 187 Reported_Uncorrect -O---- 100 100 000 - 4 199 UDMA_CRC_Error_Count -O---- 100 100 000 - 0 230 Unknown_SSD_Attribute -O---- 000 100 000 - 0 232 Available_Reservd_Space PO---- 100 100 005 - 0 241 Total_LBAs_Written -O---- 100 100 000 - 805322041 242 Total_LBAs_Read -O---- 100 100 000 - 488650371 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x03 GPL,SL R/O 16 Ext. Comprehensive SMART error log 0x06 GPL,SL R/O 1 SMART self-test log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log Warning! SMART Extended Comprehensive Error Log Structure error: invalid SMART checksum. SMART Extended Comprehensive Error Log Version: 1 (16 sectors) No Errors Logged SMART Extended Self-test Log (GP Log 0x07) not supported SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] Selective Self-tests/Logging not supported SCT Commands not supported Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) not supported


Hardware for Linux and BSD

GitHub