Probe #c5a88098ff of Dell 0654JC A02 Desktop Computer (OptiPlex 5060)

Log: smartctl

/dev/ada0 smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p3 amd64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: SK hynix SATA SSDs Device Model: SK hynix SC308 SATA 256GB Serial Number: -- Firmware Version: 30000P10 User Capacity: 256,060,514,304 bytes [256 GB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: Solid State Device Form Factor: M.2 TRIM Command: Available, deterministic Device is: In smartctl database 7.3/5528 ATA Version is: ACS-2 (minor revision not indicated) SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Sat Oct 14 09:45:09 2023 MST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Disabled Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Unavailable === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x02) Offline data collection activity was completed without error. Auto Offline Data Collection: Disabled. Self-test execution status: ( 36) The self-test routine was interrupted by the host with a hard or soft reset. Total time to complete Offline data collection: ( 104) seconds. Offline data collection capabilities: (0x19) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0002) Does not save SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 20) minutes. SMART Attributes Data Structure revision number: 0 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-- 166 166 006 - 0 5 Retired_Block_Count -O--CK 253 100 036 - 0 9 Power_On_Hours -O--CK 071 071 000 - 25819 12 Power_Cycle_Count -O--CK 100 100 020 - 1691 100 Total_Erase_Count -O--CK 099 099 000 - 54540980 171 Program_Fail_Count -O--CK 253 253 000 - 0 172 Erase_Fail_Count -O--CK 253 253 000 - 0 174 Unexpect_Power_Loss_Ct ----CK 100 100 000 - 274 175 Program_Fail_Count_Chip -O--CK 253 253 000 - 0 176 Unused_Rsvd_Blk_Cnt_Tot -O--CK 253 253 000 - 0 177 Wear_Leveling_Count -O--CK 023 023 000 - 827 178 Used_Rsvd_Blk_Cnt_Chip -O--CK 100 100 000 - 30 179 Used_Rsvd_Blk_Cnt_Tot -O--CK 100 100 000 - 224 180 Erase_Fail_Count -O--CK 100 100 000 - 5216 181 Non4k_Aligned_Access -O--CK 253 253 000 - 0 182 Erase_Fail_Count_Total -O--CK 253 253 000 - 0 183 SATA_Downshift_Count -O--CK 253 253 000 - 0 187 Reported_Uncorrect -O--CK 253 253 000 - 0 188 Command_Timeout -O--CK 253 253 000 - 0 191 Unknown_SK_hynix_Attrib -O--CK 253 253 000 - 0 194 Temperature_Celsius -O---- 038 000 000 - 38 (Min/Max 0/68) 195 Hardware_ECC_Recovered -O--CK 253 253 000 - 0 199 UDMA_CRC_Error_Count -O--CK 253 253 000 - 0 201 Percent_Lifetime_Remain -OSR-- 100 100 000 - 0 204 Soft_ECC_Correction -OSR-- 001 001 000 - 53117 231 SSD_Life_Left PO--CK 023 023 010 - 78 234 Unknown_SK_hynix_Attrib -O--CK 100 100 000 - 448842600704 241 Total_Writes_GB -O--CK 100 100 000 - 49428435024 242 Total_Reads_GB -O--CK 100 100 000 - 26301635266 250 Read_Retry_Count -O--CK 100 100 000 - 28507238 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 4 Comprehensive SMART error log 0x03 GPL R/O 5 Ext. Comprehensive SMART error log 0x04 GPL,SL R/O 8 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 2 Extended self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x30 GPL R/O 8 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log SMART Extended Comprehensive Error Log Version: 1 (5 sectors) Device Error Count: 2 CR = Command Register FEATR = Features Register COUNT = Count (was: Sector Count) Register LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8 LH = LBA High (was: Cylinder High) Register ] LBA LM = LBA Mid (was: Cylinder Low) Register ] Register LL = LBA Low (was: Sector Number) Register ] DV = Device (was: Device/Head) Register DC = Device Control Register ER = Error register ST = Status register Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 2 [1] occurred at disk power-on lifetime: 6487 hours (270 days + 7 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 10 -- 51 00 00 00 00 00 00 00 00 e0 00 Error: IDNF Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- b0 00 d5 00 01 00 00 00 c2 4f e0 00 00 00:00:52.950 SMART READ LOG 20 00 00 00 01 00 00 00 00 00 00 40 40 00:00:52.950 READ SECTOR(S) b0 00 d5 00 01 00 00 00 c2 4f 9a 00 00 00:00:52.950 SMART READ LOG ec 00 00 00 01 00 00 00 00 00 00 40 40 00:00:52.950 IDENTIFY DEVICE ec 00 00 00 00 00 00 00 00 00 00 00 00 00:00:50.580 IDENTIFY DEVICE Error 1 [0] occurred at disk power-on lifetime: 6485 hours (270 days + 5 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 10 -- 51 00 00 00 00 00 00 00 00 e0 00 Error: IDNF Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- b0 00 d5 00 01 00 00 00 c2 4f e0 00 00 00:01:14.630 SMART READ LOG 20 00 00 00 01 00 00 00 00 00 00 40 40 00:01:14.630 READ SECTOR(S) b0 00 d5 00 01 00 00 00 c2 4f 9a 00 00 00:01:14.630 SMART READ LOG ec 00 00 00 01 00 00 00 00 00 00 40 40 00:01:14.630 IDENTIFY DEVICE ec 00 00 00 00 00 00 00 00 00 00 00 00 00:01:13.850 IDENTIFY DEVICE SMART Extended Self-test Log Version: 1 (2 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 90% 7826 - # 2 Extended offline Aborted by host 80% 6487 - # 3 Short offline Aborted by host 20% 6487 - # 4 Short offline Completed without error 00% 6485 - # 5 Short offline Completed without error 00% 0 - Selective Self-tests/Logging not supported SCT Commands not supported Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (empty) == 0x04 ===== = = === == General Errors Statistics (empty) == 0x05 ===== = = === == Temperature Statistics (empty) == 0x06 ===== = = === == Transport Statistics (empty) == 0x07 ===== = = === == Solid State Device Statistics (empty) == |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x000a 2 1931 Device-to-host register FISes sent due to a COMRESET


Hardware for Linux and BSD

GitHub