Probe #bbeb7d48fa of System76 Lemur Pro

Log: smartctl

/dev/ada0 smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RC2 amd64] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Crucial/Micron Client SSDs Device Model: Micron_1100_MTFDDAV256TBN Serial Number: -- LU WWN Device Id: 5 00a075 ... Firmware Version: M0MA020 User Capacity: 256,060,514,304 bytes [256 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: < 1.8 inches TRIM Command: Available, deterministic, zeroed Device is: In smartctl database 7.3/5319 ATA Version is: ACS-3 T13/2161-D revision 5 SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Sun Apr 17 10:06:35 2022 NZST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM level is: 254 (maximum performance) Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x03) Offline data collection activity is in progress. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 528) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 4) minutes. Conveyance self-test routine recommended polling time: ( 3) minutes. SCT capabilities: (0x0035) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0 5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0 9 Power_On_Hours -O--CK 100 100 000 - 3250 12 Power_Cycle_Count -O--CK 100 100 000 - 5582 171 Program_Fail_Count -O--CK 100 100 000 - 0 172 Erase_Fail_Count -O--CK 100 100 000 - 0 173 Ave_Block-Erase_Count -O--CK 094 094 000 - 104 174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 31 183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0 184 Error_Correction_Count -O--CK 100 100 000 - 0 187 Reported_Uncorrect -O--CK 100 100 000 - 0 194 Temperature_Celsius -O---K 062 042 000 - 38 (Min/Max 8/58) 196 Reallocated_Event_Count -O--CK 100 100 000 - 0 197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0 198 Offline_Uncorrectable ----CK 100 100 000 - 0 199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0 202 Percent_Lifetime_Remain ----CK 094 094 001 - 6 206 Write_Error_Rate -OSR-- 100 100 000 - 0 246 Total_LBAs_Written -O--CK 100 100 000 - 26999179587 247 Host_Program_Page_Count -O--CK 100 100 000 - 846095119 248 FTL_Program_Page_Count -O--CK 100 100 000 - 233326517 180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2043 210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 51 Comprehensive SMART error log 0x03 GPL R/O 16383 Ext. Comprehensive SMART error log 0x04 GPL,SL R/O 8 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x13 GPL R/O 1 SATA NCQ Send and Receive log 0x24 GPL R/O 8000 Current Device Internal Status Data log 0x25 GPL R/O 8000 Saved Device Internal Status Data log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0 GPL VS 35328 Device vendor specific log 0xa1 GPL,SL VS 3 Device vendor specific log 0xa2 GPL,SL VS 1 Device vendor specific log 0xa3 GPL VS 13824 Device vendor specific log 0xa4 GPL VS 354 Device vendor specific log 0xa4 SL VS 98 Device vendor specific log 0xa5 GPL VS 8000 Device vendor specific log 0xa5 SL VS 64 Device vendor specific log 0xa6 GPL VS 8000 Device vendor specific log 0xa6 SL VS 64 Device vendor specific log 0xa7-0xdf GPL,SL VS 1 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (16383 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Vendor (0xff) Completed without error 00% 3250 - # 2 Vendor (0xff) Completed without error 00% 3143 - # 3 Vendor (0xff) Completed without error 00% 3053 - # 4 Vendor (0xff) Completed without error 00% 2996 - # 5 Vendor (0xff) Completed without error 00% 2741 - # 6 Vendor (0xff) Completed without error 00% 2616 - # 7 Vendor (0xff) Completed without error 00% 2515 - # 8 Vendor (0xff) Completed without error 00% 2447 - # 9 Vendor (0xff) Completed without error 00% 2408 - #10 Vendor (0xff) Completed without error 00% 2279 - #11 Vendor (0xff) Completed without error 00% 2196 - #12 Vendor (0xff) Completed without error 00% 2101 - #13 Vendor (0xff) Completed without error 00% 1964 - #14 Vendor (0xff) Completed without error 00% 1895 - #15 Vendor (0xff) Completed without error 00% 1816 - #16 Vendor (0xff) Completed without error 00% 1739 - #17 Vendor (0xff) Completed without error 00% 1645 - #18 Vendor (0xff) Completed without error 00% 1502 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 1 (0x0001) Device State: SMART Off-line Data Collection executing in background (4) Current Temperature: 38 Celsius Power Cycle Min/Max Temperature: 29/52 Celsius Lifetime Min/Max Temperature: 8/58 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/70 Celsius Min/Max Temperature Limit: -5/75 Celsius Temperature History Size (Index): 478 (310) Index Estimated Time Temperature Celsius 311 2022-04-17 02:09 38 ******************* ... ..(165 skipped). .. ******************* 477 2022-04-17 04:55 38 ******************* 0 2022-04-17 04:56 30 *********** 1 2022-04-17 04:57 31 ************ 2 2022-04-17 04:58 31 ************ 3 2022-04-17 04:59 30 *********** ... ..( 2 skipped). .. *********** 6 2022-04-17 05:02 30 *********** 7 2022-04-17 05:03 31 ************ 8 2022-04-17 05:04 30 *********** ... ..( 44 skipped). .. *********** 53 2022-04-17 05:49 30 *********** 54 2022-04-17 05:50 31 ************ 55 2022-04-17 05:51 31 ************ 56 2022-04-17 05:52 32 ************* ... ..( 7 skipped). .. ************* 64 2022-04-17 06:00 32 ************* 65 2022-04-17 06:01 31 ************ ... ..( 11 skipped). .. ************ 77 2022-04-17 06:13 31 ************ 78 2022-04-17 06:14 30 *********** ... ..(132 skipped). .. *********** 211 2022-04-17 08:27 30 *********** 212 2022-04-17 08:28 39 ******************** 213 2022-04-17 08:29 44 ************************* 214 2022-04-17 08:30 45 ************************** 215 2022-04-17 08:31 46 *************************** 216 2022-04-17 08:32 46 *************************** 217 2022-04-17 08:33 46 *************************** 218 2022-04-17 08:34 42 *********************** 219 2022-04-17 08:35 40 ********************* 220 2022-04-17 08:36 40 ********************* 221 2022-04-17 08:37 39 ******************** ... ..( 44 skipped). .. ******************** 266 2022-04-17 09:22 39 ******************** 267 2022-04-17 09:23 38 ******************* ... ..( 9 skipped). .. ******************* 277 2022-04-17 09:33 38 ******************* 278 2022-04-17 09:34 39 ******************** 279 2022-04-17 09:35 39 ******************** 280 2022-04-17 09:36 38 ******************* ... ..( 29 skipped). .. ******************* 310 2022-04-17 10:06 38 ******************* SCT Error Recovery Control command not supported Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 1) == 0x01 0x008 4 5582 --- Lifetime Power-On Resets 0x01 0x010 4 3250 --- Power-on Hours 0x01 0x018 6 26999179587 --- Logical Sectors Written 0x01 0x020 6 460188759 --- Number of Write Commands 0x01 0x028 6 33275689378 --- Logical Sectors Read 0x01 0x030 6 617942810 --- Number of Read Commands 0x04 ===== = = === == General Errors Statistics (rev 1) == 0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors 0x04 0x010 4 5618 --- Resets Between Cmd Acceptance and Completion 0x05 ===== = = === == Temperature Statistics (rev 1) == 0x05 0x008 1 38 --- Current Temperature 0x05 0x010 1 37 --- Average Short Term Temperature 0x05 0x018 1 37 --- Average Long Term Temperature 0x05 0x020 1 58 --- Highest Temperature 0x05 0x028 1 8 --- Lowest Temperature 0x05 0x030 1 48 --- Highest Average Short Term Temperature 0x05 0x038 1 32 --- Lowest Average Short Term Temperature 0x05 0x040 1 44 --- Highest Average Long Term Temperature 0x05 0x048 1 37 --- Lowest Average Long Term Temperature 0x05 0x050 4 0 --- Time in Over-Temperature 0x05 0x058 1 70 --- Specified Maximum Operating Temperature 0x05 0x060 4 0 --- Time in Under-Temperature 0x05 0x068 1 0 --- Specified Minimum Operating Temperature 0x06 ===== = = === == Transport Statistics (rev 1) == 0x06 0x008 4 41741 --- Number of Hardware Resets 0x06 0x010 4 198 --- Number of ASR Events 0x06 0x018 4 0 --- Number of Interface CRC Errors 0x07 ===== = = === == Solid State Device Statistics (rev 1) == 0x07 0x008 1 6 N-- Percentage Used Endurance Indicator |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 4 0 Command failed due to ICRC error 0x000a 4 28 Device-to-host register FISes sent due to a COMRESET /dev/nvd0 smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RC2 amd64] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Number: Samsung SSD 970 EVO 500GB Serial Number: -- Firmware Version: 2B2QEXE7 PCI Vendor/Subsystem ID: 0x144d IEEE OUI Identifier: 0x002538 Total NVM Capacity: 500,107,862,016 [500 GB] Unallocated NVM Capacity: 0 Controller ID: 4 NVMe Version: 1.3 Number of Namespaces: 1 Namespace 1 Size/Capacity: 500,107,862,016 [500 GB] Namespace 1 Utilization: 435,641,401,344 [435 GB] Namespace 1 Formatted LBA Size: 512 Namespace 1 IEEE EUI-64: 002538 ... Local Time is: Sun Apr 17 10:06:35 2022 NZST Firmware Updates (0x16): 3 Slots, no Reset required Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg Maximum Data Transfer Size: 512 Pages Warning Comp. Temp. Threshold: 85 Celsius Critical Comp. Temp. Threshold: 85 Celsius Supported Power States St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat 0 + 6.20W - - 0 0 0 0 0 0 1 + 4.30W - - 1 1 1 1 0 0 2 + 2.10W - - 2 2 2 2 0 0 3 - 0.0400W - - 3 3 3 3 210 1200 4 - 0.0050W - - 4 4 4 4 2000 8000 Supported LBA Sizes (NSID 0x1) Id Fmt Data Metadt Rel_Perf 0 + 512 0 0 === START OF SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED SMART/Health Information (NVMe Log 0x02) Critical Warning: 0x00 Temperature: 36 Celsius Available Spare: 100% Available Spare Threshold: 10% Percentage Used: 0% Data Units Read: 2,239,138 [1.14 TB] Data Units Written: 3,951,273 [2.02 TB] Host Read Commands: 52,960,428 Host Write Commands: 117,175,468 Controller Busy Time: 228 Power Cycles: 493 Power On Hours: 2,335 Unsafe Shutdowns: 34 Media and Data Integrity Errors: 0 Error Information Log Entries: 26 Warning Comp. Temperature Time: 0 Critical Comp. Temperature Time: 0 Temperature Sensor 1: 36 Celsius Temperature Sensor 2: 45 Celsius Error Information (NVMe Log 0x01, 16 of 64 entries) No Errors Logged


Hardware for Linux and BSD

GitHub