Probe #a74913bffa of ASUSTek ROG STRIX B550-F GAM... Desktop Computer

Log: smartctl

/dev/ada0 smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Crucial/Micron Client SSDs Device Model: CT240BX500SSD1 Serial Number: -- LU WWN Device Id: 0 000000 ... Firmware Version: M6CR013 User Capacity: 240,057,409,536 bytes [240 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches TRIM Command: Available, deterministic, zeroed Device is: In smartctl database 7.3/5319 ATA Version is: ACS-2 T13/2015-D revision 3 SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Mon May 23 17:54:34 2022 EDT SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM level is: 254 (maximum performance) Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Unavailable === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 120) seconds. Offline data collection capabilities: (0x11) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0002) Does not save SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 10) minutes. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0 5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0 9 Power_On_Hours -O--CK 100 100 050 - 10689 12 Power_Cycle_Count -O--CK 100 100 050 - 6612 171 Program_Fail_Count -O--CK 100 100 050 - 0 172 Erase_Fail_Count -O--CK 100 100 050 - 0 173 Ave_Block-Erase_Count -O--CK 100 100 050 - 201 174 Unexpect_Power_Loss_Ct -O--CK 100 100 050 - 5431 180 Unused_Reserve_NAND_Blk -O--CK 100 100 050 - 100 183 SATA_Interfac_Downshift -O--CK 100 100 050 - 0 184 Error_Correction_Count -O--CK 100 100 050 - 0 187 Reported_Uncorrect -O--CK 100 100 050 - 0 194 Temperature_Celsius -O---K 061 025 050 Past 39 (Min/Max 20/75) 196 Reallocated_Event_Count -O--CK 100 100 050 - 0 197 Current_Pending_ECC_Cnt -O--CK 100 100 050 - 0 198 Offline_Uncorrectable ----CK 100 100 050 - 0 199 UDMA_CRC_Error_Count -O--CK 100 100 050 - 2 202 Percent_Lifetime_Remain ----CK 087 087 001 - 87 206 Write_Error_Rate -OSR-K 100 100 050 - 0 210 Success_RAIN_Recov_Cnt -O--CK 100 100 050 - 0 246 Total_LBAs_Written -O--CK 100 100 050 - 40806419898 247 Host_Program_Page_Count -O--CK 100 100 050 - 1275200621 248 FTL_Program_Page_Count -O--CK 100 100 050 - 1391141104 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 1 Comprehensive SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x04 GPL,SL R/O 8 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x24 GPL R/O 88 Current Device Internal Status Data log 0x25 GPL R/O 32 Saved Device Internal Status Data log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log SMART Extended Comprehensive Error Log Version: 1 (1 sectors) Invalid Error Log index = 0x0000 (reserved = 0x00) SMART Extended Self-test Log Version: 1 (1 sectors) No self-tests have been logged. [To run self-tests, use: smartctl -t] Selective Self-tests/Logging not supported SCT Commands not supported Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 1) == 0x01 0x008 4 6612 --- Lifetime Power-On Resets 0x01 0x010 4 10689 --- Power-on Hours 0x01 0x018 6 2151714234 --- Logical Sectors Written 0x01 0x020 6 525977895 --- Number of Write Commands 0x01 0x028 6 2711726364 --- Logical Sectors Read 0x01 0x030 6 614403986 --- Number of Read Commands 0x07 ===== = = === == Solid State Device Statistics (rev 1) == 0x07 0x008 1 23 --- Percentage Used Endurance Indicator |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 4 0 Command failed due to ICRC error 0x0002 4 0 R_ERR response for data FIS 0x0005 4 0 R_ERR response for non-data FIS 0x000a 4 15 Device-to-host register FISes sent due to a COMRESET /dev/ada1 smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Silicon Motion based SSDs Device Model: ADATA SU650 Serial Number: -- LU WWN Device Id: 5 000000 ... Firmware Version: S210712b User Capacity: 240,057,409,536 bytes [240 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches TRIM Command: Available, deterministic, zeroed Device is: In smartctl database 7.3/5319 ATA Version is: ACS-4 (minor revision not indicated) SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Mon May 23 17:54:34 2022 EDT SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 33) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 2) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x0031) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 0 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 9 Power_On_Hours -O--C- 100 100 000 - 948 12 Power_Cycle_Count -O--C- 100 100 000 - 195 167 Average_Erase_Count -O---K 100 100 000 - 0 168 Max_Erase_Count_of_Spec -O--C- 100 100 000 - 524288 169 Remaining_Lifetime_Perc PO--C- 099 099 010 - 131076 173 Unknown_Attribute -O--C- 200 200 000 - 30066933777 175 Program_Fail_Count_Chip PO--C- 100 100 010 - 0 180 Unused_Rsvd_Blk_Cnt_Tot PO--CK 100 100 020 - 342 192 Power-Off_Retract_Count -O--C- 100 100 000 - 89 194 Temperature_Celsius -O---K 069 069 030 - 31 (Min/Max 27/40) 231 SSD_Life_Left PO--CK 099 099 005 - 1 233 Media_Wearout_Indicator -O--CK 100 100 000 - 2157687296 234 Unknown_Attribute -O--CK 100 100 000 - 286982014464 241 Host_Writes_32MiB -O--CK 100 100 000 - 1571231146 242 Host_Reads_32MiB -O--CK 100 100 000 - 1408997443 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 51 Comprehensive SMART error log 0x03 GPL R/O 64 Ext. Comprehensive SMART error log 0x04 GPL,SL R/O 8 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (64 sectors) Device Error Count: 8 CR = Command Register FEATR = Features Register COUNT = Count (was: Sector Count) Register LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8 LH = LBA High (was: Cylinder High) Register ] LBA LM = LBA Mid (was: Cylinder Low) Register ] Register LL = LBA Low (was: Sector Number) Register ] DV = Device (was: Device/Head) Register DC = Device Control Register ER = Error register ST = Status register Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 8 [7] occurred at disk power-on lifetime: 449 hours (18 days + 17 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 10 -- 41 00 08 00 00 1c ec 60 00 40 00 Error: IDNF at LBA = 0x1cec6000 = 485253120 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 08 00 10 00 00 1c ec 60 00 40 80 00:02:08.700 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 e0 80 00:02:08.200 READ LOG EXT 60 00 07 00 08 00 00 1c ec 60 00 40 80 00:02:08.200 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 e0 80 00:02:07.700 READ LOG EXT 60 00 06 00 f8 00 00 1c ec 60 00 40 80 00:02:07.700 READ FPDMA QUEUED Error 7 [6] occurred at disk power-on lifetime: 449 hours (18 days + 17 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 10 -- 41 00 07 00 00 1c ec 60 00 40 00 Error: IDNF at LBA = 0x1cec6000 = 485253120 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 07 00 08 00 00 1c ec 60 00 40 80 00:02:08.200 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 e0 80 00:02:07.700 READ LOG EXT 60 00 06 00 f8 00 00 1c ec 60 00 40 80 00:02:07.700 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 e0 80 00:02:07.200 READ LOG EXT 60 00 05 00 f0 00 00 1c ec 60 00 40 80 00:02:07.200 READ FPDMA QUEUED Error 6 [5] occurred at disk power-on lifetime: 449 hours (18 days + 17 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 10 -- 41 00 06 00 00 1c ec 60 00 40 00 Error: IDNF at LBA = 0x1cec6000 = 485253120 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 06 00 f8 00 00 1c ec 60 00 40 80 00:02:07.700 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 e0 80 00:02:07.200 READ LOG EXT 60 00 05 00 f0 00 00 1c ec 60 00 40 80 00:02:07.200 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 e0 80 00:02:06.700 READ LOG EXT 60 00 04 00 e8 00 00 1c ec 60 00 40 80 00:02:06.700 READ FPDMA QUEUED Error 5 [4] occurred at disk power-on lifetime: 449 hours (18 days + 17 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 10 -- 41 00 05 00 00 1c ec 60 00 40 00 Error: IDNF at LBA = 0x1cec6000 = 485253120 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 05 00 f0 00 00 1c ec 60 00 40 80 00:02:07.200 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 e0 80 00:02:06.700 READ LOG EXT 60 00 04 00 e8 00 00 1c ec 60 00 40 80 00:02:06.700 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 e0 80 00:02:06.200 READ LOG EXT 60 00 03 00 e0 00 00 1c ec 60 00 40 80 00:02:06.200 READ FPDMA QUEUED Error 4 [3] occurred at disk power-on lifetime: 449 hours (18 days + 17 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 10 -- 41 00 04 00 00 1c ec 60 00 40 00 Error: IDNF at LBA = 0x1cec6000 = 485253120 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 04 00 e8 00 00 1c ec 60 00 40 80 00:02:06.700 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 e0 80 00:02:06.200 READ LOG EXT 60 00 03 00 e0 00 00 1c ec 60 00 40 80 00:02:06.200 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 e0 80 00:02:05.700 READ LOG EXT 60 00 02 00 d8 00 00 1c ec 60 00 40 80 00:02:05.700 READ FPDMA QUEUED Error 3 [2] occurred at disk power-on lifetime: 449 hours (18 days + 17 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 10 -- 41 00 03 00 00 1c ec 60 00 40 00 Error: IDNF at LBA = 0x1cec6000 = 485253120 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 03 00 e0 00 00 1c ec 60 00 40 80 00:02:06.200 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 e0 80 00:02:05.700 READ LOG EXT 60 00 02 00 d8 00 00 1c ec 60 00 40 80 00:02:05.700 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 e0 80 00:02:05.200 READ LOG EXT 60 00 01 00 d0 00 00 1c ec 60 00 40 80 00:02:05.200 READ FPDMA QUEUED Error 2 [1] occurred at disk power-on lifetime: 449 hours (18 days + 17 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 10 -- 41 00 02 00 00 1c ec 60 00 40 00 Error: IDNF at LBA = 0x1cec6000 = 485253120 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 02 00 d8 00 00 1c ec 60 00 40 80 00:02:05.700 READ FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 10 e0 80 00:02:05.200 READ LOG EXT 60 00 01 00 d0 00 00 1c ec 60 00 40 80 00:02:05.200 READ FPDMA QUEUED b0 00 d0 00 00 00 00 00 c2 4f 00 a0 80 00:02:04.600 SMART READ DATA b0 00 da 00 00 00 00 00 c2 4f 00 a0 80 00:02:04.600 SMART RETURN STATUS Error 1 [0] occurred at disk power-on lifetime: 449 hours (18 days + 17 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 10 -- 41 00 01 00 00 1c ec 60 00 40 00 Error: IDNF at LBA = 0x1cec6000 = 485253120 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 60 00 01 00 d0 00 00 1c ec 60 00 40 80 00:02:05.200 READ FPDMA QUEUED b0 00 d0 00 00 00 00 00 c2 4f 00 a0 80 00:02:04.600 SMART READ DATA b0 00 da 00 00 00 00 00 c2 4f 00 a0 80 00:02:04.600 SMART RETURN STATUS ea 00 00 00 00 00 00 00 00 00 00 a0 80 00:02:04.500 FLUSH CACHE EXT ea 00 00 00 00 00 00 00 00 00 00 a0 80 00:02:04.500 FLUSH CACHE EXT SMART Extended Self-test Log Version: 1 (1 sectors) No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 1 (0x0001) Device State: Active (0) Current Temperature: 33 Celsius Power Cycle Min/Max Temperature: ?/33 Celsius Lifetime Min/Max Temperature: ?/ ? Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: -127/127 Celsius Min/Max Temperature Limit: -127/127 Celsius Temperature History Size (Index): 478 (105) Index Estimated Time Temperature Celsius 106 2022-05-23 09:57 34 *************** 107 2022-05-23 09:58 35 **************** ... ..( 6 skipped). .. **************** 114 2022-05-23 10:05 35 **************** 115 2022-05-23 10:06 31 ************ 116 2022-05-23 10:07 35 **************** ... ..( 21 skipped). .. **************** 138 2022-05-23 10:29 35 **************** 139 2022-05-23 10:30 34 *************** 140 2022-05-23 10:31 35 **************** 141 2022-05-23 10:32 34 *************** 142 2022-05-23 10:33 35 **************** 143 2022-05-23 10:34 34 *************** ... ..( 8 skipped). .. *************** 152 2022-05-23 10:43 34 *************** 153 2022-05-23 10:44 35 **************** 154 2022-05-23 10:45 34 *************** 155 2022-05-23 10:46 35 **************** ... ..( 42 skipped). .. **************** 198 2022-05-23 11:29 35 **************** 199 2022-05-23 11:30 34 *************** 200 2022-05-23 11:31 35 **************** 201 2022-05-23 11:32 34 *************** ... ..( 8 skipped). .. *************** 210 2022-05-23 11:41 34 *************** 211 2022-05-23 11:42 35 **************** 212 2022-05-23 11:43 34 *************** ... ..( 6 skipped). .. *************** 219 2022-05-23 11:50 34 *************** 220 2022-05-23 11:51 35 **************** ... ..( 38 skipped). .. **************** 259 2022-05-23 12:30 35 **************** 260 2022-05-23 12:31 34 *************** 261 2022-05-23 12:32 35 **************** 262 2022-05-23 12:33 34 *************** ... ..( 12 skipped). .. *************** 275 2022-05-23 12:46 34 *************** 276 2022-05-23 12:47 ? - ... ..( 2 skipped). .. - 279 2022-05-23 12:50 ? - 280 2022-05-23 12:51 35 **************** ... ..( 2 skipped). .. **************** 283 2022-05-23 12:54 35 **************** 284 2022-05-23 12:55 36 ***************** ... ..( 6 skipped). .. ***************** 291 2022-05-23 13:02 36 ***************** 292 2022-05-23 13:03 37 ****************** 293 2022-05-23 13:04 35 **************** 294 2022-05-23 13:05 34 *************** 295 2022-05-23 13:06 36 ***************** 296 2022-05-23 13:07 ? - 297 2022-05-23 13:08 34 *************** 298 2022-05-23 13:09 ? - 299 2022-05-23 13:10 35 **************** ... ..( 2 skipped). .. **************** 302 2022-05-23 13:13 35 **************** 303 2022-05-23 13:14 36 ***************** 304 2022-05-23 13:15 37 ****************** 305 2022-05-23 13:16 36 ***************** 306 2022-05-23 13:17 39 ******************** 307 2022-05-23 13:18 39 ******************** 308 2022-05-23 13:19 ? - ... ..( 2 skipped). .. - 311 2022-05-23 13:22 ? - 312 2022-05-23 13:23 34 *************** 313 2022-05-23 13:24 33 ************** 314 2022-05-23 13:25 34 *************** 315 2022-05-23 13:26 33 ************** 316 2022-05-23 13:27 34 *************** ... ..( 18 skipped). .. *************** 335 2022-05-23 13:46 34 *************** 336 2022-05-23 13:47 ? - 337 2022-05-23 13:48 ? - 338 2022-05-23 13:49 34 *************** ... ..( 5 skipped). .. *************** 344 2022-05-23 13:55 34 *************** 345 2022-05-23 13:56 35 **************** ... ..( 9 skipped). .. **************** 355 2022-05-23 14:06 35 **************** 356 2022-05-23 14:07 34 *************** ... ..( 2 skipped). .. *************** 359 2022-05-23 14:10 34 *************** 360 2022-05-23 14:11 ? - 361 2022-05-23 14:12 34 *************** 362 2022-05-23 14:13 34 *************** 363 2022-05-23 14:14 33 ************** 364 2022-05-23 14:15 ? - 365 2022-05-23 14:16 ? - 366 2022-05-23 14:17 ? - 367 2022-05-23 14:18 34 *************** 368 2022-05-23 14:19 34 *************** 369 2022-05-23 14:20 35 **************** ... ..( 6 skipped). .. **************** 376 2022-05-23 14:27 35 **************** 377 2022-05-23 14:28 36 ***************** ... ..( 11 skipped). .. ***************** 389 2022-05-23 14:40 36 ***************** 390 2022-05-23 14:41 33 ************** 391 2022-05-23 14:42 ? - 392 2022-05-23 14:43 34 *************** 393 2022-05-23 14:44 33 ************** 394 2022-05-23 14:45 34 *************** 395 2022-05-23 14:46 33 ************** 396 2022-05-23 14:47 34 *************** 397 2022-05-23 14:48 ? - 398 2022-05-23 14:49 ? - 399 2022-05-23 14:50 34 *************** 400 2022-05-23 14:51 34 *************** 401 2022-05-23 14:52 34 *************** 402 2022-05-23 14:53 ? - 403 2022-05-23 14:54 33 ************** 404 2022-05-23 14:55 33 ************** 405 2022-05-23 14:56 ? - 406 2022-05-23 14:57 ? - 407 2022-05-23 14:58 34 *************** 408 2022-05-23 14:59 34 *************** 409 2022-05-23 15:00 32 ************* 410 2022-05-23 15:01 34 *************** 411 2022-05-23 15:02 34 *************** 412 2022-05-23 15:03 33 ************** 413 2022-05-23 15:04 ? - 414 2022-05-23 15:05 33 ************** 415 2022-05-23 15:06 ? - 416 2022-05-23 15:07 34 *************** 417 2022-05-23 15:08 34 *************** 418 2022-05-23 15:09 34 *************** 419 2022-05-23 15:10 35 **************** 420 2022-05-23 15:11 34 *************** 421 2022-05-23 15:12 35 **************** ... ..( 12 skipped). .. **************** 434 2022-05-23 15:25 35 **************** 435 2022-05-23 15:26 33 ************** 436 2022-05-23 15:27 35 **************** ... ..( 7 skipped). .. **************** 444 2022-05-23 15:35 35 **************** 445 2022-05-23 15:36 ? - 446 2022-05-23 15:37 ? - 447 2022-05-23 15:38 32 ************* 448 2022-05-23 15:39 ? - ... ..( 5 skipped). .. - 454 2022-05-23 15:45 ? - 455 2022-05-23 15:46 33 ************** ... ..( 9 skipped). .. ************** 465 2022-05-23 15:56 33 ************** 466 2022-05-23 15:57 34 *************** 467 2022-05-23 15:58 34 *************** 468 2022-05-23 15:59 33 ************** 469 2022-05-23 16:00 32 ************* 470 2022-05-23 16:01 34 *************** ... ..( 2 skipped). .. *************** 473 2022-05-23 16:04 34 *************** 474 2022-05-23 16:05 33 ************** 475 2022-05-23 16:06 33 ************** 476 2022-05-23 16:07 33 ************** 477 2022-05-23 16:08 34 *************** ... ..( 2 skipped). .. *************** 2 2022-05-23 16:11 34 *************** 3 2022-05-23 16:12 33 ************** 4 2022-05-23 16:13 34 *************** 5 2022-05-23 16:14 ? - 6 2022-05-23 16:15 34 *************** 7 2022-05-23 16:16 ? - 8 2022-05-23 16:17 ? - 9 2022-05-23 16:18 33 ************** 10 2022-05-23 16:19 33 ************** 11 2022-05-23 16:20 34 *************** 12 2022-05-23 16:21 34 *************** 13 2022-05-23 16:22 33 ************** 14 2022-05-23 16:23 34 *************** ... ..( 3 skipped). .. *************** 18 2022-05-23 16:27 34 *************** 19 2022-05-23 16:28 33 ************** 20 2022-05-23 16:29 34 *************** 21 2022-05-23 16:30 33 ************** 22 2022-05-23 16:31 34 *************** 23 2022-05-23 16:32 34 *************** 24 2022-05-23 16:33 33 ************** 25 2022-05-23 16:34 34 *************** ... ..( 6 skipped). .. *************** 32 2022-05-23 16:41 34 *************** 33 2022-05-23 16:42 33 ************** 34 2022-05-23 16:43 33 ************** 35 2022-05-23 16:44 34 *************** ... ..( 3 skipped). .. *************** 39 2022-05-23 16:48 34 *************** 40 2022-05-23 16:49 33 ************** 41 2022-05-23 16:50 34 *************** ... ..( 5 skipped). .. *************** 47 2022-05-23 16:56 34 *************** 48 2022-05-23 16:57 33 ************** 49 2022-05-23 16:58 34 *************** 50 2022-05-23 16:59 33 ************** ... ..( 6 skipped). .. ************** 57 2022-05-23 17:06 33 ************** 58 2022-05-23 17:07 39 ******************** 59 2022-05-23 17:08 33 ************** ... ..( 17 skipped). .. ************** 77 2022-05-23 17:26 33 ************** 78 2022-05-23 17:27 ? - 79 2022-05-23 17:28 33 ************** 80 2022-05-23 17:29 33 ************** 81 2022-05-23 17:30 33 ************** 82 2022-05-23 17:31 ? - 83 2022-05-23 17:32 32 ************* 84 2022-05-23 17:33 ? - ... ..( 19 skipped). .. - 104 2022-05-23 17:53 ? - 105 2022-05-23 17:54 33 ************** SCT Error Recovery Control command not supported Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 1) == 0x01 0x008 4 195 --- Lifetime Power-On Resets 0x01 0x010 4 948 --- Power-on Hours 0x01 0x018 6 1571231146 --- Logical Sectors Written 0x01 0x020 6 20238136 --- Number of Write Commands 0x01 0x028 6 1408997443 --- Logical Sectors Read 0x01 0x030 6 20435101 --- Number of Read Commands 0x01 0x038 6 870978262492 --- Date and Time TimeStamp 0x07 ===== = = === == Solid State Device Statistics (rev 1) == 0x07 0x008 1 4 N-- Percentage Used Endurance Indicator |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 8 Command failed due to ICRC error 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 4 0 Transition from drive PhyRdy to drive PhyNRdy 0x000a 4 16 Device-to-host register FISes sent due to a COMRESET 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC /dev/ada2 smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Blue Device Model: WDC WD10EZEX-08WN4A0 Serial Number: -- LU WWN Device Id: 5 0014ee ... Firmware Version: 02.01A02 User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Form Factor: 3.5 inches Device is: In smartctl database 7.3/5319 ATA Version is: ACS-3 T13/2161-D revision 3b SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Mon May 23 17:54:34 2022 EDT SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM level is: 128 (minimum power consumption without standby) Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (10800) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 113) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x3035) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0 3 Spin_Up_Time POS--K 190 169 021 - 1491 4 Start_Stop_Count -O--CK 096 096 000 - 4120 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 087 087 000 - 9492 10 Spin_Retry_Count -O--CK 100 100 000 - 0 11 Calibration_Retry_Count -O--CK 100 100 000 - 0 12 Power_Cycle_Count -O--CK 099 099 000 - 1641 192 Power-Off_Retract_Count -O--CK 200 200 000 - 628 193 Load_Cycle_Count -O--CK 195 195 000 - 15627 194 Temperature_Celsius -O---K 107 097 000 - 36 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 200 200 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 6 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log 0xa8-0xb6 GPL,SL VS 1 Device vendor specific log 0xb7 GPL,SL VS 48 Device vendor specific log 0xbd GPL,SL VS 1 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xc1 GPL VS 93 Device vendor specific log 0xdf GPL,SL VS 1 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (6 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 258 (0x0102) Device State: Active (0) Current Temperature: 36 Celsius Power Cycle Min/Max Temperature: 35/37 Celsius Lifetime Min/Max Temperature: 15/46 Celsius Under/Over Temperature Limit Count: 0/0 Vendor specific: 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -41/85 Celsius Temperature History Size (Index): 478 (455) Index Estimated Time Temperature Celsius 456 2022-05-23 09:57 36 ***************** ... ..( 14 skipped). .. ***************** 471 2022-05-23 10:12 36 ***************** 472 2022-05-23 10:13 37 ****************** ... ..( 32 skipped). .. ****************** 27 2022-05-23 10:46 37 ****************** 28 2022-05-23 10:47 ? - 29 2022-05-23 10:48 37 ****************** ... ..( 11 skipped). .. ****************** 41 2022-05-23 11:00 37 ****************** 42 2022-05-23 11:01 36 ***************** ... ..( 9 skipped). .. ***************** 52 2022-05-23 11:11 36 ***************** 53 2022-05-23 11:12 35 **************** ... ..( 5 skipped). .. **************** 59 2022-05-23 11:18 35 **************** 60 2022-05-23 11:19 36 ***************** 61 2022-05-23 11:20 36 ***************** 62 2022-05-23 11:21 36 ***************** 63 2022-05-23 11:22 37 ****************** ... ..( 11 skipped). .. ****************** 75 2022-05-23 11:34 37 ****************** 76 2022-05-23 11:35 36 ***************** ... ..( 14 skipped). .. ***************** 91 2022-05-23 11:50 36 ***************** 92 2022-05-23 11:51 35 **************** ... ..( 6 skipped). .. **************** 99 2022-05-23 11:58 35 **************** 100 2022-05-23 11:59 ? - 101 2022-05-23 12:00 35 **************** 102 2022-05-23 12:01 35 **************** 103 2022-05-23 12:02 35 **************** 104 2022-05-23 12:03 ? - 105 2022-05-23 12:04 35 **************** ... ..( 11 skipped). .. **************** 117 2022-05-23 12:16 35 **************** 118 2022-05-23 12:17 36 ***************** ... ..( 18 skipped). .. ***************** 137 2022-05-23 12:36 36 ***************** 138 2022-05-23 12:37 37 ****************** ... ..(109 skipped). .. ****************** 248 2022-05-23 14:27 37 ****************** 249 2022-05-23 14:28 36 ***************** ... ..( 6 skipped). .. ***************** 256 2022-05-23 14:35 36 ***************** 257 2022-05-23 14:36 37 ****************** ... ..( 6 skipped). .. ****************** 264 2022-05-23 14:43 37 ****************** 265 2022-05-23 14:44 36 ***************** ... ..( 22 skipped). .. ***************** 288 2022-05-23 15:07 36 ***************** 289 2022-05-23 15:08 37 ****************** 290 2022-05-23 15:09 36 ***************** ... ..( 23 skipped). .. ***************** 314 2022-05-23 15:33 36 ***************** 315 2022-05-23 15:34 35 **************** ... ..( 10 skipped). .. **************** 326 2022-05-23 15:45 35 **************** 327 2022-05-23 15:46 36 ***************** 328 2022-05-23 15:47 35 **************** 329 2022-05-23 15:48 35 **************** 330 2022-05-23 15:49 35 **************** 331 2022-05-23 15:50 36 ***************** ... ..( 34 skipped). .. ***************** 366 2022-05-23 16:25 36 ***************** 367 2022-05-23 16:26 37 ****************** ... ..( 4 skipped). .. ****************** 372 2022-05-23 16:31 37 ****************** 373 2022-05-23 16:32 36 ***************** ... ..( 3 skipped). .. ***************** 377 2022-05-23 16:36 36 ***************** 378 2022-05-23 16:37 31 ************ 379 2022-05-23 16:38 31 ************ 380 2022-05-23 16:39 32 ************* ... ..( 6 skipped). .. ************* 387 2022-05-23 16:46 32 ************* 388 2022-05-23 16:47 33 ************** ... ..( 8 skipped). .. ************** 397 2022-05-23 16:56 33 ************** 398 2022-05-23 16:57 34 *************** ... ..( 9 skipped). .. *************** 408 2022-05-23 17:07 34 *************** 409 2022-05-23 17:08 35 **************** ... ..( 36 skipped). .. **************** 446 2022-05-23 17:45 35 **************** 447 2022-05-23 17:46 36 ***************** ... ..( 7 skipped). .. ***************** 455 2022-05-23 17:54 36 ***************** SCT Error Recovery Control command not supported Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 15 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 17 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x8000 4 16587 Vendor specific /dev/nvd0 smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Number: HP SSD EX900 500GB Serial Number: -- Firmware Version: T0609B0L PCI Vendor/Subsystem ID: 0x1dee IEEE OUI Identifier: 0x000000 Total NVM Capacity: 500,107,862,016 [500 GB] Unallocated NVM Capacity: 0 Controller ID: 1 NVMe Version: 1.3 Number of Namespaces: 1 Namespace 1 Size/Capacity: 500,107,862,016 [500 GB] Namespace 1 Formatted LBA Size: 512 Local Time is: Mon May 23 17:54:34 2022 EDT Firmware Updates (0x12): 1 Slot, no Reset required Optional Admin Commands (0x0007): Security Format Frmw_DL Optional NVM Commands (0x0015): Comp DS_Mngmt Sav/Sel_Feat Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg Maximum Data Transfer Size: 64 Pages Warning Comp. Temp. Threshold: 83 Celsius Critical Comp. Temp. Threshold: 85 Celsius Supported Power States St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat 0 + 6.00W - - 0 0 0 0 0 0 Supported LBA Sizes (NSID 0x1) Id Fmt Data Metadt Rel_Perf 0 + 512 0 0 === START OF SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED SMART/Health Information (NVMe Log 0x02) Critical Warning: 0x00 Temperature: 32 Celsius Available Spare: 100% Available Spare Threshold: 10% Percentage Used: 0% Data Units Read: 9,780,990 [5.00 TB] Data Units Written: 9,101,058 [4.65 TB] Host Read Commands: 114,003,570 Host Write Commands: 126,551,749 Controller Busy Time: 6,639 Power Cycles: 381 Power On Hours: 1,609 Unsafe Shutdowns: 127 Media and Data Integrity Errors: 0 Error Information Log Entries: 0 Warning Comp. Temperature Time: 0 Critical Comp. Temperature Time: 0 Error Information (NVMe Log 0x01, 16 of 64 entries) No Errors Logged /dev/nvd1 smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Number: Seagate BarraCuda Q5 ZP500CV30001 Serial Number: -- Firmware Version: SU5SH017 PCI Vendor/Subsystem ID: 0x1bb1 IEEE OUI Identifier: 0x6479a7 Total NVM Capacity: 500,107,862,016 [500 GB] Unallocated NVM Capacity: 0 Controller ID: 1 NVMe Version: 1.3 Number of Namespaces: 1 Namespace 1 Size/Capacity: 500,107,862,016 [500 GB] Namespace 1 Formatted LBA Size: 512 Namespace 1 IEEE EUI-64: 6479a7 ... Local Time is: Mon May 23 17:54:34 2022 EDT Firmware Updates (0x16): 3 Slots, no Reset required Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp Log Page Attributes (0x0e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Maximum Data Transfer Size: 64 Pages Warning Comp. Temp. Threshold: 70 Celsius Critical Comp. Temp. Threshold: 85 Celsius Supported Power States St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat 0 + 3.50W - - 0 0 0 0 0 0 1 + 1.90W - - 1 1 1 1 0 0 2 + 1.50W - - 2 2 2 2 0 0 3 - 0.0700W - - 3 3 3 3 5000 1900 4 - 0.0020W - - 4 4 4 4 13000 100000 Supported LBA Sizes (NSID 0x1) Id Fmt Data Metadt Rel_Perf 0 + 512 0 1 1 - 4096 0 0 === START OF SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED SMART/Health Information (NVMe Log 0x02) Critical Warning: 0x00 Temperature: 32 Celsius Available Spare: 100% Available Spare Threshold: 5% Percentage Used: 2% Data Units Read: 8,232,835 [4.21 TB] Data Units Written: 5,724,690 [2.93 TB] Host Read Commands: 53,544,843 Host Write Commands: 34,676,259 Controller Busy Time: 762 Power Cycles: 553 Power On Hours: 2,532 Unsafe Shutdowns: 165 Media and Data Integrity Errors: 0 Error Information Log Entries: 3,058 Warning Comp. Temperature Time: 0 Critical Comp. Temperature Time: 0 Error Information (NVMe Log 0x01, 16 of 16 entries) No Errors Logged


Hardware for Linux and BSD

GitHub