/dev/ada0
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p4 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Red
Device Model: WDC WD40EFRX-68WT0N0
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 82.00A82
User Capacity: 4,000,787,030,016 bytes [4.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Device is: In smartctl database 7.3/5528
ATA Version is: ACS-2 (minor revision not indicated)
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Oct 12 09:21:12 2023 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (52320) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 523) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x703d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 214 178 021 - 6275
4 Start_Stop_Count -O--CK 100 100 000 - 123
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 016 016 000 - 61715
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 123
192 Power-Off_Retract_Count -O--CK 200 200 000 - 86
193 Load_Cycle_Count -O--CK 188 188 000 - 38989
194 Temperature_Celsius -O---K 122 113 000 - 30
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb6 GPL,SL VS 1 Device vendor specific log
0xb7 GPL,SL VS 39 Device vendor specific log
0xbd GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 93 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
Device Error Count: 3
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 3 [2] occurred at disk power-on lifetime: 27145 hours (1131 days + 1 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 36 a9 fa 10 40 00
Error: UNC at LBA = 0x36a9fa10 = 917109264
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 58 00 00 36 a9 fa 10 40 08 9d+18:02:08.607 READ FPDMA QUEUED
60 00 08 00 50 00 00 36 a9 78 80 40 08 9d+18:02:08.605 READ FPDMA QUEUED
60 00 08 00 48 00 00 36 a8 f8 70 40 08 9d+18:02:08.601 READ FPDMA QUEUED
60 00 08 00 40 00 00 36 a8 b8 e0 40 08 9d+18:02:08.597 READ FPDMA QUEUED
60 00 08 00 38 00 00 36 a8 77 58 40 08 9d+18:02:08.594 READ FPDMA QUEUED
Error 2 [1] occurred at disk power-on lifetime: 27145 hours (1131 days + 1 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 01 6d 5f ca 30 40 00
Error: UNC at LBA = 0x16d5fca30 = 6129961520
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 28 00 78 00 01 6d 5f ca 30 40 08 9d+17:54:44.796 READ FPDMA QUEUED
60 00 28 00 70 00 01 6d 5f c8 b0 40 08 9d+17:54:44.787 READ FPDMA QUEUED
60 00 08 00 68 00 01 6b 0f 02 88 40 08 9d+17:54:44.785 READ FPDMA QUEUED
60 00 08 00 60 00 01 6b 0e fb 58 40 08 9d+17:54:44.778 READ FPDMA QUEUED
60 00 08 00 58 00 01 6b 0e f9 20 40 08 9d+17:54:44.775 READ FPDMA QUEUED
Error 1 [0] occurred at disk power-on lifetime: 17338 hours (722 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 ab 2e 11 c8 40 00
Error: WP at LBA = 0xab2e11c8 = 2871923144
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 80 00 28 00 01 c3 ff 8e 60 40 08 25d+06:27:30.878 WRITE FPDMA QUEUED
60 01 00 00 20 00 00 ab 2e 15 78 40 08 25d+06:27:30.878 READ FPDMA QUEUED
60 00 80 00 18 00 00 ab 2e 12 48 40 08 25d+06:27:30.878 READ FPDMA QUEUED
61 01 00 00 10 00 01 c3 ff 8d 60 40 08 25d+06:27:30.878 WRITE FPDMA QUEUED
60 01 00 00 08 00 00 ab 2e 11 48 40 08 25d+06:27:30.878 READ FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 30 Celsius
Power Cycle Min/Max Temperature: 30/35 Celsius
Lifetime Min/Max Temperature: 23/40 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (323)
Index Estimated Time Temperature Celsius
324 2023-10-12 01:24 32 *************
... ..( 36 skipped). .. *************
361 2023-10-12 02:01 32 *************
362 2023-10-12 02:02 33 **************
... ..( 7 skipped). .. **************
370 2023-10-12 02:10 33 **************
371 2023-10-12 02:11 34 ***************
... ..( 19 skipped). .. ***************
391 2023-10-12 02:31 34 ***************
392 2023-10-12 02:32 35 ****************
... ..( 8 skipped). .. ****************
401 2023-10-12 02:41 35 ****************
402 2023-10-12 02:42 34 ***************
... ..( 2 skipped). .. ***************
405 2023-10-12 02:45 34 ***************
406 2023-10-12 02:46 33 **************
... ..( 20 skipped). .. **************
427 2023-10-12 03:07 33 **************
428 2023-10-12 03:08 32 *************
... ..( 71 skipped). .. *************
22 2023-10-12 04:20 32 *************
23 2023-10-12 04:21 31 ************
... ..( 27 skipped). .. ************
51 2023-10-12 04:49 31 ************
52 2023-10-12 04:50 32 *************
... ..( 22 skipped). .. *************
75 2023-10-12 05:13 32 *************
76 2023-10-12 05:14 31 ************
... ..( 52 skipped). .. ************
129 2023-10-12 06:07 31 ************
130 2023-10-12 06:08 30 ***********
... ..(124 skipped). .. ***********
255 2023-10-12 08:13 30 ***********
256 2023-10-12 08:14 32 *************
... ..( 66 skipped). .. *************
323 2023-10-12 09:21 32 *************
SCT Error Recovery Control:
Read: 70 (7.0 seconds)
Write: 70 (7.0 seconds)
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 159822 Vendor specific
/dev/ada1
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p4 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Red
Device Model: WDC WD40EFRX-68WT0N0
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 80.00A80
User Capacity: 4,000,787,030,016 bytes [4.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Device is: In smartctl database 7.3/5528
ATA Version is: ACS-2 (minor revision not indicated)
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Oct 12 09:21:12 2023 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (50580) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 506) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x703d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 212 175 021 - 6391
4 Start_Stop_Count -O--CK 100 100 000 - 166
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 002 002 000 - 72124
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 166
192 Power-Off_Retract_Count -O--CK 200 200 000 - 114
193 Load_Cycle_Count -O--CK 198 198 000 - 7709
194 Temperature_Celsius -O---K 120 110 000 - 32
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
0xbd GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 93 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
Device Error Count: 4
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 4 [3] occurred at disk power-on lifetime: 37578 hours (1565 days + 18 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 36 73 fc 68 40 00
Error: UNC at LBA = 0x3673fc68 = 913570920
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 c0 00 00 36 73 fc 68 40 08 9d+18:04:42.934 READ FPDMA QUEUED
60 00 08 00 b8 00 00 36 73 7b d0 40 08 9d+18:04:42.922 READ FPDMA QUEUED
60 00 08 00 b0 00 00 36 73 3a c8 40 08 9d+18:04:42.915 READ FPDMA QUEUED
60 00 08 00 a8 00 00 36 72 3b 90 40 08 9d+18:04:42.909 READ FPDMA QUEUED
60 00 08 00 a0 00 00 36 71 fe 08 40 08 9d+18:04:42.903 READ FPDMA QUEUED
Error 3 [2] occurred at disk power-on lifetime: 37578 hours (1565 days + 18 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 01 55 d1 ba 48 40 00
Error: UNC at LBA = 0x155d1ba48 = 5734775368
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 40 00 01 55 d1 c1 d0 40 08 9d+17:57:19.127 READ FPDMA QUEUED
60 00 18 00 38 00 01 55 d1 ba 48 40 08 9d+17:57:19.127 READ FPDMA QUEUED
60 00 28 00 30 00 01 55 c6 1d d8 40 08 9d+17:57:19.121 READ FPDMA QUEUED
60 00 20 00 28 00 01 55 c6 1a d0 40 08 9d+17:57:19.121 READ FPDMA QUEUED
60 00 08 00 20 00 01 55 c6 19 78 40 08 9d+17:57:19.103 READ FPDMA QUEUED
Error 2 [1] occurred at disk power-on lifetime: 27781 hours (1157 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 01 04 79 6d 07 40 00
Error: UNC at LBA = 0x104796d07 = 4370033927
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 80 00 38 00 01 04 79 6d 88 40 08 25d+17:16:05.744 READ FPDMA QUEUED
60 00 80 00 30 00 01 04 79 6d 08 40 08 25d+17:16:05.744 READ FPDMA QUEUED
60 00 80 00 28 00 01 04 79 6c 88 40 08 25d+17:16:05.744 READ FPDMA QUEUED
60 00 80 00 20 00 01 04 79 6c 08 40 08 25d+17:16:05.743 READ FPDMA QUEUED
60 01 00 00 18 00 01 04 79 6b 08 40 08 25d+17:16:05.742 READ FPDMA QUEUED
Error 1 [0] occurred at disk power-on lifetime: 27770 hours (1157 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 ab 2e 12 28 40 00
Error: WP at LBA = 0xab2e1228 = 2871923240
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 01 00 00 38 00 01 c3 ff 8d 60 40 08 25d+06:28:08.913 WRITE FPDMA QUEUED
61 01 00 00 30 00 01 c3 ff 8c 60 40 08 25d+06:28:08.913 WRITE FPDMA QUEUED
60 01 00 00 28 00 00 ab 2e 11 48 40 08 25d+06:28:08.913 READ FPDMA QUEUED
60 01 00 00 20 00 00 ab 2e 10 48 40 08 25d+06:28:08.913 READ FPDMA QUEUED
60 01 00 00 18 00 00 ab 2e 0f 48 40 08 25d+06:28:08.913 READ FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 32 Celsius
Power Cycle Min/Max Temperature: 31/37 Celsius
Lifetime Min/Max Temperature: 24/42 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (79)
Index Estimated Time Temperature Celsius
80 2023-10-12 01:24 34 ***************
... ..( 5 skipped). .. ***************
86 2023-10-12 01:30 34 ***************
87 2023-10-12 01:31 33 **************
... ..(178 skipped). .. **************
266 2023-10-12 04:30 33 **************
267 2023-10-12 04:31 32 *************
... ..(115 skipped). .. *************
383 2023-10-12 06:27 32 *************
384 2023-10-12 06:28 33 **************
... ..(100 skipped). .. **************
7 2023-10-12 08:09 33 **************
8 2023-10-12 08:10 34 ***************
... ..( 2 skipped). .. ***************
11 2023-10-12 08:13 34 ***************
12 2023-10-12 08:14 35 ****************
... ..( 5 skipped). .. ****************
18 2023-10-12 08:20 35 ****************
19 2023-10-12 08:21 36 *****************
... ..( 13 skipped). .. *****************
33 2023-10-12 08:35 36 *****************
34 2023-10-12 08:36 37 ******************
... ..( 20 skipped). .. ******************
55 2023-10-12 08:57 37 ******************
56 2023-10-12 08:58 36 *****************
... ..( 4 skipped). .. *****************
61 2023-10-12 09:03 36 *****************
62 2023-10-12 09:04 35 ****************
... ..( 7 skipped). .. ****************
70 2023-10-12 09:12 35 ****************
71 2023-10-12 09:13 34 ***************
... ..( 7 skipped). .. ***************
79 2023-10-12 09:21 34 ***************
SCT Error Recovery Control:
Read: 70 (7.0 seconds)
Write: 70 (7.0 seconds)
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 159824 Vendor specific
/dev/ada2
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p4 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Red
Device Model: WDC WD40EFRX-68WT0N0
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 80.00A80
User Capacity: 4,000,787,030,016 bytes [4.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Device is: In smartctl database 7.3/5528
ATA Version is: ACS-2 (minor revision not indicated)
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Oct 12 09:21:12 2023 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (53460) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 534) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x703d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 215 180 021 - 6225
4 Start_Stop_Count -O--CK 100 100 000 - 165
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 002 002 000 - 72124
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 165
192 Power-Off_Retract_Count -O--CK 200 200 000 - 113
193 Load_Cycle_Count -O--CK 198 198 000 - 7703
194 Temperature_Celsius -O---K 121 112 000 - 31
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
0xbd GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 93 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
Device Error Count: 2
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 2 [1] occurred at disk power-on lifetime: 37577 hours (1565 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 36 8a 0e c0 40 00
Error: UNC at LBA = 0x368a0ec0 = 915017408
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 b0 00 00 36 8a fb f8 40 08 9d+18:03:46.484 READ FPDMA QUEUED
60 00 08 00 a8 00 00 36 8a bc f0 40 08 9d+18:03:46.477 READ FPDMA QUEUED
60 00 08 00 a0 00 00 36 8a 0e c0 40 08 9d+18:03:46.473 READ FPDMA QUEUED
60 00 08 00 98 00 00 36 89 ce 30 40 08 9d+18:03:46.468 READ FPDMA QUEUED
60 00 08 00 90 00 00 36 89 48 20 40 08 9d+18:03:46.466 READ FPDMA QUEUED
Error 1 [0] occurred at disk power-on lifetime: 37577 hours (1565 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 01 55 c6 19 70 40 00
Error: UNC at LBA = 0x155c61970 = 5734013296
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 38 00 d8 00 01 55 c6 19 70 40 08 9d+17:56:22.675 READ FPDMA QUEUED
60 00 08 00 d0 00 01 55 c6 16 60 40 08 9d+17:56:22.671 READ FPDMA QUEUED
60 00 18 00 c8 00 01 02 bf 55 20 40 08 9d+17:56:22.662 READ FPDMA QUEUED
60 00 18 00 c0 00 01 02 bf 52 b0 40 08 9d+17:56:22.653 READ FPDMA QUEUED
60 00 08 00 b8 00 00 f3 2a 48 60 40 08 9d+17:56:22.648 READ FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 31 Celsius
Power Cycle Min/Max Temperature: 30/36 Celsius
Lifetime Min/Max Temperature: 23/41 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (38)
Index Estimated Time Temperature Celsius
39 2023-10-12 01:24 33 **************
... ..( 24 skipped). .. **************
64 2023-10-12 01:49 33 **************
65 2023-10-12 01:50 32 *************
... ..(136 skipped). .. *************
202 2023-10-12 04:07 32 *************
203 2023-10-12 04:08 31 ************
... ..(138 skipped). .. ************
342 2023-10-12 06:27 31 ************
343 2023-10-12 06:28 32 *************
... ..( 96 skipped). .. *************
440 2023-10-12 08:05 32 *************
441 2023-10-12 08:06 33 **************
... ..( 8 skipped). .. **************
450 2023-10-12 08:15 33 **************
451 2023-10-12 08:16 34 ***************
... ..( 6 skipped). .. ***************
458 2023-10-12 08:23 34 ***************
459 2023-10-12 08:24 35 ****************
... ..( 17 skipped). .. ****************
477 2023-10-12 08:42 35 ****************
0 2023-10-12 08:43 36 *****************
... ..( 9 skipped). .. *****************
10 2023-10-12 08:53 36 *****************
11 2023-10-12 08:54 35 ****************
... ..( 3 skipped). .. ****************
15 2023-10-12 08:58 35 ****************
16 2023-10-12 08:59 34 ***************
... ..( 5 skipped). .. ***************
22 2023-10-12 09:05 34 ***************
23 2023-10-12 09:06 33 **************
... ..( 14 skipped). .. **************
38 2023-10-12 09:21 33 **************
SCT Error Recovery Control:
Read: 70 (7.0 seconds)
Write: 70 (7.0 seconds)
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 159823 Vendor specific
/dev/ada3
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p4 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Samsung based SSDs
Device Model: Samsung SSD 860 EVO 1TB
Serial Number: --
LU WWN Device Id: 5 002538 ...
Firmware Version: RVT03B6Q
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database 7.3/5528
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Oct 12 09:21:12 2023 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x53) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 85) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 093 093 000 - 31508
12 Power_Cycle_Count -O--CK 099 099 000 - 31
177 Wear_Leveling_Count PO--C- 086 086 000 - 252
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O--CK 072 050 000 - 28
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 100 100 000 - 0
235 POR_Recovery_Count -O--C- 099 099 000 - 17
241 Total_LBAs_Written -O--CK 099 099 000 - 162061114353
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 1 Comprehensive SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 SL VS 16 Device vendor specific log
0xa5 SL VS 16 Device vendor specific log
0xce SL VS 16 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
256 0 65535 Read_scanning was never started
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 28 Celsius
Power Cycle Min/Max Temperature: 26/42 Celsius
Lifetime Min/Max Temperature: 22/50 Celsius
Specified Max Operating Temperature: 70 Celsius
Under/Over Temperature Limit Count: 0/0
SMART Status: 0xc24f (PASSED)
SCT Temperature History Version: 2
Temperature Sampling Period: 10 minutes
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (42)
Index Estimated Time Temperature Celsius
43 2023-10-11 12:10 29 **********
44 2023-10-11 12:20 40 *********************
45 2023-10-11 12:30 33 **************
46 2023-10-11 12:40 29 **********
47 2023-10-11 12:50 29 **********
48 2023-10-11 13:00 29 **********
49 2023-10-11 13:10 30 ***********
50 2023-10-11 13:20 29 **********
51 2023-10-11 13:30 29 **********
52 2023-10-11 13:40 30 ***********
53 2023-10-11 13:50 29 **********
54 2023-10-11 14:00 30 ***********
... ..( 4 skipped). .. ***********
59 2023-10-11 14:50 30 ***********
60 2023-10-11 15:00 29 **********
61 2023-10-11 15:10 29 **********
62 2023-10-11 15:20 29 **********
63 2023-10-11 15:30 32 *************
64 2023-10-11 15:40 33 **************
65 2023-10-11 15:50 30 ***********
66 2023-10-11 16:00 36 *****************
67 2023-10-11 16:10 29 **********
68 2023-10-11 16:20 30 ***********
69 2023-10-11 16:30 30 ***********
70 2023-10-11 16:40 29 **********
71 2023-10-11 16:50 29 **********
72 2023-10-11 17:00 30 ***********
73 2023-10-11 17:10 31 ************
74 2023-10-11 17:20 30 ***********
75 2023-10-11 17:30 41 **********************
76 2023-10-11 17:40 37 ******************
77 2023-10-11 17:50 42 ***********************
78 2023-10-11 18:00 30 ***********
79 2023-10-11 18:10 30 ***********
80 2023-10-11 18:20 29 **********
81 2023-10-11 18:30 30 ***********
82 2023-10-11 18:40 30 ***********
83 2023-10-11 18:50 35 ****************
84 2023-10-11 19:00 30 ***********
85 2023-10-11 19:10 31 ************
86 2023-10-11 19:20 30 ***********
87 2023-10-11 19:30 30 ***********
88 2023-10-11 19:40 29 **********
89 2023-10-11 19:50 31 ************
90 2023-10-11 20:00 31 ************
91 2023-10-11 20:10 31 ************
92 2023-10-11 20:20 34 ***************
93 2023-10-11 20:30 30 ***********
94 2023-10-11 20:40 30 ***********
95 2023-10-11 20:50 30 ***********
96 2023-10-11 21:00 32 *************
97 2023-10-11 21:10 29 **********
98 2023-10-11 21:20 31 ************
99 2023-10-11 21:30 29 **********
100 2023-10-11 21:40 29 **********
101 2023-10-11 21:50 29 **********
102 2023-10-11 22:00 38 *******************
103 2023-10-11 22:10 30 ***********
104 2023-10-11 22:20 29 **********
105 2023-10-11 22:30 28 *********
106 2023-10-11 22:40 29 **********
107 2023-10-11 22:50 28 *********
... ..( 26 skipped). .. *********
6 2023-10-12 03:20 28 *********
7 2023-10-12 03:30 35 ****************
8 2023-10-12 03:40 34 ***************
9 2023-10-12 03:50 29 **********
10 2023-10-12 04:00 29 **********
11 2023-10-12 04:10 28 *********
... ..( 2 skipped). .. *********
14 2023-10-12 04:40 28 *********
15 2023-10-12 04:50 29 **********
16 2023-10-12 05:00 28 *********
17 2023-10-12 05:10 28 *********
18 2023-10-12 05:20 29 **********
19 2023-10-12 05:30 28 *********
20 2023-10-12 05:40 29 **********
21 2023-10-12 05:50 28 *********
... ..( 3 skipped). .. *********
25 2023-10-12 06:30 28 *********
26 2023-10-12 06:40 27 ********
... ..( 5 skipped). .. ********
32 2023-10-12 07:40 27 ********
33 2023-10-12 07:50 26 *******
34 2023-10-12 08:00 27 ********
35 2023-10-12 08:10 27 ********
36 2023-10-12 08:20 26 *******
37 2023-10-12 08:30 27 ********
... ..( 4 skipped). .. ********
42 2023-10-12 09:20 27 ********
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 31 --- Lifetime Power-On Resets
0x01 0x010 4 31508 --- Power-on Hours
0x01 0x018 6 162061114353 --- Logical Sectors Written
0x01 0x020 6 2518307972 --- Number of Write Commands
0x01 0x028 6 75414517758 --- Logical Sectors Read
0x01 0x030 6 297387062 --- Number of Read Commands
0x01 0x038 6 3335000 --- Date and Time TimeStamp
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 28 --- Current Temperature
0x05 0x020 1 50 --- Highest Temperature
0x05 0x028 1 22 --- Lowest Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 3016 --- Number of Hardware Resets
0x06 0x010 4 0 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 14 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
/dev/nvd0
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p4 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Seagate FireCuda 520 SSD ZP500GM30002
Serial Number: --
Firmware Version: STNSC014
PCI Vendor/Subsystem ID: 0x1bb1
IEEE OUI Identifier: 0x0024cf
Total NVM Capacity: 500,107,862,016 [500 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 500,107,862,016 [500 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 0024cf ...
Local Time is: Thu Oct 12 09:21:12 2023 CEST
Firmware Updates (0x1e): 7 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005d): Comp DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x08): Telmtry_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 90 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 7.14W - - 0 0 0 0 0 0
1 + 5.43W - - 1 1 1 1 0 0
2 + 4.57W - - 2 2 2 2 0 0
3 - 0.0490W - - 3 3 3 3 2000 2000
4 - 0.0018W - - 4 4 4 4 25000 25000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 37 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 7%
Data Units Read: 6,578,625 [3.36 TB]
Data Units Written: 35,342,504 [18.0 TB]
Host Read Commands: 213,325,623
Host Write Commands: 1,160,191,867
Controller Busy Time: 3,504
Power Cycles: 18
Power On Hours: 19,695
Unsafe Shutdowns: 14
Media and Data Integrity Errors: 0
Error Information Log Entries: 57
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
Num Test_Description Status Power_on_Hours Failing_LBA NSID Seg SCT Code
0 Short Completed without error 13244 - - - - -