Probe #9e03a76684 of Acer Predator PH517-61

Log: smartctl

/dev/ada0 smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Black Mobile Device Model: WDC WD10JPLX-00MBPT1 Serial Number: -- LU WWN Device Id: 5 000cca ... Firmware Version: JB0OA3U0 User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Form Factor: 2.5 inches Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 6 SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Sat May 8 21:16:22 2021 EEST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM level is: 128 (minimum power consumption without standby) Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 45) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 169) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0 2 Throughput_Performance P-S--- 100 100 040 - 0 3 Spin_Up_Time POS--- 132 132 033 - 1 4 Start_Stop_Count -O--C- 099 099 000 - 1907 5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0 7 Seek_Error_Rate PO-R-- 100 100 067 - 0 8 Seek_Time_Performance P-S--- 100 100 040 - 0 9 Power_On_Hours -O--C- 094 094 000 - 2753 10 Spin_Retry_Count PO--C- 100 100 060 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 894 191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0 192 Power-Off_Retract_Count -O--CK 100 100 000 - 169 193 Load_Cycle_Count -O--C- 098 098 000 - 23472 194 Temperature_Celsius -O---- 187 187 000 - 32 (Min/Max 14/44) 196 Reallocated_Event_Count -O--CK 100 100 000 - 0 197 Current_Pending_Sector -O---K 100 100 000 - 0 198 Offline_Uncorrectable ---R-- 100 100 000 - 0 199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0 223 Load_Retry_Count -O-R-- 100 100 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 1 Comprehensive SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 256 (0x0100) Device State: Active (0) Current Temperature: 31 Celsius Power Cycle Min/Max Temperature: 31/32 Celsius Lifetime Min/Max Temperature: 14/44 Celsius Specified Max Operating Temperature: 31 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -40/65 Celsius Temperature History Size (Index): 128 (97) Index Estimated Time Temperature Celsius 98 2021-05-08 19:09 31 ************ ... ..( 18 skipped). .. ************ 117 2021-05-08 19:28 31 ************ 118 2021-05-08 19:29 ? - 119 2021-05-08 19:30 23 **** 120 2021-05-08 19:31 24 ***** 121 2021-05-08 19:32 24 ***** 122 2021-05-08 19:33 25 ****** 123 2021-05-08 19:34 25 ****** 124 2021-05-08 19:35 25 ****** 125 2021-05-08 19:36 26 ******* 126 2021-05-08 19:37 26 ******* 127 2021-05-08 19:38 26 ******* 0 2021-05-08 19:39 27 ******** ... ..( 4 skipped). .. ******** 5 2021-05-08 19:44 27 ******** 6 2021-05-08 19:45 28 ********* ... ..( 2 skipped). .. ********* 9 2021-05-08 19:48 28 ********* 10 2021-05-08 19:49 29 ********** ... ..( 12 skipped). .. ********** 23 2021-05-08 20:02 29 ********** 24 2021-05-08 20:03 30 *********** ... ..( 23 skipped). .. *********** 48 2021-05-08 20:27 30 *********** 49 2021-05-08 20:28 31 ************ 50 2021-05-08 20:29 30 *********** 51 2021-05-08 20:30 31 ************ ... ..( 10 skipped). .. ************ 62 2021-05-08 20:41 31 ************ 63 2021-05-08 20:42 32 ************* ... ..( 2 skipped). .. ************* 66 2021-05-08 20:45 32 ************* 67 2021-05-08 20:46 31 ************ 68 2021-05-08 20:47 32 ************* ... ..( 3 skipped). .. ************* 72 2021-05-08 20:51 32 ************* 73 2021-05-08 20:52 ? - 74 2021-05-08 20:53 32 ************* 75 2021-05-08 20:54 32 ************* 76 2021-05-08 20:55 31 ************ 77 2021-05-08 20:56 32 ************* 78 2021-05-08 20:57 31 ************ ... ..( 7 skipped). .. ************ 86 2021-05-08 21:05 31 ************ 87 2021-05-08 21:06 ? - 88 2021-05-08 21:07 31 ************ 89 2021-05-08 21:08 32 ************* 90 2021-05-08 21:09 31 ************ 91 2021-05-08 21:10 32 ************* 92 2021-05-08 21:11 32 ************* 93 2021-05-08 21:12 31 ************ 94 2021-05-08 21:13 32 ************* ... ..( 2 skipped). .. ************* 97 2021-05-08 21:16 32 ************* SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 3 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS /dev/ada1 smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Samsung based SSDs Device Model: Samsung SSD 860 EVO M.2 1TB Serial Number: -- LU WWN Device Id: 5 002538 ... Firmware Version: RVT24B6Q User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: M.2 TRIM Command: Available, deterministic, zeroed Device is: In smartctl database [for details use: -P show] ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5 SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Sat May 8 21:16:23 2021 EEST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x53) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 85) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0 9 Power_On_Hours -O--CK 099 099 000 - 2242 12 Power_Cycle_Count -O--CK 099 099 000 - 594 177 Wear_Leveling_Count PO--C- 099 099 000 - 7 179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0 181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0 182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0 183 Runtime_Bad_Block PO--C- 100 100 010 - 0 187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0 190 Airflow_Temperature_Cel -O--CK 055 036 000 - 45 195 ECC_Error_Rate -O-RC- 200 200 000 - 0 199 CRC_Error_Count -OSRCK 100 100 000 - 0 235 POR_Recovery_Count -O--C- 099 099 000 - 15 241 Total_LBAs_Written -O--CK 099 099 000 - 11519108487 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 1 Comprehensive SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x04 GPL,SL R/O 8 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x13 GPL R/O 1 SATA NCQ Send and Receive log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa1 SL VS 16 Device vendor specific log 0xa5 SL VS 16 Device vendor specific log 0xce SL VS 16 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing 256 0 65535 Read_scanning was never started Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 256 (0x0100) Device State: Active (0) Current Temperature: 45 Celsius Power Cycle Min/Max Temperature: 45/46 Celsius Lifetime Min/Max Temperature: 32/64 Celsius Specified Max Operating Temperature: 70 Celsius Under/Over Temperature Limit Count: 0/0 SMART Status: 0xc24f (PASSED) SCT Temperature History Version: 2 Temperature Sampling Period: 10 minutes Temperature Logging Interval: 10 minutes Min/Max recommended Temperature: 0/70 Celsius Min/Max Temperature Limit: 0/70 Celsius Temperature History Size (Index): 128 (107) Index Estimated Time Temperature Celsius 108 2021-05-08 00:00 45 ************************** ... ..( 2 skipped). .. ************************** 111 2021-05-08 00:30 45 ************************** 112 2021-05-08 00:40 44 ************************* 113 2021-05-08 00:50 ? - 114 2021-05-08 01:00 36 ***************** 115 2021-05-08 01:10 41 ********************** 116 2021-05-08 01:20 44 ************************* 117 2021-05-08 01:30 45 ************************** 118 2021-05-08 01:40 46 *************************** 119 2021-05-08 01:50 47 **************************** ... ..( 2 skipped). .. **************************** 122 2021-05-08 02:20 47 **************************** 123 2021-05-08 02:30 50 ******************************* 124 2021-05-08 02:40 47 **************************** 125 2021-05-08 02:50 47 **************************** 126 2021-05-08 03:00 47 **************************** 127 2021-05-08 03:10 48 ***************************** 0 2021-05-08 03:20 47 **************************** 1 2021-05-08 03:30 46 *************************** 2 2021-05-08 03:40 45 ************************** 3 2021-05-08 03:50 45 ************************** 4 2021-05-08 04:00 44 ************************* 5 2021-05-08 04:10 44 ************************* 6 2021-05-08 04:20 46 *************************** 7 2021-05-08 04:30 44 ************************* ... ..( 10 skipped). .. ************************* 18 2021-05-08 06:20 44 ************************* 19 2021-05-08 06:30 43 ************************ ... ..( 3 skipped). .. ************************ 23 2021-05-08 07:10 43 ************************ 24 2021-05-08 07:20 44 ************************* ... ..( 2 skipped). .. ************************* 27 2021-05-08 07:50 44 ************************* 28 2021-05-08 08:00 43 ************************ ... ..( 2 skipped). .. ************************ 31 2021-05-08 08:30 43 ************************ 32 2021-05-08 08:40 44 ************************* ... ..( 5 skipped). .. ************************* 38 2021-05-08 09:40 44 ************************* 39 2021-05-08 09:50 43 ************************ ... ..( 4 skipped). .. ************************ 44 2021-05-08 10:40 43 ************************ 45 2021-05-08 10:50 44 ************************* ... ..( 10 skipped). .. ************************* 56 2021-05-08 12:40 44 ************************* 57 2021-05-08 12:50 45 ************************** 58 2021-05-08 13:00 44 ************************* ... ..( 2 skipped). .. ************************* 61 2021-05-08 13:30 44 ************************* 62 2021-05-08 13:40 45 ************************** 63 2021-05-08 13:50 45 ************************** 64 2021-05-08 14:00 45 ************************** 65 2021-05-08 14:10 44 ************************* 66 2021-05-08 14:20 44 ************************* 67 2021-05-08 14:30 44 ************************* 68 2021-05-08 14:40 46 *************************** 69 2021-05-08 14:50 45 ************************** 70 2021-05-08 15:00 44 ************************* ... ..( 3 skipped). .. ************************* 74 2021-05-08 15:40 44 ************************* 75 2021-05-08 15:50 ? - 76 2021-05-08 16:00 38 ******************* 77 2021-05-08 16:10 42 *********************** 78 2021-05-08 16:20 43 ************************ 79 2021-05-08 16:30 44 ************************* ... ..( 2 skipped). .. ************************* 82 2021-05-08 17:00 44 ************************* 83 2021-05-08 17:10 45 ************************** 84 2021-05-08 17:20 ? - 85 2021-05-08 17:30 39 ******************** 86 2021-05-08 17:40 43 ************************ 87 2021-05-08 17:50 ? - 88 2021-05-08 18:00 45 ************************** 89 2021-05-08 18:10 44 ************************* 90 2021-05-08 18:20 44 ************************* 91 2021-05-08 18:30 45 ************************** 92 2021-05-08 18:40 45 ************************** 93 2021-05-08 18:50 53 ********************************** 94 2021-05-08 19:00 46 *************************** 95 2021-05-08 19:10 ? - 96 2021-05-08 19:20 37 ****************** 97 2021-05-08 19:30 41 ********************** 98 2021-05-08 19:40 42 *********************** 99 2021-05-08 19:50 43 ************************ 100 2021-05-08 20:00 44 ************************* ... ..( 2 skipped). .. ************************* 103 2021-05-08 20:30 44 ************************* 104 2021-05-08 20:40 ? - 105 2021-05-08 20:50 46 *************************** 106 2021-05-08 21:00 ? - 107 2021-05-08 21:10 45 ************************** SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 1) == 0x01 0x008 4 594 --- Lifetime Power-On Resets 0x01 0x010 4 2242 --- Power-on Hours 0x01 0x018 6 11519108487 --- Logical Sectors Written 0x01 0x020 6 90541360 --- Number of Write Commands 0x01 0x028 6 16798039995 --- Logical Sectors Read 0x01 0x030 6 268993604 --- Number of Read Commands 0x01 0x038 6 2180000 --- Date and Time TimeStamp 0x04 ===== = = === == General Errors Statistics (rev 1) == 0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors 0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion 0x05 ===== = = === == Temperature Statistics (rev 1) == 0x05 0x008 1 45 --- Current Temperature 0x05 0x020 1 64 --- Highest Temperature 0x05 0x028 1 32 --- Lowest Temperature 0x05 0x058 1 70 --- Specified Maximum Operating Temperature 0x06 ===== = = === == Transport Statistics (rev 1) == 0x06 0x008 4 1739 --- Number of Hardware Resets 0x06 0x010 4 0 --- Number of ASR Events 0x06 0x018 4 0 --- Number of Interface CRC Errors 0x07 ===== = = === == Solid State Device Statistics (rev 1) == 0x07 0x008 1 0 N-- Percentage Used Endurance Indicator |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 2 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC /dev/nvme0 smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Number: Samsung SSD 970 PRO 1TB Serial Number: -- Firmware Version: 1B2QEXP7 PCI Vendor/Subsystem ID: 0x144d IEEE OUI Identifier: 0x002538 Total NVM Capacity: 1,024,209,543,168 [1.02 TB] Unallocated NVM Capacity: 0 Controller ID: 4 NVMe Version: 1.3 Number of Namespaces: 1 Namespace 1 Size/Capacity: 1,024,209,543,168 [1.02 TB] Namespace 1 Utilization: 803,184,295,936 [803 GB] Namespace 1 Formatted LBA Size: 512 Namespace 1 IEEE EUI-64: 002538 ... Local Time is: Sat May 8 21:16:23 2021 EEST Firmware Updates (0x16): 3 Slots, no Reset required Optional Admin Commands (0x0037): Security Format Frmw_DL Self_Test Directvs Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg Maximum Data Transfer Size: 512 Pages Warning Comp. Temp. Threshold: 81 Celsius Critical Comp. Temp. Threshold: 81 Celsius Supported Power States St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat 0 + 6.20W - - 0 0 0 0 0 0 1 + 4.30W - - 1 1 1 1 0 0 2 + 2.10W - - 2 2 2 2 0 0 3 - 0.0400W - - 3 3 3 3 210 1200 4 - 0.0050W - - 4 4 4 4 2000 8000 Supported LBA Sizes (NSID 0x1) Id Fmt Data Metadt Rel_Perf 0 + 512 0 0 === START OF SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED SMART/Health Information (NVMe Log 0x02) Critical Warning: 0x00 Temperature: 47 Celsius Available Spare: 100% Available Spare Threshold: 10% Percentage Used: 1% Data Units Read: 27,131,323 [13.8 TB] Data Units Written: 72,250,140 [36.9 TB] Host Read Commands: 327,309,429 Host Write Commands: 540,260,608 Controller Busy Time: 852 Power Cycles: 608 Power On Hours: 1,705 Unsafe Shutdowns: 34 Media and Data Integrity Errors: 0 Error Information Log Entries: 908 Warning Comp. Temperature Time: 0 Critical Comp. Temperature Time: 0 Temperature Sensor 1: 47 Celsius Temperature Sensor 2: 52 Celsius Error Information (NVMe Log 0x01, 16 of 64 entries) No Errors Logged


Hardware for Linux and BSD

GitHub