Probe #9d393db103 of Lenovo ThinkPad X220 4291EM...
Log: smartctl
/dev/sd0c
smartctl 7.1 2019-12-30 r5022 [x86_64-unknown-openbsd6.8] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SanDisk based SSDs
Device Model: SanDisk SDSSDP128G
Serial Number: --
LU WWN Device Id: 5 001b44 ...
Firmware Version: 2.0.0
User Capacity: 128,035,676,160 bytes [128 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 1.8 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sat Mar 20 12:46:38 2021 EET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 120) seconds.
Offline data collection
capabilities: (0x51) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 24) minutes.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
5 Reallocated_Sector_Ct 0x0002 100 100 000 Old_age Always - 0
9 Power_On_Hours 0x0002 100 100 000 Old_age Always - 1340
12 Power_Cycle_Count 0x0002 100 100 000 Old_age Always - 2768
171 Program_Fail_Count 0x0002 100 100 000 Old_age Always - 0
172 Erase_Fail_Count 0x0002 100 100 000 Old_age Always - 0
173 Avg_Write/Erase_Count 0x0002 100 100 000 Old_age Always - 255
174 Unexpect_Power_Loss_Ct 0x0002 100 100 000 Old_age Always - 252
187 Reported_Uncorrect 0x0002 100 100 000 Old_age Always - 0
230 Perc_Write/Erase_Count 0x0002 100 100 000 Old_age Always - 850
232 Perc_Avail_Resrvd_Space 0x0003 100 100 005 Pre-fail Always - 0
234 Perc_Write/Erase_Ct_BC 0x0002 100 100 000 Old_age Always - 1183
241 Total_LBAs_Written 0x0002 100 100 000 Old_age Always - 25052213771
242 Total_LBAs_Read 0x0002 100 100 000 Old_age Always - 46610508438
SMART Error Log Version: 1
No Errors Logged
Warning! SMART Self-Test Log Structure error: invalid SMART checksum.
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 707 -
# 2 Short offline Aborted by host 00% 696 -
# 3 Short offline Completed without error 00% 683 -
# 4 Short offline Completed without error 00% 607 -
# 5 Short offline Completed without error 00% 561 -
# 6 Short offline Completed without error 00% 468 -
# 7 Short offline Completed without error 00% 372 -
# 8 Short offline Completed without error 00% 347 -
# 9 Short offline Completed without error 00% 331 -
#10 Short offline Completed without error 00% 249 -
#11 Short offline Aborted by host 60% 149 -
#12 Short offline Completed without error 00% 138 -
#13 Short offline Completed without error 00% 63 -
#14 Short offline Aborted by host 10% 41 -
#15 Short offline Completed without error 00% 31 -
#16 Short offline Completed without error 00% 6 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
/dev/sd1c
smartctl 7.1 2019-12-30 r5022 [x86_64-unknown-openbsd6.8] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Vendor: OPENBSD
Product: SR CRYPTO
Revision: 006
User Capacity: 119,446,708,224 bytes [119 GB]
Logical block size: 512 bytes
>> Terminate command early due to bad response to IEC mode page
A mandatory SMART command failed: exiting. To continue, add one or more '-T permissive' options.