/dev/ada0
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE amd64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Constellation ES (SATA)
Device Model: ST3500514NS
Serial Number: --
LU WWN Device Id: 5 000c50 ...
Firmware Version: SN11
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 7200 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Mon May 25 14:02:01 2020 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 609) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 87) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x10bd) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 082 063 044 - 192937428
3 Spin_Up_Time PO---- 100 100 000 - 0
4 Start_Stop_Count -O--CK 100 100 020 - 72
5 Reallocated_Sector_Ct PO--CK 098 098 036 - 103
7 Seek_Error_Rate POSR-- 089 060 030 - 886873865
9 Power_On_Hours -O--CK 095 011 000 - 4938
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 100 100 020 - 94
184 End-to-End_Error -O--CK 100 100 099 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
188 Command_Timeout -O--CK 100 091 000 - 120
189 High_Fly_Writes -O-RCK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 074 052 045 - 26 (Min/Max 24/40)
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
192 Power-Off_Retract_Count -O--CK 100 100 000 - 50
193 Load_Cycle_Count -O--CK 100 100 000 - 94
194 Temperature_Celsius -O---K 026 048 000 - 26 (0 12 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 025 017 000 - 192937428
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x12 GPL,SL R/O 1 SATA NCQ Non-Data log
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL VS 2248 Device vendor specific log
0xa8 GPL,SL VS 129 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xb0 GPL VS 2928 Device vendor specific log
0xb6 GPL VS 1918 Device vendor specific log
0xbd GPL VS 252 Device vendor specific log
0xbe-0xbf GPL VS 65535 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 522 (0x020a)
Device State: Active (0)
Current Temperature: 26 Celsius
Power Cycle Min/Max Temperature: 24/40 Celsius
Lifetime Min/Max Temperature: 12/48 Celsius
Under/Over Temperature Limit Count: 0/110489
SCT Temperature History Version: 2
Temperature Sampling Period: 3 minutes
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/ 0 Celsius
Min/Max Temperature Limit: 0/ 0 Celsius
Temperature History Size (Index): 128 (64)
Index Estimated Time Temperature Celsius
65 2020-05-24 16:50 26 *******
... ..( 7 skipped). .. *******
73 2020-05-24 18:10 26 *******
74 2020-05-24 18:20 27 ********
75 2020-05-24 18:30 26 *******
... ..( 24 skipped). .. *******
100 2020-05-24 22:40 26 *******
101 2020-05-24 22:50 27 ********
102 2020-05-24 23:00 26 *******
103 2020-05-24 23:10 26 *******
104 2020-05-24 23:20 27 ********
105 2020-05-24 23:30 27 ********
106 2020-05-24 23:40 26 *******
... ..( 21 skipped). .. *******
0 2020-05-25 03:20 26 *******
1 2020-05-25 03:30 27 ********
... ..( 26 skipped). .. ********
28 2020-05-25 08:00 27 ********
29 2020-05-25 08:10 26 *******
30 2020-05-25 08:20 27 ********
... ..( 3 skipped). .. ********
34 2020-05-25 09:00 27 ********
35 2020-05-25 09:10 26 *******
36 2020-05-25 09:20 27 ********
... ..( 2 skipped). .. ********
39 2020-05-25 09:50 27 ********
40 2020-05-25 10:00 26 *******
41 2020-05-25 10:10 27 ********
... ..( 3 skipped). .. ********
45 2020-05-25 10:50 27 ********
46 2020-05-25 11:00 26 *******
47 2020-05-25 11:10 27 ********
48 2020-05-25 11:20 26 *******
... ..( 9 skipped). .. *******
58 2020-05-25 13:00 26 *******
59 2020-05-25 13:10 27 ********
... ..( 4 skipped). .. ********
64 2020-05-25 14:00 27 ********
SCT Error Recovery Control:
Read: 100 (10.0 seconds)
Write: 100 (10.0 seconds)
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 55 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
/dev/ada1
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE amd64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda ES
Device Model: ST3500630NS
Serial Number: --
Firmware Version: 3.AEG
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Mon May 25 14:02:01 2020 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Unexpected SCT status 0xffff (action_code=4, function_code=2)
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 163) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 114 092 006 - 71582601
3 Spin_Up_Time PO---- 096 093 000 - 0
4 Start_Stop_Count -O--CK 100 100 020 - 166
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
7 Seek_Error_Rate POSR-- 088 060 030 - 700759197
9 Power_On_Hours -O--CK 001 001 000 - 96136
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 100 100 020 - 204
187 Reported_Uncorrect -O--CK 100 100 000 - 0
189 High_Fly_Writes -O-RCK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 066 028 045 Past 34 (Min/Max 31/46 #11235)
194 Temperature_Celsius -O---K 034 072 000 - 34 (0 12 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 057 051 000 - 126809258
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 5 Comprehensive SMART error log
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 1 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x10 GPL,SL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x20 GPL,SL R/O 1 Streaming performance log [OBS-8]
0x21 GPL,SL R/O 1 Write stream error log
0x22 GPL,SL R/O 1 Read stream error log
0x23 GPL,SL R/O 1 Delayed sector log [OBS-8]
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL,SL VS 1 Device vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL,SL VS 101 Device vendor specific log
0xa8 GPL,SL VS 20 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
0xff GPL - 23040 Reserved
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 521 (0x0209)
Device State: Active (0)
Current Temperature: 34 Celsius
Power Cycle Min/Max Temperature: --/46 Celsius
Lifetime Min/Max Temperature: --/72 Celsius
Another SCT command is executing, abort Read Data Table
(SCT ext_status_code 0xffff, action_code=4, function_code=2)
Read SCT Temperature History failed
Another SCT command is executing, abort Error Recovery Control
(SCT ext_status_code 0xffff, action_code=4, function_code=2)
SCT (Get) Error Recovery Control command failed
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 77 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
/dev/da0
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE amd64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Vendor: SEAGATE
Product: ST3300657SS
Revision: 0006
Compliance: SPC-3
User Capacity: 300,000,000,000 bytes [300 GB]
Logical block size: 512 bytes
Rotation Rate: 15015 rpm
Logical Unit id: 0x5000c50028a65153
Serial number: --
Device type: disk
Transport protocol: SAS (SPL-3)
Local Time is: Mon May 25 14:02:01 2020 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
Temperature Warning: Enabled
Read Cache is: Enabled
Writeback Cache is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART Health Status: OK
Current Drive Temperature: 0 C
Drive Trip Temperature: 0 C
Elements in grown defect list: 3
Error Counter logging not supported
Device does not support Self Test logging
Device does not support Background scan results logging
/dev/da1
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE amd64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Vendor: SEAGATE
Product: ST3300657SS
Revision: 0006
Compliance: SPC-3
User Capacity: 300,000,000,000 bytes [300 GB]
Logical block size: 512 bytes
Rotation Rate: 15015 rpm
Logical Unit id: 0x5000c50028a6540f
Serial number: --
Device type: disk
Transport protocol: SAS (SPL-3)
Local Time is: Mon May 25 14:02:01 2020 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
Temperature Warning: Enabled
Read Cache is: Enabled
Writeback Cache is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART Health Status: OK
Current Drive Temperature: 0 C
Drive Trip Temperature: 0 C
Elements in grown defect list: 2
Error Counter logging not supported
Device does not support Self Test logging
Device does not support Background scan results logging