Probe #89a5ee25f9 of Lenovo ThinkPad X270 W10DG ...
Log: smartctl
/dev/nvd0
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: SAMSUNG MZVLW256HEHP-000L7
Serial Number: --
Firmware Version: 5L7QCXB7
PCI Vendor/Subsystem ID: 0x144d
IEEE OUI Identifier: 0x002538
Total NVM Capacity: 256,060,514,304 [256 GB]
Unallocated NVM Capacity: 0
Controller ID: 2
NVMe Version: 1.2
Number of Namespaces: 1
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
Namespace 1 Utilization: 75,463,614,464 [75.4 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 002538 ...
Local Time is: Tue Mar 14 15:57:59 2023 UTC
Firmware Updates (0x16): 3 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg
Warning Comp. Temp. Threshold: 69 Celsius
Critical Comp. Temp. Threshold: 72 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 7.60W - - 0 0 0 0 0 0
1 + 6.00W - - 1 1 1 1 0 0
2 + 5.10W - - 2 2 2 2 0 0
3 - 0.0400W - - 3 3 3 3 210 1500
4 - 0.0050W - - 4 4 4 4 2200 6000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 27 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 1%
Data Units Read: 17,520,019 [8.97 TB]
Data Units Written: 10,445,971 [5.34 TB]
Host Read Commands: 308,662,880
Host Write Commands: 269,394,311
Controller Busy Time: 768
Power Cycles: 1,037
Power On Hours: 1,554
Unsafe Shutdowns: 237
Media and Data Integrity Errors: 0
Error Information Log Entries: 3,071
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 27 Celsius
Temperature Sensor 2: 28 Celsius
Error Information (NVMe Log 0x01, 16 of 64 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS
0 3071 0 0x4016 0x4004 - 0 0 -
1 3070 0 0x1010 0x4004 - 0 0 -
2 3069 0 0x001e 0x4016 0x004 0 1 -
3 3068 0 0x1004 0x4004 - 0 0 -
4 3067 0 0x002e 0x4016 0x004 0 1 -
5 3066 0 0x400a 0x4004 - 0 0 -
6 3065 0 0x002e 0x4016 0x004 0 1 -
7 3064 0 0x1004 0x4004 - 0 0 -
8 3063 0 0x700b 0x4004 - 0 0 -
9 3062 0 0x4016 0x4004 - 0 0 -
10 3061 0 0x1004 0x4004 - 0 0 -
11 3060 0 0x002e 0x4016 0x004 0 1 -
12 3059 0 0x300a 0x4004 - 0 0 -
13 3058 0 0x100b 0x4004 - 0 0 -
14 3057 0 0xe00a 0x4004 - 0 0 -
15 3056 0 0x8001 0x4004 - 0 0 -
... (48 entries not read)