Probe #753b30d88b of Lenovo NO DPK Desktop Computer (ThinkCentre M72e 3598CP8)

Log: smartctl

/dev/sd0 smartctl 7.3 2022-02-28 r5338 [NetBSD 9.3 amd64] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Vendor: SAMSUNG Product: HD501LJ User Capacity: 500,107,862,016 bytes [500 GB] Logical block size: 512 bytes Device type: disk Local Time is: Fri Oct 27 23:26:19 2023 JST SMART support is: Unavailable - device lacks SMART capability. === START OF READ SMART DATA SECTION === Current Drive Temperature: 0 C Drive Trip Temperature: 0 C Error Counter logging not supported Device does not support Self Test logging /dev/wd0 smartctl 7.3 2022-02-28 r5338 [NetBSD 9.3 amd64] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: HGST Travelstar 5K1000 Device Model: HGST HTS541010A9E680 Serial Number: -- LU WWN Device Id: 5 000cca ... Firmware Version: JA0OA560 User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 5400 rpm Form Factor: 2.5 inches Device is: In smartctl database 7.3/5319 ATA Version is: ATA8-ACS T13/1699-D revision 6 SATA Version is: SATA 2.6, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Fri Oct 27 23:26:19 2023 JST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 45) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 258) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 100 100 062 Pre-fail Always - 0 2 Throughput_Performance 0x0005 100 100 040 Pre-fail Offline - 0 3 Spin_Up_Time 0x0007 253 253 033 Pre-fail Always - 0 4 Start_Stop_Count 0x0012 001 001 000 Old_age Always - 269256 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 0 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0 8 Seek_Time_Performance 0x0005 100 100 040 Pre-fail Offline - 0 9 Power_On_Hours 0x0012 076 076 000 Old_age Always - 10762 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 321 191 G-Sense_Error_Rate 0x000a 100 100 000 Old_age Always - 0 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 48 193 Load_Cycle_Count 0x0012 001 001 000 Old_age Always - 1469955 194 Temperature_Celsius 0x0002 214 214 000 Old_age Always - 28 (Min/Max 13/42) 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0 223 Load_Retry_Count 0x000a 100 100 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.


Hardware for Linux and BSD

GitHub