Probe #67a336fac6 of Alienware M18xR1

Log: smartctl

/dev/ada0 smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p2 amd64] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Samsung based SSDs Device Model: SAMSUNG SSD PM810 2.5" 7mm 256GB Serial Number: -- LU WWN Device Id: 5 0000f0 ... Firmware Version: AXM08D1Q User Capacity: 256,060,514,304 bytes [256 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device TRIM Command: Available Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS, ATA/ATAPI-7 T13/1532D revision 1 SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s) Local Time is: Mon Feb 8 17:21:45 2021 GMT SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Disabled APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Unavailable === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 1680) seconds. Offline data collection capabilities: (0x53) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 28) minutes. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 5 Reallocated_Sector_Ct PO--CK 099 099 --- - 13 9 Power_On_Hours -O--CK 098 098 --- - 8697 12 Power_Cycle_Count -O--CK 097 097 --- - 2573 175 Program_Fail_Count_Chip -O--CK 099 099 --- - 12 176 Erase_Fail_Count_Chip -O--CK 100 100 --- - 0 177 Wear_Leveling_Count PO--C- 098 098 --- - 58 178 Used_Rsvd_Blk_Cnt_Chip PO--C- 077 077 --- - 902 179 Used_Rsvd_Blk_Cnt_Tot PO--C- 079 079 --- - 1670 180 Unused_Rsvd_Blk_Cnt_Tot PO--C- 079 079 --- - 6394 181 Program_Fail_Cnt_Total -O--CK 099 099 --- - 13 182 Erase_Fail_Count_Total -O--CK 100 100 --- - 0 183 Runtime_Bad_Block PO--C- 099 099 --- - 13 187 Uncorrectable_Error_Cnt -O--CK 099 099 --- - 11 195 ECC_Error_Rate -O-RC- 199 199 --- - 11 198 Offline_Uncorrectable ----CK 100 100 --- - 0 199 CRC_Error_Count -OSRCK 253 253 --- - 1 232 Available_Reservd_Space PO--C- 077 077 --- - 3130 241 Total_LBAs_Written -O--CK 003 003 --- - 4187556915 242 Total_LBAs_Read -O--CK 078 078 --- - 944270717 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 0 Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 GPL,SL R/O 1 Summary SMART error log 0x02 GPL,SL R/O 1 Comprehensive SMART error log 0x03 GPL,SL R/O 1 Ext. Comprehensive SMART error log 0x06 GPL,SL R/O 1 SMART self-test log 0x07 GPL,SL R/O 1 Extended self-test log 0x09 GPL,SL R/W 1 Selective self-test log 0x10 GPL,SL R/O 1 NCQ Command Error log 0x11 GPL,SL R/O 1 SATA Phy Event Counters log 0x80-0x9f GPL,SL R/W 1 Host vendor specific log Warning! SMART Extended Comprehensive Error Log Structure error: invalid SMART checksum. SMART Extended Comprehensive Error Log Version: 1 (1 sectors) Device Error Count: 8 (device log contains only the most recent 4 errors) CR = Command Register FEATR = Features Register COUNT = Count (was: Sector Count) Register LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8 LH = LBA High (was: Cylinder High) Register ] LBA LM = LBA Mid (was: Cylinder Low) Register ] Register LL = LBA Low (was: Sector Number) Register ] DV = Device (was: Device/Head) Register DC = Device Control Register ER = Error register ST = Status register Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 8 [3] occurred at disk power-on lifetime: 8481 hours (353 days + 9 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 00 00 00 00 08 56 81 40 00 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- ea 00 00 00 00 00 00 00 00 00 00 00 00 00:27:40.000 FLUSH CACHE EXT 61 00 10 00 f8 00 00 00 66 da e0 40 00 00:27:40.000 WRITE FPDMA QUEUED Error 7 [2] occurred at disk power-on lifetime: 8481 hours (353 days + 9 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 00 00 00 00 66 db 1f 40 00 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- ea 00 00 00 00 00 00 00 00 00 00 00 00 00:27:40.000 FLUSH CACHE EXT 61 00 08 00 d8 00 00 00 66 da 60 40 00 00:27:40.000 WRITE FPDMA QUEUED 61 00 18 00 d0 00 00 05 95 cb b0 40 00 00:27:40.000 WRITE FPDMA QUEUED 61 00 08 00 c8 00 00 06 82 2d 88 40 00 00:27:40.000 WRITE FPDMA QUEUED 61 00 08 00 b0 00 00 06 84 8c 58 40 00 00:27:40.000 WRITE FPDMA QUEUED Error 6 [1] occurred at disk power-on lifetime: 8481 hours (353 days + 9 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 01 00 00 00 08 56 80 40 00 Error: WP at LBA = 0x00085680 = 546432 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 61 00 08 00 50 00 00 00 66 da 58 40 00 00:27:37.000 WRITE FPDMA QUEUED 61 00 08 00 48 00 00 06 86 53 98 40 00 00:27:37.000 WRITE FPDMA QUEUED 61 00 28 00 40 00 00 08 98 32 e0 40 00 00:27:37.000 WRITE FPDMA QUEUED 61 00 10 00 38 00 00 07 76 27 a8 40 00 00:27:37.000 WRITE FPDMA QUEUED 61 00 08 00 28 00 00 0a 13 74 d8 40 00 00:27:37.000 WRITE FPDMA QUEUED Error 5 [0] occurred at disk power-on lifetime: 8481 hours (353 days + 9 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 01 00 00 00 08 56 80 40 00 Error: WP at LBA = 0x00085680 = 546432 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 61 00 08 00 c8 00 00 00 66 da c0 40 00 00:27:34.000 WRITE FPDMA QUEUED 2f 00 00 00 01 00 00 00 00 00 04 00 00 00:27:34.000 READ LOG EXT ec 00 00 00 01 00 00 00 00 00 00 00 00 00:27:34.000 IDENTIFY DEVICE ef 00 10 00 03 00 00 00 00 00 00 00 00 00:27:34.000 SET FEATURES [Enable SATA feature] ef 00 10 00 02 00 00 00 00 00 00 00 00 00:27:34.000 SET FEATURES [Enable SATA feature] Warning! SMART Extended Self-test Log Structure error: invalid SMART checksum. SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 8672 - # 2 Short offline Completed: read failure 90% 8481 546304 # 3 Short offline Completed: read failure 90% 8481 546304 # 4 Short offline Completed without error 00% 3846 - # 5 Short offline Completed without error 00% 3083 - # 6 Short offline Completed without error 00% 3003 - # 7 Short offline Completed without error 00% 2992 - # 8 Short offline Completed without error 00% 2992 - # 9 Short offline Completed without error 00% 2936 - #10 Short offline Completed without error 00% 2935 - #11 Short offline Completed without error 00% 2618 - #12 Short offline Completed without error 00% 2424 - #13 Short offline Completed without error 00% 1921 - #14 Short offline Completed without error 00% 1614 - #15 Short offline Completed without error 00% 1611 - #16 Short offline Completed without error 00% 1562 - #17 Short offline Completed without error 00% 963 - #18 Short offline Completed without error 00% 921 - #19 Short offline Completed without error 00% 847 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Commands not supported Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 12 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 12 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC


Hardware for Linux and BSD

GitHub