Probe #627bdfafb7 of ASUSTek P8Z77-M Desktop Computer

Log: smartctl

/dev/ada0 smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Marvell based SanDisk SSDs Device Model: SanDisk SDSSDH2256G Serial Number: -- LU WWN Device Id: 5 001b44 ... Firmware Version: X211200 User Capacity: 256,060,514,304 bytes [256 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: Unknown (0x000a) TRIM Command: Available, deterministic, zeroed Device is: In smartctl database 7.3/5319 ATA Version is: ATA8-ACS T13/1699-D revision 6 SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Mon Feb 6 12:13:34 2023 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM level is: 128 (minimum power consumption without standby) Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Unavailable === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x11) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 10) minutes. SMART Attributes Data Structure revision number: 4 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate -OSR-- 100 100 --- - 0 5 Reallocated_Sector_Ct -O--CK 100 100 --- - 0 9 Power_On_Hours -O--CK 253 100 --- - 10898 12 Power_Cycle_Count -O--CK 100 100 --- - 4119 167 Min_Bad_Block/Die -O--CK 100 100 --- - 34 168 Maximum_Erase_Cycle -O--CK 100 100 --- - 227 169 Total_Bad_Block -O--CK 100 100 --- - 352 171 Program_Fail_Count -O--CK 100 100 --- - 0 172 Erase_Fail_Count -O--CK 100 100 --- - 0 173 Avg_Write/Erase_Count -O--CK 100 100 --- - 109 174 Unexpect_Power_Loss_Ct -O--CK 100 100 --- - 130 184 End-to-End_Error -O--CK 100 100 --- - 0 194 Temperature_Celsius -O---K 068 147 --- - 32 (0 147 0 2 0) 212 SATA_PHY_Error -O--CK 100 100 --- - 0 230 Perc_Write/Erase_Count -O--CK 100 100 --- - 0 0 831 232 Perc_Avail_Resrvd_Space PO--CK 100 100 004 - 100 233 Total_NAND_Writes_GiB -O--CK 100 100 --- - 831 241 Total_Writes_GiB ----CK 253 253 --- - 22697170933 242 Total_Reads_GiB ----CK 253 253 --- - 22141866564 243 Unknown_Marvell_Attr -O--CK 100 100 --- - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 2 Comprehensive SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x04 GPL,SL R/O 8 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log SMART Extended Comprehensive Error Log Version: 1 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) No self-tests have been logged. [To run self-tests, use: smartctl -t] Selective Self-tests/Logging not supported SCT Commands not supported Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x07 ===== = = === == Solid State Device Statistics (rev 1) == 0x07 0x008 1 3 --- Percentage Used Endurance Indicator |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 4 0 Command failed due to ICRC error 0x0002 4 0 R_ERR response for data FIS 0x0005 4 0 R_ERR response for non-data FIS 0x000a 4 10 Device-to-host register FISes sent due to a COMRESET /dev/ada1 smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Samsung based SSDs Device Model: Samsung SSD 860 EVO 1TB Serial Number: -- LU WWN Device Id: 5 002538 ... Firmware Version: RVT03B6Q User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches TRIM Command: Available, deterministic, zeroed Device is: In smartctl database 7.3/5319 ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5 SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Mon Feb 6 12:13:34 2023 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x53) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 85) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0 9 Power_On_Hours -O--CK 098 098 000 - 5239 12 Power_Cycle_Count -O--CK 098 098 000 - 1266 177 Wear_Leveling_Count PO--C- 099 099 000 - 4 179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0 181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0 182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0 183 Runtime_Bad_Block PO--C- 100 100 010 - 0 187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0 190 Airflow_Temperature_Cel -O--CK 071 042 000 - 29 195 ECC_Error_Rate -O-RC- 200 200 000 - 0 199 CRC_Error_Count -OSRCK 100 100 000 - 0 235 POR_Recovery_Count -O--C- 099 099 000 - 16 241 Total_LBAs_Written -O--CK 099 099 000 - 6753103260 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 1 Comprehensive SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x04 GPL,SL R/O 8 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x13 GPL R/O 1 SATA NCQ Send and Receive log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa1 SL VS 16 Device vendor specific log 0xa5 SL VS 16 Device vendor specific log 0xce SL VS 16 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 256 (0x0100) Device State: Active (0) Current Temperature: 29 Celsius Power Cycle Min/Max Temperature: 29/40 Celsius Lifetime Min/Max Temperature: 19/58 Celsius Specified Max Operating Temperature: 70 Celsius Under/Over Temperature Limit Count: 0/0 SMART Status: 0xc24f (PASSED) SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 10 minutes Min/Max recommended Temperature: 0/70 Celsius Min/Max Temperature Limit: 0/70 Celsius Temperature History Size (Index): 128 (89) Index Estimated Time Temperature Celsius 90 2023-02-05 15:00 32 ************* 91 2023-02-05 15:10 31 ************ 92 2023-02-05 15:20 31 ************ 93 2023-02-05 15:30 ? - 94 2023-02-05 15:40 21 ** 95 2023-02-05 15:50 23 **** 96 2023-02-05 16:00 25 ****** 97 2023-02-05 16:10 26 ******* 98 2023-02-05 16:20 28 ********* 99 2023-02-05 16:30 29 ********** 100 2023-02-05 16:40 30 *********** ... ..( 5 skipped). .. *********** 106 2023-02-05 17:40 30 *********** 107 2023-02-05 17:50 29 ********** ... ..( 20 skipped). .. ********** 0 2023-02-05 21:20 29 ********** 1 2023-02-05 21:30 30 *********** 2 2023-02-05 21:40 31 ************ 3 2023-02-05 21:50 32 ************* 4 2023-02-05 22:00 32 ************* 5 2023-02-05 22:10 32 ************* 6 2023-02-05 22:20 31 ************ 7 2023-02-05 22:30 31 ************ 8 2023-02-05 22:40 30 *********** 9 2023-02-05 22:50 30 *********** 10 2023-02-05 23:00 30 *********** 11 2023-02-05 23:10 29 ********** ... ..( 11 skipped). .. ********** 23 2023-02-06 01:10 29 ********** 24 2023-02-06 01:20 30 *********** ... ..( 2 skipped). .. *********** 27 2023-02-06 01:50 30 *********** 28 2023-02-06 02:00 31 ************ ... ..( 3 skipped). .. ************ 32 2023-02-06 02:40 31 ************ 33 2023-02-06 02:50 ? - 34 2023-02-06 03:00 22 *** 35 2023-02-06 03:10 24 ***** 36 2023-02-06 03:20 25 ****** 37 2023-02-06 03:30 27 ******** 38 2023-02-06 03:40 27 ******** 39 2023-02-06 03:50 29 ********** 40 2023-02-06 04:00 30 *********** 41 2023-02-06 04:10 29 ********** ... ..( 8 skipped). .. ********** 50 2023-02-06 05:40 29 ********** 51 2023-02-06 05:50 28 ********* 52 2023-02-06 06:00 29 ********** ... ..( 2 skipped). .. ********** 55 2023-02-06 06:30 29 ********** 56 2023-02-06 06:40 30 *********** 57 2023-02-06 06:50 ? - 58 2023-02-06 07:00 22 *** 59 2023-02-06 07:10 24 ***** 60 2023-02-06 07:20 25 ****** 61 2023-02-06 07:30 27 ******** ... ..( 2 skipped). .. ******** 64 2023-02-06 08:00 27 ******** 65 2023-02-06 08:10 28 ********* ... ..( 3 skipped). .. ********* 69 2023-02-06 08:50 28 ********* 70 2023-02-06 09:00 30 *********** 71 2023-02-06 09:10 28 ********* ... ..( 9 skipped). .. ********* 81 2023-02-06 10:50 28 ********* 82 2023-02-06 11:00 27 ******** 83 2023-02-06 11:10 27 ******** 84 2023-02-06 11:20 28 ********* 85 2023-02-06 11:30 28 ********* 86 2023-02-06 11:40 ? - 87 2023-02-06 11:50 29 ********** 88 2023-02-06 12:00 29 ********** 89 2023-02-06 12:10 29 ********** SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 1) == 0x01 0x008 4 1266 --- Lifetime Power-On Resets 0x01 0x010 4 5239 --- Power-on Hours 0x01 0x018 6 6753103260 --- Logical Sectors Written 0x01 0x020 6 137340190 --- Number of Write Commands 0x01 0x028 6 6838864993 --- Logical Sectors Read 0x01 0x030 6 102574811 --- Number of Read Commands 0x01 0x038 6 2961000 --- Date and Time TimeStamp 0x04 ===== = = === == General Errors Statistics (rev 1) == 0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors 0x04 0x010 4 1 --- Resets Between Cmd Acceptance and Completion 0x05 ===== = = === == Temperature Statistics (rev 1) == 0x05 0x008 1 29 --- Current Temperature 0x05 0x020 1 58 --- Highest Temperature 0x05 0x028 1 19 --- Lowest Temperature 0x05 0x058 1 70 --- Specified Maximum Operating Temperature 0x06 ===== = = === == Transport Statistics (rev 1) == 0x06 0x008 4 6274 --- Number of Hardware Resets 0x06 0x010 4 0 --- Number of ASR Events 0x06 0x018 4 0 --- Number of Interface CRC Errors 0x07 ===== = = === == Solid State Device Statistics (rev 1) == 0x07 0x008 1 0 N-- Percentage Used Endurance Indicator |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 9 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 9 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC /dev/ada2 smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Caviar Black Device Model: WDC WD2002FAEX-007BA0 Serial Number: -- LU WWN Device Id: 5 0014ee ... Firmware Version: 05.01D05 User Capacity: 2,000,398,934,016 bytes [2.00 TB] Sector Size: 512 bytes logical/physical Device is: In smartctl database 7.3/5319 ATA Version is: ATA8-ACS (minor revision not indicated) SATA Version is: SATA 2.6, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Mon Feb 6 12:13:35 2023 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (30180) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 307) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x3037) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 5 3 Spin_Up_Time POS--K 253 253 021 - 8375 4 Start_Stop_Count -O--CK 097 097 000 - 3127 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 100 253 000 - 0 9 Power_On_Hours -O--CK 089 089 000 - 8280 10 Spin_Retry_Count -O--CK 100 100 000 - 0 11 Calibration_Retry_Count -O--CK 100 100 000 - 0 12 Power_Cycle_Count -O--CK 098 098 000 - 2903 192 Power-Off_Retract_Count -O--CK 200 200 000 - 62 193 Load_Cycle_Count -O--CK 199 199 000 - 3064 194 Temperature_Celsius -O---K 100 087 000 - 52 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 200 200 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 6 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log 0xa8-0xb5 GPL,SL VS 1 Device vendor specific log 0xb6 GPL VS 1 Device vendor specific log 0xb7 GPL,SL VS 1 Device vendor specific log 0xbd GPL,SL VS 1 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xc1 GPL VS 24 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (6 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 258 (0x0102) Device State: Active (0) Current Temperature: 52 Celsius Power Cycle Min/Max Temperature: 52/52 Celsius Lifetime Min/Max Temperature: 0/65 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -41/85 Celsius Temperature History Size (Index): 478 (448) Index Estimated Time Temperature Celsius 449 2023-02-06 04:16 52 ********************************* ... ..( 19 skipped). .. ********************************* 469 2023-02-06 04:36 52 ********************************* 470 2023-02-06 04:37 ? - 471 2023-02-06 04:38 19 - 472 2023-02-06 04:39 19 - 473 2023-02-06 04:40 19 - 474 2023-02-06 04:41 21 ** 475 2023-02-06 04:42 21 ** 476 2023-02-06 04:43 22 *** 477 2023-02-06 04:44 24 ***** 0 2023-02-06 04:45 25 ****** 1 2023-02-06 04:46 25 ****** 2 2023-02-06 04:47 26 ******* 3 2023-02-06 04:48 26 ******* 4 2023-02-06 04:49 27 ******** 5 2023-02-06 04:50 28 ********* 6 2023-02-06 04:51 29 ********** 7 2023-02-06 04:52 29 ********** 8 2023-02-06 04:53 30 *********** 9 2023-02-06 04:54 31 ************ 10 2023-02-06 04:55 32 ************* 11 2023-02-06 04:56 32 ************* 12 2023-02-06 04:57 32 ************* 13 2023-02-06 04:58 33 ************** 14 2023-02-06 04:59 34 *************** 15 2023-02-06 05:00 34 *************** 16 2023-02-06 05:01 35 **************** 17 2023-02-06 05:02 35 **************** 18 2023-02-06 05:03 35 **************** 19 2023-02-06 05:04 36 ***************** 20 2023-02-06 05:05 36 ***************** 21 2023-02-06 05:06 37 ****************** 22 2023-02-06 05:07 38 ******************* 23 2023-02-06 05:08 38 ******************* 24 2023-02-06 05:09 39 ******************** 25 2023-02-06 05:10 39 ******************** 26 2023-02-06 05:11 40 ********************* ... ..( 3 skipped). .. ********************* 30 2023-02-06 05:15 40 ********************* 31 2023-02-06 05:16 41 ********************** 32 2023-02-06 05:17 41 ********************** 33 2023-02-06 05:18 41 ********************** 34 2023-02-06 05:19 42 *********************** 35 2023-02-06 05:20 42 *********************** 36 2023-02-06 05:21 43 ************************ ... ..( 2 skipped). .. ************************ 39 2023-02-06 05:24 43 ************************ 40 2023-02-06 05:25 44 ************************* ... ..( 2 skipped). .. ************************* 43 2023-02-06 05:28 44 ************************* 44 2023-02-06 05:29 45 ************************** ... ..( 3 skipped). .. ************************** 48 2023-02-06 05:33 45 ************************** 49 2023-02-06 05:34 46 *************************** ... ..( 4 skipped). .. *************************** 54 2023-02-06 05:39 46 *************************** 55 2023-02-06 05:40 47 **************************** ... ..( 5 skipped). .. **************************** 61 2023-02-06 05:46 47 **************************** 62 2023-02-06 05:47 48 ***************************** ... ..( 9 skipped). .. ***************************** 72 2023-02-06 05:57 48 ***************************** 73 2023-02-06 05:58 49 ****************************** ... ..( 13 skipped). .. ****************************** 87 2023-02-06 06:12 49 ****************************** 88 2023-02-06 06:13 50 ******************************* ... ..( 30 skipped). .. ******************************* 119 2023-02-06 06:44 50 ******************************* 120 2023-02-06 06:45 51 ******************************** ... ..(160 skipped). .. ******************************** 281 2023-02-06 09:26 51 ******************************** 282 2023-02-06 09:27 ? - 283 2023-02-06 09:28 52 ********************************* ... ..( 36 skipped). .. ********************************* 320 2023-02-06 10:05 52 ********************************* 321 2023-02-06 10:06 50 ******************************* ... ..( 13 skipped). .. ******************************* 335 2023-02-06 10:20 50 ******************************* 336 2023-02-06 10:21 51 ******************************** ... ..(101 skipped). .. ******************************** 438 2023-02-06 12:03 51 ******************************** 439 2023-02-06 12:04 52 ********************************* ... ..( 8 skipped). .. ********************************* 448 2023-02-06 12:13 52 ********************************* SCT Error Recovery Control command not supported Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x000a 2 7 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x8000 4 2356 Vendor specific /dev/da0 smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: TS240GESD240C Serial Number: -- LU WWN Device Id: 0 000000 ... Firmware Version: S1031B0 User Capacity: 240,057,409,536 bytes [240 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: M.2 TRIM Command: Available, deterministic Device is: Not in smartctl database 7.3/5319 ATA Version is: ACS-2 T13/2015-D revision 3 SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Mon Feb 6 12:13:35 2023 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM level is: 128 (minimum power consumption without standby) Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Unavailable === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 120) seconds. Offline data collection capabilities: (0x11) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0002) Does not save SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 10) minutes. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate -O--CK 100 100 050 - 0 5 Reallocated_Sector_Ct -O--CK 100 100 050 - 0 9 Power_On_Hours -O--CK 100 100 050 - 168 12 Power_Cycle_Count -O--CK 100 100 050 - 84 160 Unknown_Attribute -O--CK 100 100 050 - 0 161 Unknown_Attribute PO--CK 100 100 050 - 100 163 Unknown_Attribute -O--CK 100 100 050 - 154 164 Unknown_Attribute -O--CK 100 100 050 - 11151 165 Unknown_Attribute -O--CK 100 100 050 - 9 166 Unknown_Attribute -O--CK 100 100 050 - 1 167 Unknown_Attribute -O--CK 100 100 050 - 3 168 Unknown_Attribute -O--CK 100 100 050 - 1000 169 Unknown_Attribute -O--CK 100 100 050 - 100 175 Program_Fail_Count_Chip -O--CK 100 100 050 - 0 176 Erase_Fail_Count_Chip -O--CK 100 100 050 - 0 177 Wear_Leveling_Count -O--CK 100 100 050 - 0 178 Used_Rsvd_Blk_Cnt_Chip -O--CK 100 100 050 - 0 181 Program_Fail_Cnt_Total -O--CK 100 100 050 - 0 182 Erase_Fail_Count_Total -O--CK 100 100 050 - 0 192 Power-Off_Retract_Count -O--CK 100 100 050 - 84 194 Temperature_Celsius -O---K 100 100 050 - 39 195 Hardware_ECC_Recovered -O--CK 100 100 050 - 0 196 Reallocated_Event_Count -O--CK 100 100 050 - 0 197 Current_Pending_Sector -O--CK 100 100 050 - 0 198 Offline_Uncorrectable -O--CK 100 100 050 - 0 199 UDMA_CRC_Error_Count -O--CK 100 100 050 - 2 232 Available_Reservd_Space -O--CK 100 100 050 - 100 241 Total_LBAs_Written ----CK 100 100 050 - 8510 242 Total_LBAs_Read ----CK 100 100 050 - 374 245 Unknown_Attribute -O--CK 100 100 050 - 7029 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 1 Comprehensive SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x04 GPL,SL R/O 8 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xde GPL VS 8 Device vendor specific log SMART Extended Comprehensive Error Log Version: 1 (1 sectors) Device Error Count: 13 (device log contains only the most recent 4 errors) CR = Command Register FEATR = Features Register COUNT = Count (was: Sector Count) Register LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8 LH = LBA High (was: Cylinder High) Register ] LBA LM = LBA Mid (was: Cylinder Low) Register ] Register LL = LBA Low (was: Sector Number) Register ] DV = Device (was: Device/Head) Register DC = Device Control Register ER = Error register ST = Status register Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 13 [0] log entry is empty Error 12 [3] log entry is empty Error 11 [2] log entry is empty Error 10 [1] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 00 -- 00 00 00 00 00 00 00 00 00 00 00 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- b0 00 d1 01 01 00 00 4f 00 c2 01 00 00 00:00:00.000 SMART READ ATTRIBUTE THRESHOLDS [OBS-4] 2f 00 00 01 01 00 00 00 00 00 03 00 00 00:00:00.000 READ LOG EXT 2f 00 00 01 01 00 00 00 00 00 00 00 00 00:00:00.000 READ LOG EXT b0 00 d5 01 01 00 00 4f 00 c2 00 00 00 00:00:00.000 SMART READ LOG b0 00 da 00 00 00 00 4f 00 c2 00 00 00 00:00:00.000 SMART RETURN STATUS SMART Extended Self-test Log Version: 1 (1 sectors) No self-tests have been logged. [To run self-tests, use: smartctl -t] Selective Self-tests/Logging not supported SCT Commands not supported Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 1) == 0x01 0x008 4 84 --- Lifetime Power-On Resets 0x01 0x010 4 168 --- Power-on Hours 0x01 0x018 6 557754013 --- Logical Sectors Written 0x01 0x020 6 0 --- Number of Write Commands 0x01 0x028 6 24541371 --- Logical Sectors Read 0x01 0x030 6 13077 --- Number of Read Commands 0x07 ===== = = === == Solid State Device Statistics (rev 1) == 0x07 0x008 1 0 --- Percentage Used Endurance Indicator |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 4 0 Command failed due to ICRC error 0x0002 4 0 R_ERR response for data FIS 0x0005 4 0 R_ERR response for non-data FIS 0x000a 4 0 Device-to-host register FISes sent due to a COMRESET


Hardware for Linux and BSD

GitHub