Probe #5e66766fea of HP 1589 Desktop Computer (Z420 Workstation)

Log: smartctl

/dev/ada0 smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p5 amd64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Hitachi Deskstar 7K1000.C Device Model: Hitachi HDS721025CLA382 Serial Number: -- LU WWN Device Id: 5 000cca ... Firmware Version: JP1OA3GH User Capacity: 250,059,350,016 bytes [250 GB] Sector Size: 512 bytes logical/physical Rotation Rate: 7200 rpm Form Factor: 3.5 inches Device is: In smartctl database 7.3/5528 ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 2.6, 3.0 Gb/s Local Time is: Sat Jan 11 13:47:03 2025 EET SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 2381) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 40) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 100 100 016 - 0 2 Throughput_Performance POS--K 136 100 054 - 95 3 Spin_Up_Time PO---K 115 100 024 - 201 (Average 197) 4 Start_Stop_Count -O---K 100 100 000 - 216 5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0 7 Seek_Error_Rate POSR-K 100 100 067 - 0 8 Seek_Time_Performance P-S--K 138 100 020 - 31 9 Power_On_Hours -O--CK 100 100 000 - 1908 10 Spin_Retry_Count PO--CK 100 100 060 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 216 183 Runtime_Bad_Block -O--CK 100 100 000 - 0 184 End-to-End_Error PO--CK 100 100 097 - 0 185 Unknown_Attribute -O--CK 100 100 000 - 65535 187 Reported_Uncorrect -O--CK 100 100 000 - 0 188 Command_Timeout -O--CK 100 096 000 - 5439571 189 High_Fly_Writes -O--CK 100 100 000 - 0 190 Airflow_Temperature_Cel -O---K 073 057 000 - 27 (Min/Max 17/27) 192 Power-Off_Retract_Count -O--CK 100 100 000 - 216 193 Load_Cycle_Count -O--CK 100 100 000 - 216 194 Temperature_Celsius -O---- 222 139 000 - 27 (Min/Max 12/43) 196 Reallocated_Event_Count -O--CK 100 100 000 - 0 197 Current_Pending_Sector -O--CK 100 100 000 - 0 198 Offline_Uncorrectable ----CK 100 100 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x04 GPL R/O 7 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x20 GPL R/O 1 Streaming performance log 0x21 GPL R/O 1 Write stream error log 0x22 GPL R/O 1 Read stream error log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 0 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 0 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 256 (0x0100) Device State: SMART Off-line Data Collection executing in background (4) Current Temperature: 27 Celsius Power Cycle Min/Max Temperature: 17/27 Celsius Lifetime Min/Max Temperature: 12/43 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -40/70 Celsius Temperature History Size (Index): 128 (126) Index Estimated Time Temperature Celsius 127 2025-01-11 11:40 31 ************ ... ..( 4 skipped). .. ************ 4 2025-01-11 11:45 31 ************ 5 2025-01-11 11:46 30 *********** 6 2025-01-11 11:47 31 ************ 7 2025-01-11 11:48 31 ************ 8 2025-01-11 11:49 30 *********** ... ..( 4 skipped). .. *********** 13 2025-01-11 11:54 30 *********** 14 2025-01-11 11:55 31 ************ 15 2025-01-11 11:56 30 *********** ... ..( 8 skipped). .. *********** 24 2025-01-11 12:05 30 *********** 25 2025-01-11 12:06 31 ************ ... ..( 13 skipped). .. ************ 39 2025-01-11 12:20 31 ************ 40 2025-01-11 12:21 30 *********** 41 2025-01-11 12:22 30 *********** 42 2025-01-11 12:23 31 ************ 43 2025-01-11 12:24 31 ************ 44 2025-01-11 12:25 31 ************ 45 2025-01-11 12:26 30 *********** ... ..( 8 skipped). .. *********** 54 2025-01-11 12:35 30 *********** 55 2025-01-11 12:36 31 ************ ... ..( 11 skipped). .. ************ 67 2025-01-11 12:48 31 ************ 68 2025-01-11 12:49 30 *********** 69 2025-01-11 12:50 30 *********** 70 2025-01-11 12:51 31 ************ ... ..( 10 skipped). .. ************ 81 2025-01-11 13:02 31 ************ 82 2025-01-11 13:03 30 *********** ... ..( 6 skipped). .. *********** 89 2025-01-11 13:10 30 *********** 90 2025-01-11 13:11 31 ************ ... ..( 8 skipped). .. ************ 99 2025-01-11 13:20 31 ************ 100 2025-01-11 13:21 30 *********** 101 2025-01-11 13:22 31 ************ ... ..( 4 skipped). .. ************ 106 2025-01-11 13:27 31 ************ 107 2025-01-11 13:28 ? - 108 2025-01-11 13:29 18 - 109 2025-01-11 13:30 19 - 110 2025-01-11 13:31 21 ** 111 2025-01-11 13:32 22 *** 112 2025-01-11 13:33 23 **** 113 2025-01-11 13:34 23 **** 114 2025-01-11 13:35 23 **** 115 2025-01-11 13:36 24 ***** 116 2025-01-11 13:37 24 ***** 117 2025-01-11 13:38 25 ****** 118 2025-01-11 13:39 25 ****** 119 2025-01-11 13:40 25 ****** 120 2025-01-11 13:41 26 ******* 121 2025-01-11 13:42 26 ******* 122 2025-01-11 13:43 26 ******* 123 2025-01-11 13:44 27 ******** ... ..( 2 skipped). .. ******** 126 2025-01-11 13:47 27 ******** SCT Error Recovery Control: Read: 85 (8.5 seconds) Write: 85 (8.5 seconds) Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 1) == 0x01 0x008 4 216 --- Lifetime Power-On Resets 0x01 0x010 4 1908 --- Power-on Hours 0x01 0x018 6 3586773417 --- Logical Sectors Written 0x01 0x020 6 47573446 --- Number of Write Commands 0x01 0x028 6 22904944046 --- Logical Sectors Read 0x01 0x030 6 35425817 --- Number of Read Commands 0x03 ===== = = === == Rotating Media Statistics (rev 1) == 0x03 0x008 4 1907 --- Spindle Motor Power-on Hours 0x03 0x010 4 1907 --- Head Flying Hours 0x03 0x018 4 216 --- Head Load Events 0x03 0x020 4 0 --- Number of Reallocated Logical Sectors 0x03 0x028 4 0 --- Read Recovery Attempts 0x03 0x030 4 2 --- Number of Mechanical Start Failures 0x04 ===== = = === == General Errors Statistics (rev 1) == 0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors 0x04 0x010 4 83 --- Resets Between Cmd Acceptance and Completion 0x05 ===== = = === == Temperature Statistics (rev 1) == 0x05 0x008 1 28 --- Current Temperature 0x05 0x010 1 31 N-- Average Short Term Temperature 0x05 0x018 1 30 N-- Average Long Term Temperature 0x05 0x020 1 43 --- Highest Temperature 0x05 0x028 1 12 --- Lowest Temperature 0x05 0x030 1 39 N-- Highest Average Short Term Temperature 0x05 0x038 1 0 N-- Lowest Average Short Term Temperature 0x05 0x040 1 33 N-- Highest Average Long Term Temperature 0x05 0x048 1 0 N-- Lowest Average Long Term Temperature 0x05 0x050 4 0 --- Time in Over-Temperature 0x05 0x058 1 60 --- Specified Maximum Operating Temperature 0x05 0x060 4 0 --- Time in Under-Temperature 0x05 0x068 1 0 --- Specified Minimum Operating Temperature 0x06 ===== = = === == Transport Statistics (rev 1) == 0x06 0x008 4 1381 --- Number of Hardware Resets 0x06 0x010 4 735 --- Number of ASR Events 0x06 0x018 4 0 --- Number of Interface CRC Errors |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 3 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS /dev/da0 smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p5 amd64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Red Device Model: WDC WD30EFRX-68EUZN0 Serial Number: -- LU WWN Device Id: 5 0014ee ... Firmware Version: 82.00A82 User Capacity: 3,000,592,982,016 bytes [3.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 5400 rpm Device is: In smartctl database 7.3/5528 ATA Version is: ACS-2 (minor revision not indicated) SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Sat Jan 11 13:47:04 2025 EET SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (40500) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 406) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x703d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0 3 Spin_Up_Time POS--K 177 175 021 - 6125 4 Start_Stop_Count -O--CK 100 100 000 - 879 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 032 032 000 - 49960 10 Spin_Retry_Count -O--CK 100 100 000 - 0 11 Calibration_Retry_Count -O--CK 100 100 000 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 775 192 Power-Off_Retract_Count -O--CK 200 200 000 - 262 193 Load_Cycle_Count -O--CK 199 199 000 - 4336 194 Temperature_Celsius -O---K 127 108 000 - 23 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 100 253 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 6 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x21 GPL R/O 1 Write stream error log 0x22 GPL R/O 1 Read stream error log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log 0xa8-0xb7 GPL,SL VS 1 Device vendor specific log 0xbd GPL,SL VS 1 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xc1 GPL VS 93 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (6 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 2609 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 258 (0x0102) Device State: Active (0) Current Temperature: 22 Celsius Power Cycle Min/Max Temperature: 17/22 Celsius Lifetime Min/Max Temperature: 2/42 Celsius Under/Over Temperature Limit Count: 0/0 Vendor specific: 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -41/85 Celsius Temperature History Size (Index): 478 (156) Index Estimated Time Temperature Celsius 157 2025-01-11 05:50 27 ******** ... ..(315 skipped). .. ******** 473 2025-01-11 11:06 27 ******** 474 2025-01-11 11:07 ? - 475 2025-01-11 11:08 17 - 476 2025-01-11 11:09 17 - 477 2025-01-11 11:10 18 - ... ..( 2 skipped). .. - 2 2025-01-11 11:13 18 - 3 2025-01-11 11:14 19 - 4 2025-01-11 11:15 19 - 5 2025-01-11 11:16 20 * 6 2025-01-11 11:17 20 * 7 2025-01-11 11:18 21 ** ... ..( 4 skipped). .. ** 12 2025-01-11 11:23 21 ** 13 2025-01-11 11:24 22 *** ... ..( 2 skipped). .. *** 16 2025-01-11 11:27 22 *** 17 2025-01-11 11:28 27 ******** ... ..(138 skipped). .. ******** 156 2025-01-11 13:47 27 ******** SCT Error Recovery Control: Read: 70 (7.0 seconds) Write: 70 (7.0 seconds) Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 1 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 2 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x8000 4 1195 Vendor specific /dev/da1 smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p5 amd64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Red Device Model: WDC WD30EFRX-68EUZN0 Serial Number: -- LU WWN Device Id: 5 0014ee ... Firmware Version: 82.00A82 User Capacity: 3,000,592,982,016 bytes [3.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 5400 rpm Device is: In smartctl database 7.3/5528 ATA Version is: ACS-2 (minor revision not indicated) SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Sat Jan 11 13:47:04 2025 EET SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (40320) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 404) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x703d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 43 3 Spin_Up_Time POS--K 174 172 021 - 6266 4 Start_Stop_Count -O--CK 100 100 000 - 880 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 032 032 000 - 49959 10 Spin_Retry_Count -O--CK 100 100 000 - 0 11 Calibration_Retry_Count -O--CK 100 100 000 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 777 192 Power-Off_Retract_Count -O--CK 200 200 000 - 265 193 Load_Cycle_Count -O--CK 199 199 000 - 4336 194 Temperature_Celsius -O---K 128 111 000 - 22 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 100 253 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 1 200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 6 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x21 GPL R/O 1 Write stream error log 0x22 GPL R/O 1 Read stream error log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log 0xa8-0xb7 GPL,SL VS 1 Device vendor specific log 0xbd GPL,SL VS 1 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xc1 GPL VS 93 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (6 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 2608 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 258 (0x0102) Device State: Active (0) Current Temperature: 22 Celsius Power Cycle Min/Max Temperature: 16/22 Celsius Lifetime Min/Max Temperature: 2/40 Celsius Under/Over Temperature Limit Count: 0/0 Vendor specific: 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -41/85 Celsius Temperature History Size (Index): 478 (84) Index Estimated Time Temperature Celsius 85 2025-01-11 05:50 27 ******** ... ..( 21 skipped). .. ******** 107 2025-01-11 06:12 27 ******** 108 2025-01-11 06:13 26 ******* 109 2025-01-11 06:14 26 ******* 110 2025-01-11 06:15 27 ******** ... ..( 2 skipped). .. ******** 113 2025-01-11 06:18 27 ******** 114 2025-01-11 06:19 26 ******* ... ..( 47 skipped). .. ******* 162 2025-01-11 07:07 26 ******* 163 2025-01-11 07:08 27 ******** 164 2025-01-11 07:09 26 ******* 165 2025-01-11 07:10 27 ******** ... ..( 5 skipped). .. ******** 171 2025-01-11 07:16 27 ******** 172 2025-01-11 07:17 26 ******* 173 2025-01-11 07:18 27 ******** ... ..( 3 skipped). .. ******** 177 2025-01-11 07:22 27 ******** 178 2025-01-11 07:23 26 ******* ... ..( 47 skipped). .. ******* 226 2025-01-11 08:11 26 ******* 227 2025-01-11 08:12 27 ******** ... ..( 2 skipped). .. ******** 230 2025-01-11 08:15 27 ******** 231 2025-01-11 08:16 26 ******* ... ..(169 skipped). .. ******* 401 2025-01-11 11:06 26 ******* 402 2025-01-11 11:07 ? - 403 2025-01-11 11:08 16 - 404 2025-01-11 11:09 17 - 405 2025-01-11 11:10 17 - 406 2025-01-11 11:11 17 - 407 2025-01-11 11:12 18 - 408 2025-01-11 11:13 18 - 409 2025-01-11 11:14 18 - 410 2025-01-11 11:15 19 - 411 2025-01-11 11:16 19 - 412 2025-01-11 11:17 20 * 413 2025-01-11 11:18 20 * 414 2025-01-11 11:19 20 * 415 2025-01-11 11:20 21 ** ... ..( 4 skipped). .. ** 420 2025-01-11 11:25 21 ** 421 2025-01-11 11:26 22 *** 422 2025-01-11 11:27 22 *** 423 2025-01-11 11:28 26 ******* ... ..( 3 skipped). .. ******* 427 2025-01-11 11:32 26 ******* 428 2025-01-11 11:33 27 ******** ... ..( 49 skipped). .. ******** 0 2025-01-11 12:23 27 ******** 1 2025-01-11 12:24 26 ******* ... ..( 78 skipped). .. ******* 80 2025-01-11 13:43 26 ******* 81 2025-01-11 13:44 27 ******** ... ..( 2 skipped). .. ******** 84 2025-01-11 13:47 27 ******** SCT Error Recovery Control: Read: 70 (7.0 seconds) Write: 70 (7.0 seconds) Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 1 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 2 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x8000 4 1195 Vendor specific /dev/da2 smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p5 amd64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Red Device Model: WDC WD30EFRX-68EUZN0 Serial Number: -- LU WWN Device Id: 5 0014ee ... Firmware Version: 82.00A82 User Capacity: 3,000,592,982,016 bytes [3.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 5400 rpm Device is: In smartctl database 7.3/5528 ATA Version is: ACS-2 (minor revision not indicated) SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Sat Jan 11 13:47:04 2025 EET SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (39840) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 399) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x703d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0 3 Spin_Up_Time POS--K 174 173 021 - 6266 4 Start_Stop_Count -O--CK 100 100 000 - 710 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 037 037 000 - 46257 10 Spin_Retry_Count -O--CK 100 100 000 - 0 11 Calibration_Retry_Count -O--CK 100 100 000 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 607 192 Power-Off_Retract_Count -O--CK 200 200 000 - 209 193 Load_Cycle_Count -O--CK 199 199 000 - 4050 194 Temperature_Celsius -O---K 128 113 000 - 22 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 100 253 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 6 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x21 GPL R/O 1 Write stream error log 0x22 GPL R/O 1 Read stream error log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log 0xa8-0xb7 GPL,SL VS 1 Device vendor specific log 0xbd GPL,SL VS 1 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xc1 GPL VS 93 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (6 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 258 (0x0102) Device State: Active (0) Current Temperature: 22 Celsius Power Cycle Min/Max Temperature: 16/22 Celsius Lifetime Min/Max Temperature: 2/37 Celsius Under/Over Temperature Limit Count: 0/0 Vendor specific: 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -41/85 Celsius Temperature History Size (Index): 478 (334) Index Estimated Time Temperature Celsius 335 2025-01-11 05:50 27 ******** ... ..( 45 skipped). .. ******** 381 2025-01-11 06:36 27 ******** 382 2025-01-11 06:37 26 ******* ... ..( 3 skipped). .. ******* 386 2025-01-11 06:41 26 ******* 387 2025-01-11 06:42 27 ******** ... ..(113 skipped). .. ******** 23 2025-01-11 08:36 27 ******** 24 2025-01-11 08:37 ? - 25 2025-01-11 08:38 16 - 26 2025-01-11 08:39 17 - 27 2025-01-11 08:40 17 - 28 2025-01-11 08:41 18 - ... ..( 2 skipped). .. - 31 2025-01-11 08:44 18 - 32 2025-01-11 08:45 19 - 33 2025-01-11 08:46 19 - 34 2025-01-11 08:47 20 * 35 2025-01-11 08:48 20 * 36 2025-01-11 08:49 21 ** ... ..( 4 skipped). .. ** 41 2025-01-11 08:54 21 ** 42 2025-01-11 08:55 22 *** 43 2025-01-11 08:56 22 *** 44 2025-01-11 08:57 22 *** 45 2025-01-11 08:58 27 ******** ... ..( 76 skipped). .. ******** 122 2025-01-11 10:15 27 ******** 123 2025-01-11 10:16 26 ******* ... ..( 19 skipped). .. ******* 143 2025-01-11 10:36 26 ******* 144 2025-01-11 10:37 27 ******** ... ..(189 skipped). .. ******** 334 2025-01-11 13:47 27 ******** SCT Error Recovery Control: Read: 70 (7.0 seconds) Write: 70 (7.0 seconds) Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 1 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 2 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x8000 4 1195 Vendor specific


Hardware for Linux and BSD

GitHub