Probe #5bcd236c4a of Samsung 305E4A

Log: smartctl

/dev/ada0 smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p6 amd64] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Samsung based SSDs Device Model: Samsung SSD 860 EVO 250GB Serial Number: -- LU WWN Device Id: 5 002538 ... Firmware Version: RVT04B6Q User Capacity: 250,059,350,016 bytes [250 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches TRIM Command: Available, deterministic, zeroed Device is: In smartctl database 7.3/5319 ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5 SATA Version is: SATA 3.2, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Sun Mar 12 10:06:44 2023 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x80) Offline data collection activity was never started. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x53) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 85) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0 9 Power_On_Hours -O--CK 099 099 000 - 1230 12 Power_Cycle_Count -O--CK 099 099 000 - 692 177 Wear_Leveling_Count PO--C- 098 098 000 - 28 179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0 181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0 182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0 183 Runtime_Bad_Block PO--C- 100 100 010 - 0 187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0 190 Airflow_Temperature_Cel -O--CK 060 048 000 - 40 195 ECC_Error_Rate -O-RC- 200 200 000 - 0 199 CRC_Error_Count -OSRCK 100 100 000 - 0 235 POR_Recovery_Count -O--C- 099 099 000 - 323 241 Total_LBAs_Written -O--CK 099 099 000 - 5942845218 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 1 Comprehensive SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x04 GPL,SL R/O 8 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x13 GPL R/O 1 SATA NCQ Send and Receive log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa1 SL VS 16 Device vendor specific log 0xa5 SL VS 16 Device vendor specific log 0xce SL VS 16 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Aborted by host 90% 2 - # 2 Short offline Aborted by host 90% 2 - # 3 Short offline Aborted by host 90% 2 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing 256 0 65535 Read_scanning was never started Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 256 (0x0100) Device State: Active (0) Current Temperature: 40 Celsius Power Cycle Min/Max Temperature: 40/40 Celsius Lifetime Min/Max Temperature: 23/52 Celsius Specified Max Operating Temperature: 70 Celsius Under/Over Temperature Limit Count: 0/0 SMART Status: 0xc24f (PASSED) SCT Temperature History Version: 2 Temperature Sampling Period: 10 minutes Temperature Logging Interval: 10 minutes Min/Max recommended Temperature: 0/70 Celsius Min/Max Temperature Limit: 0/70 Celsius Temperature History Size (Index): 128 (57) Index Estimated Time Temperature Celsius 58 2023-03-11 12:50 ? - 59 2023-03-11 13:00 50 ******************************* 60 2023-03-11 13:10 49 ****************************** 61 2023-03-11 13:20 50 ******************************* 62 2023-03-11 13:30 52 ********************************* 63 2023-03-11 13:40 42 *********************** 64 2023-03-11 13:50 ? - 65 2023-03-11 14:00 44 ************************* 66 2023-03-11 14:10 44 ************************* 67 2023-03-11 14:20 48 ***************************** 68 2023-03-11 14:30 46 *************************** 69 2023-03-11 14:40 44 ************************* 70 2023-03-11 14:50 48 ***************************** 71 2023-03-11 15:00 46 *************************** 72 2023-03-11 15:10 42 *********************** 73 2023-03-11 15:20 44 ************************* 74 2023-03-11 15:30 41 ********************** 75 2023-03-11 15:40 ? - 76 2023-03-11 15:50 47 **************************** 77 2023-03-11 16:00 44 ************************* 78 2023-03-11 16:10 43 ************************ 79 2023-03-11 16:20 ? - 80 2023-03-11 16:30 48 ***************************** 81 2023-03-11 16:40 ? - 82 2023-03-11 16:50 ? - 83 2023-03-11 17:00 50 ******************************* 84 2023-03-11 17:10 49 ****************************** 85 2023-03-11 17:20 49 ****************************** 86 2023-03-11 17:30 48 ***************************** 87 2023-03-11 17:40 52 ********************************* 88 2023-03-11 17:50 45 ************************** 89 2023-03-11 18:00 47 **************************** 90 2023-03-11 18:10 44 ************************* 91 2023-03-11 18:20 ? - 92 2023-03-11 18:30 34 *************** 93 2023-03-11 18:40 36 ***************** 94 2023-03-11 18:50 37 ****************** 95 2023-03-11 19:00 39 ******************** 96 2023-03-11 19:10 42 *********************** 97 2023-03-11 19:20 40 ********************* ... ..( 3 skipped). .. ********************* 101 2023-03-11 20:00 40 ********************* 102 2023-03-11 20:10 44 ************************* 103 2023-03-11 20:20 42 *********************** 104 2023-03-11 20:30 40 ********************* 105 2023-03-11 20:40 40 ********************* 106 2023-03-11 20:50 41 ********************** ... ..( 3 skipped). .. ********************** 110 2023-03-11 21:30 41 ********************** 111 2023-03-11 21:40 42 *********************** 112 2023-03-11 21:50 ? - ... ..( 2 skipped). .. - 115 2023-03-11 22:20 ? - 116 2023-03-11 22:30 33 ************** 117 2023-03-11 22:40 36 ***************** 118 2023-03-11 22:50 ? - 119 2023-03-11 23:00 37 ****************** 120 2023-03-11 23:10 37 ****************** 121 2023-03-11 23:20 38 ******************* 122 2023-03-11 23:30 ? - 123 2023-03-11 23:40 ? - 124 2023-03-11 23:50 39 ******************** ... ..( 4 skipped). .. ******************** 1 2023-03-12 00:40 39 ******************** 2 2023-03-12 00:50 40 ********************* 3 2023-03-12 01:00 39 ******************** 4 2023-03-12 01:10 38 ******************* ... ..( 8 skipped). .. ******************* 13 2023-03-12 02:40 38 ******************* 14 2023-03-12 02:50 ? - 15 2023-03-12 03:00 37 ****************** 16 2023-03-12 03:10 38 ******************* 17 2023-03-12 03:20 ? - 18 2023-03-12 03:30 39 ******************** 19 2023-03-12 03:40 ? - 20 2023-03-12 03:50 31 ************ 21 2023-03-12 04:00 34 *************** 22 2023-03-12 04:10 35 **************** 23 2023-03-12 04:20 ? - 24 2023-03-12 04:30 37 ****************** 25 2023-03-12 04:40 37 ****************** 26 2023-03-12 04:50 38 ******************* 27 2023-03-12 05:00 38 ******************* 28 2023-03-12 05:10 38 ******************* 29 2023-03-12 05:20 ? - 30 2023-03-12 05:30 38 ******************* 31 2023-03-12 05:40 47 **************************** 32 2023-03-12 05:50 43 ************************ 33 2023-03-12 06:00 ? - 34 2023-03-12 06:10 40 ********************* 35 2023-03-12 06:20 44 ************************* 36 2023-03-12 06:30 48 ***************************** 37 2023-03-12 06:40 48 ***************************** 38 2023-03-12 06:50 42 *********************** 39 2023-03-12 07:00 41 ********************** 40 2023-03-12 07:10 ? - 41 2023-03-12 07:20 39 ******************** 42 2023-03-12 07:30 39 ******************** 43 2023-03-12 07:40 ? - 44 2023-03-12 07:50 ? - 45 2023-03-12 08:00 40 ********************* ... ..( 11 skipped). .. ********************* 57 2023-03-12 10:00 40 ********************* SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 1) == 0x01 0x008 4 692 --- Lifetime Power-On Resets 0x01 0x010 4 1230 --- Power-on Hours 0x01 0x018 6 5942845218 --- Logical Sectors Written 0x01 0x020 6 54344060 --- Number of Write Commands 0x01 0x028 6 3993903053 --- Logical Sectors Read 0x01 0x030 6 57992906 --- Number of Read Commands 0x01 0x038 6 3102000 --- Date and Time TimeStamp 0x04 ===== = = === == General Errors Statistics (rev 1) == 0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors 0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion 0x05 ===== = = === == Temperature Statistics (rev 1) == 0x05 0x008 1 40 --- Current Temperature 0x05 0x020 1 52 --- Highest Temperature 0x05 0x028 1 23 --- Lowest Temperature 0x05 0x058 1 70 --- Specified Maximum Operating Temperature 0x06 ===== = = === == Transport Statistics (rev 1) == 0x06 0x008 4 4003 --- Number of Hardware Resets 0x06 0x010 4 0 --- Number of ASR Events 0x06 0x018 4 0 --- Number of Interface CRC Errors 0x07 ===== = = === == Solid State Device Statistics (rev 1) == 0x07 0x008 1 1 N-- Percentage Used Endurance Indicator |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 27 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 27 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC /dev/ada1 smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p6 amd64] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Blue Mobile Device Model: WDC WD5000LPCX-24VHAT0 Serial Number: -- LU WWN Device Id: 5 0014ee ... Firmware Version: 02.01A02 User Capacity: 500,107,862,016 bytes [500 GB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 5400 rpm Form Factor: 2.5 inches Device is: In smartctl database 7.3/5319 ATA Version is: ACS-3 T13/2161-D revision 5 SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Sun Mar 12 10:06:44 2023 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM level is: 96 (intermediate level with standby) Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x80) Offline data collection activity was never started. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 8820) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 102) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x3035) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0 3 Spin_Up_Time POS--K 154 144 021 - 1300 4 Start_Stop_Count -O--CK 078 078 000 - 22405 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 089 089 000 - 8264 10 Spin_Retry_Count -O--CK 100 100 000 - 0 11 Calibration_Retry_Count -O--CK 100 100 000 - 0 12 Power_Cycle_Count -O--CK 099 099 000 - 1287 192 Power-Off_Retract_Count -O--CK 200 200 000 - 164 193 Load_Cycle_Count -O--CK 172 172 000 - 85363 194 Temperature_Celsius -O---K 107 092 000 - 36 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 100 253 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 6 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log 0xa8-0xb6 GPL,SL VS 1 Device vendor specific log 0xb7 GPL,SL VS 48 Device vendor specific log 0xbd GPL,SL VS 1 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xc1 GPL VS 93 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (6 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 258 (0x0102) Device State: Active (0) Current Temperature: 36 Celsius Power Cycle Min/Max Temperature: 35/38 Celsius Lifetime Min/Max Temperature: 18/51 Celsius Under/Over Temperature Limit Count: 0/0 Vendor specific: 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -41/85 Celsius Temperature History Size (Index): 128 (100) Index Estimated Time Temperature Celsius 101 2023-03-12 07:59 36 ***************** ... ..( 28 skipped). .. ***************** 2 2023-03-12 08:28 36 ***************** 3 2023-03-12 08:29 ? - 4 2023-03-12 08:30 36 ***************** 5 2023-03-12 08:31 36 ***************** 6 2023-03-12 08:32 36 ***************** 7 2023-03-12 08:33 ? - 8 2023-03-12 08:34 36 ***************** 9 2023-03-12 08:35 36 ***************** 10 2023-03-12 08:36 ? - 11 2023-03-12 08:37 36 ***************** 12 2023-03-12 08:38 36 ***************** 13 2023-03-12 08:39 36 ***************** 14 2023-03-12 08:40 35 **************** 15 2023-03-12 08:41 ? - 16 2023-03-12 08:42 35 **************** ... ..( 4 skipped). .. **************** 21 2023-03-12 08:47 35 **************** 22 2023-03-12 08:48 36 ***************** ... ..( 62 skipped). .. ***************** 85 2023-03-12 09:51 36 ***************** 86 2023-03-12 09:52 ? - 87 2023-03-12 09:53 36 ***************** 88 2023-03-12 09:54 36 ***************** 89 2023-03-12 09:55 36 ***************** 90 2023-03-12 09:56 ? - 91 2023-03-12 09:57 36 ***************** 92 2023-03-12 09:58 36 ***************** 93 2023-03-12 09:59 35 **************** 94 2023-03-12 10:00 ? - 95 2023-03-12 10:01 35 **************** 96 2023-03-12 10:02 36 ***************** ... ..( 3 skipped). .. ***************** 100 2023-03-12 10:06 36 ***************** SCT Error Recovery Control command not supported Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 27 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 27 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x8000 4 7854 Vendor specific


Hardware for Linux and BSD

GitHub