Probe #4bce25bd89 of Lenovo ThinkPad X260 20F600...
Log: smartctl
/dev/ada0
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-STABLE amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: MTFDDAK480MBP-1AN1ZABHB
Serial Number: --
LU WWN Device Id: 5 00a075 ...
Firmware Version: M511
User Capacity: 480,103,981,056 bytes [480 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: Not in smartctl database 7.3/5528
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sun Sep 3 20:48:59 2023 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x80) Offline data collection activity
was never started.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 2235) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 6) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
5 Reallocated_Sector_Ct -O--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 100 100 000 - 13204
12 Power_Cycle_Count -O--CK 100 100 000 - 1194
171 Unknown_Attribute -O---K 100 100 000 - 0
172 Unknown_Attribute -O--CK 100 100 000 - 0
173 Unknown_Attribute -O--CK 100 100 000 - 32
174 Unknown_Attribute -O--CK 100 100 000 - 162
175 Program_Fail_Count_Chip -O--CK 100 100 000 - 0
181 Program_Fail_Cnt_Total -O---K 100 100 000 - 4844727567396
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
184 End-to-End_Error PO--CK 100 100 050 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
188 Command_Timeout -O--CK 100 100 000 - 0
194 Temperature_Celsius -O---K 065 053 000 - 35 (Min/Max 11/47)
198 Offline_Uncorrectable ----CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
201 Unknown_SSD_Attribute ---RC- 100 100 000 - 0
241 Total_LBAs_Written -O--CK 100 100 000 - 20898022571
242 Total_LBAs_Read -O--CK 100 100 000 - 21585390014
243 Unknown_Attribute -O--CK 100 100 000 - 39238473696
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 255 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x24 GPL R/O 429 Current Device Internal Status Data log
0x25 GPL R/O 145 Saved Device Internal Status Data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL VS 2000 Device vendor specific log
0xa0 SL VS 208 Device vendor specific log
0xa1-0xb5 GPL,SL VS 1 Device vendor specific log
0xb6 GPL VS 8193 Device vendor specific log
0xb6 SL VS 1 Device vendor specific log
0xb7-0xbf GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 80 Device vendor specific log
0xc1-0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Offline Completed without error 00% 13204 -
# 2 Vendor (0xff) Completed without error 00% 10180 -
# 3 Vendor (0xff) Completed without error 00% 6826 -
# 4 Short offline Completed without error 00% 6775 -
# 5 Offline Completed without error 00% 6774 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: Active (0)
Current Temperature: 35 Celsius
Power Cycle Min/Max Temperature: 35/35 Celsius
Lifetime Min/Max Temperature: 11/47 Celsius
Specified Max Operating Temperature: 55 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/55 Celsius
Min/Max Temperature Limit: -5/75 Celsius
Temperature History Size (Index): 478 (21)
Index Estimated Time Temperature Celsius
22 2023-09-03 12:51 43 ************************
... ..(434 skipped). .. ************************
457 2023-09-03 20:06 43 ************************
458 2023-09-03 20:07 ? -
459 2023-09-03 20:08 ? -
460 2023-09-03 20:09 ? -
461 2023-09-03 20:10 41 **********************
... ..( 15 skipped). .. **********************
477 2023-09-03 20:26 41 **********************
0 2023-09-03 20:27 43 ************************
... ..( 20 skipped). .. ************************
21 2023-09-03 20:48 43 ************************
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 1194 --- Lifetime Power-On Resets
0x01 0x010 4 13204 --- Power-on Hours
0x01 0x018 6 20898022571 --- Logical Sectors Written
0x01 0x020 6 486949081 --- Number of Write Commands
0x01 0x028 6 21585390014 --- Logical Sectors Read
0x01 0x030 6 530608530 --- Number of Read Commands
0x01 0x038 6 47536471080 --- Date and Time TimeStamp
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 35 --- Current Temperature
0x05 0x010 1 37 --- Average Short Term Temperature
0x05 0x018 1 37 --- Average Long Term Temperature
0x05 0x020 1 47 --- Highest Temperature
0x05 0x028 1 11 --- Lowest Temperature
0x05 0x030 1 43 --- Highest Average Short Term Temperature
0x05 0x038 1 21 --- Lowest Average Short Term Temperature
0x05 0x040 1 39 --- Highest Average Long Term Temperature
0x05 0x048 1 23 --- Lowest Average Long Term Temperature
0x05 0x050 4 - --- Time in Over-Temperature
0x05 0x058 1 55 --- Specified Maximum Operating Temperature
0x05 0x060 4 - --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 154 --- Number of Hardware Resets
0x06 0x010 4 0 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 0 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x000a 4 2 Device-to-host register FISes sent due to a COMRESET