/dev/ada0
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p12-HBSD amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SanDisk based SSDs
Device Model: SanDisk SSD i100 32GB
Serial Number: --
LU WWN Device Id: 5 001b44 ...
Firmware Version: 11.56.00
User Capacity: 32,017,047,552 bytes [32.0 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 1.8 inches
TRIM Command: Available, deterministic
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Fri Feb 5 17:01:03 2021 -04
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 120) seconds.
Offline data collection
capabilities: (0x51) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 7) minutes.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct -O---- 100 100 000 - 0
9 Power_On_Hours -O---- 100 100 000 - 33871
12 Power_Cycle_Count -O---- 100 100 000 - 68
171 Program_Fail_Count -O---- 100 100 000 - 0
172 Erase_Fail_Count -O---- 100 100 000 - 0
173 Avg_Write/Erase_Count -O---- 100 100 000 - 328
174 Unexpect_Power_Loss_Ct -O---- 100 100 000 - 58
187 Reported_Uncorrect -O---- 100 100 000 - 12
230 Perc_Write/Erase_Count -O---- 100 100 000 - 1093
232 Perc_Avail_Resrvd_Space PO---- 100 100 005 - 0
234 Perc_Write/Erase_Ct_BC -O---- 100 100 000 - 10000
241 Total_LBAs_Written -O---- 100 100 000 - 114807888
242 Total_LBAs_Read -O---- 100 100 000 - 14325389
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x03 GPL,SL R/O 16 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 GPL,SL R/O 1 SMART self-test log
0x10 GPL,SL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 GPL,SL VS 1 Device vendor specific log
0xa2 GPL,SL VS 2 Device vendor specific log
0xa3 GPL,SL VS 1 Device vendor specific log
SMART Extended Comprehensive Error Log Version: 1 (16 sectors)
Device Error Count: 12
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 12 [11] occurred at disk power-on lifetime: 31505 hours (1312 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 02 c3 0a a8 00 00
Error: UNC
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
2f 00 00 00 01 00 00 00 00 00 10 00 00 26d+08:23:01.892 READ LOG EXT
2f 00 00 00 01 00 00 00 00 00 10 00 00 26d+08:23:01.855 READ LOG EXT
2f 00 00 00 01 00 00 00 00 00 10 00 00 26d+08:23:01.807 READ LOG EXT
06 00 01 00 01 00 00 00 00 00 00 40 00 26d+08:22:59.884 DATA SET MANAGEMENT
06 00 01 00 01 00 00 00 00 00 00 40 00 26d+08:22:59.882 DATA SET MANAGEMENT
Error 11 [10] occurred at disk power-on lifetime: 31505 hours (1312 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 02 c3 0a a8 00 00
Error: UNC
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
2f 00 00 00 01 00 00 00 00 00 10 00 00 26d+08:23:01.855 READ LOG EXT
2f 00 00 00 01 00 00 00 00 00 10 00 00 26d+08:23:01.807 READ LOG EXT
06 00 01 00 01 00 00 00 00 00 00 40 00 26d+08:22:59.884 DATA SET MANAGEMENT
06 00 01 00 01 00 00 00 00 00 00 40 00 26d+08:22:59.882 DATA SET MANAGEMENT
06 00 01 00 01 00 00 00 00 00 00 40 00 26d+08:22:59.869 DATA SET MANAGEMENT
Error 10 [9] occurred at disk power-on lifetime: 31505 hours (1312 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 02 c3 0a a8 00 00
Error: UNC
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
2f 00 00 00 01 00 00 00 00 00 10 00 00 26d+08:23:01.807 READ LOG EXT
06 00 01 00 01 00 00 00 00 00 00 40 00 26d+08:22:59.884 DATA SET MANAGEMENT
06 00 01 00 01 00 00 00 00 00 00 40 00 26d+08:22:59.882 DATA SET MANAGEMENT
06 00 01 00 01 00 00 00 00 00 00 40 00 26d+08:22:59.869 DATA SET MANAGEMENT
06 00 01 00 01 00 00 00 00 00 00 40 00 26d+08:22:59.868 DATA SET MANAGEMENT
Error 9 [8] occurred at disk power-on lifetime: 31505 hours (1312 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 02 c3 0a a8 40 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
06 00 01 00 01 00 00 00 00 00 00 40 00 26d+08:22:59.884 DATA SET MANAGEMENT
06 00 01 00 01 00 00 00 00 00 00 40 00 26d+08:22:59.882 DATA SET MANAGEMENT
06 00 01 00 01 00 00 00 00 00 00 40 00 26d+08:22:59.869 DATA SET MANAGEMENT
06 00 01 00 01 00 00 00 00 00 00 40 00 26d+08:22:59.868 DATA SET MANAGEMENT
06 00 01 00 01 00 00 00 00 00 00 40 00 26d+08:22:59.428 DATA SET MANAGEMENT
Error 8 [7] occurred at disk power-on lifetime: 31482 hours (1311 days + 18 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 02 c3 0a a8 40 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
06 00 01 00 01 00 00 00 00 00 00 40 00 25d+09:16:55.315 DATA SET MANAGEMENT
06 00 01 00 01 00 00 00 00 00 00 40 00 25d+09:16:55.313 DATA SET MANAGEMENT
06 00 01 00 01 00 00 00 00 00 00 40 00 25d+09:16:55.305 DATA SET MANAGEMENT
06 00 01 00 01 00 00 00 00 00 00 40 00 25d+09:16:55.303 DATA SET MANAGEMENT
06 00 01 00 01 00 00 00 00 00 00 40 00 25d+09:16:55.288 DATA SET MANAGEMENT
Error 7 [6] occurred at disk power-on lifetime: 31337 hours (1305 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 02 c3 0a a8 40 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
06 00 01 00 01 00 00 00 00 00 00 40 00 19d+08:29:12.624 DATA SET MANAGEMENT
06 00 01 00 02 00 00 00 00 00 00 40 00 19d+08:29:12.620 DATA SET MANAGEMENT
06 00 01 00 01 00 00 00 00 00 00 40 00 19d+08:29:12.601 DATA SET MANAGEMENT
06 00 01 00 01 00 00 00 00 00 00 40 00 19d+08:29:12.183 DATA SET MANAGEMENT
06 00 01 00 01 00 00 00 00 00 00 40 00 19d+08:29:12.177 DATA SET MANAGEMENT
Error 6 [5] occurred at disk power-on lifetime: 31265 hours (1302 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 02 c3 0a a8 40 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
06 00 01 00 01 00 00 00 00 00 00 40 00 16d+08:20:13.534 DATA SET MANAGEMENT
06 00 01 00 01 00 00 00 00 00 00 40 00 16d+08:20:02.746 DATA SET MANAGEMENT
06 00 01 00 01 00 00 00 00 00 00 40 00 16d+08:20:02.696 DATA SET MANAGEMENT
06 00 01 00 01 00 00 00 00 00 00 40 00 16d+08:20:02.216 DATA SET MANAGEMENT
06 00 01 00 01 00 00 00 00 00 00 40 00 16d+08:20:02.216 DATA SET MANAGEMENT
Error 5 [4] occurred at disk power-on lifetime: 31169 hours (1298 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 02 c3 0a a8 00 00
Error: UNC
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
2f 00 00 00 01 00 00 00 00 00 10 00 00 12d+08:19:17.678 READ LOG EXT
2f 00 00 00 01 00 00 00 00 00 10 00 00 12d+08:19:17.640 READ LOG EXT
06 00 01 00 01 00 00 00 00 00 00 40 00 12d+08:18:58.659 DATA SET MANAGEMENT
06 00 01 00 01 00 00 00 00 00 00 40 00 12d+08:18:58.609 DATA SET MANAGEMENT
06 00 01 00 01 00 00 00 00 00 00 40 00 12d+08:18:58.333 DATA SET MANAGEMENT
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 45 --- Current Temperature
0x05 0x010 1 46 --- Average Short Term Temperature
0x05 0x018 1 - --- Average Long Term Temperature
0x05 0x020 1 61 --- Highest Temperature
0x05 0x028 1 28 --- Lowest Temperature
0x05 0x030 1 55 --- Highest Average Short Term Temperature
0x05 0x038 1 55 --- Lowest Average Short Term Temperature
0x05 0x040 1 50 --- Highest Average Long Term Temperature
0x05 0x048 1 50 --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 95 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 10 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0009 2 28 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 24 Device-to-host register FISes sent due to a COMRESET
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0001 2 0 Command failed due to ICRC error