Probe #42b9e61011 of Dell 08NPPY A00 Desktop Computer (OptiPlex 3050)
Log: smartctl
/dev/nvd0
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p3 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: SAMSUNG MZVLW512HMJP-000L7
Serial Number: --
Firmware Version: 6L7QCXY7
PCI Vendor/Subsystem ID: 0x144d
IEEE OUI Identifier: 0x002538
Total NVM Capacity: 512,110,190,592 [512 GB]
Unallocated NVM Capacity: 0
Controller ID: 2
NVMe Version: 1.2
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
Namespace 1 Utilization: 121,469,755,392 [121 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 002538 ...
Local Time is: Wed Nov 8 13:51:49 2023 CET
Firmware Updates (0x16): 3 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg
Warning Comp. Temp. Threshold: 69 Celsius
Critical Comp. Temp. Threshold: 72 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 7.60W - - 0 0 0 0 0 0
1 + 6.00W - - 1 1 1 1 0 0
2 + 5.10W - - 2 2 2 2 0 0
3 - 0.0400W - - 3 3 3 3 210 1500
4 - 0.0050W - - 4 4 4 4 2200 6000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 45 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 8%
Data Units Read: 100,265,012 [51.3 TB]
Data Units Written: 125,359,145 [64.1 TB]
Host Read Commands: 860,968,102
Host Write Commands: 1,141,586,135
Controller Busy Time: 9,589
Power Cycles: 1,984
Power On Hours: 7,593
Unsafe Shutdowns: 756
Media and Data Integrity Errors: 0
Error Information Log Entries: 4,949
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 45 Celsius
Temperature Sensor 2: 75 Celsius
Error Information (NVMe Log 0x01, 16 of 64 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message
0 4949 0 0x0018 0x4004 0x02c 0 0 - Invalid Field in Command
1 4948 0 0x0017 0x4004 0x02c 0 0 - Invalid Field in Command
2 4947 0 0x0015 0x4212 0x028 0 - - Invalid Log Page
3 4946 0 0x0002 0x4004 0x028 0 0 - Invalid Field in Command
4 4945 0 0x0018 0x4004 0x02c 0 0 - Invalid Field in Command
5 4944 0 0x0017 0x4004 0x02c 0 0 - Invalid Field in Command
6 4943 0 0x0015 0x4212 0x028 0 - - Invalid Log Page
7 4942 0 0x0002 0x4004 0x028 0 0 - Invalid Field in Command
8 4941 0 0x0018 0x4004 0x02c 0 0 - Invalid Field in Command
9 4940 0 0x0017 0x4004 0x02c 0 0 - Invalid Field in Command
10 4939 0 0x0015 0x4212 0x028 0 - - Invalid Log Page
11 4938 0 0x0002 0x4004 0x028 0 0 - Invalid Field in Command
12 4937 0 0x0018 0x4004 0x02c 0 0 - Invalid Field in Command
13 4936 0 0x0017 0x4004 0x02c 0 0 - Invalid Field in Command
14 4935 0 0x0015 0x4212 0x028 0 - - Invalid Log Page
15 4934 0 0x0002 0x4004 0x028 0 0 - Invalid Field in Command
... (48 entries not read)
Self-test Log (NVMe Log 0x06)
Self-test status: Short self-test in progress (78% completed)
No Self-tests Logged