/dev/ada0
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: ST240FN0021
Serial Number: --
LU WWN Device Id: 5 000c50 ...
Firmware Version: B550
User Capacity: 240,057,409,536 bytes [240 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available
Device is: Not in smartctl database 7.3/5528
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Thu Jun 20 10:04:44 2024 AEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
Read SMART Thresholds failed: Input/output error
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x19) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0002) Does not save SMART data before
entering power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 21) minutes.
SMART Attributes Data Structure revision number: 0
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 166 001 --- - 0
5 Reallocated_Sector_Ct PO--CK 100 100 --- - 10
9 Power_On_Hours -O--CK 100 091 --- - 76
12 Power_Cycle_Count -O--CK 100 100 --- - 852
171 Unknown_Attribute -O--CK 100 100 --- - 0
172 Unknown_Attribute -O--CK 100 100 --- - 0
181 Program_Fail_Cnt_Total -O--CK 100 100 --- - 0
182 Erase_Fail_Count_Total -O--CK 100 100 --- - 0
194 Temperature_Celsius -O---K 024 000 --- - 24 (Min/Max 0/48)
201 Unknown_SSD_Attribute -O--CK 100 099 --- - 0
204 Soft_ECC_Correction -O--CK 100 100 --- - 0
231 Unknown_SSD_Attribute PO--C- 097 097 --- - 4
234 Unknown_Attribute -O--CK 100 100 --- - 55663
241 Total_LBAs_Written -O--CK 100 100 --- - 9203
242 Total_LBAs_Read -O--CK 100 100 --- - 4604
250 Read_Error_Retry_Rate -O--CK 100 100 --- - 12110
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x07 GPL,SL R/O 2 Extended self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa8 GPL VS 1041 Device vendor specific log
0xa8 SL VS 255 Device vendor specific log
0xb7 GPL,SL VS 4 Device vendor specific log
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
Device Error Count: 65535 (device log contains only the most recent 20 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 65535 [18] occurred at disk power-on lifetime: 76 hours (3 days + 4 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 00 00 00 00 00 00 00 e0 08
Error: ABRT
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b0 00 d1 00 01 00 00 00 c2 4f 01 40 08 01:24:07.710 SMART READ ATTRIBUTE THRESHOLDS [OBS-4]
b0 00 d0 00 01 00 00 00 c2 4f 00 40 08 01:24:07.710 SMART READ DATA
ec 00 00 00 01 00 00 00 00 00 00 40 08 01:24:07.700 IDENTIFY DEVICE
60 00 58 00 50 00 00 06 09 be c0 40 08 01:24:07.690 READ FPDMA QUEUED
60 00 60 00 48 00 00 06 08 69 00 40 08 01:24:07.680 READ FPDMA QUEUED
Error 65534 [17] occurred at disk power-on lifetime: 64 hours (2 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 ff 00 00 00 00 00 00 e0 08
Error: ABRT
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b0 00 d1 00 01 00 00 00 c2 4f 01 00 08 00:37:57.920 SMART READ ATTRIBUTE THRESHOLDS [OBS-4]
b0 00 d0 00 01 00 00 00 c2 4f 00 00 08 00:37:57.920 SMART READ DATA
ec 00 00 00 01 00 00 00 00 00 00 00 08 00:37:57.840 IDENTIFY DEVICE
e5 00 00 00 00 00 00 00 00 00 00 00 08 00:37:57.840 CHECK POWER MODE
ec 00 00 00 01 00 00 00 00 00 00 00 08 00:37:57.840 IDENTIFY DEVICE
Error 65533 [16] occurred at disk power-on lifetime: 64 hours (2 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 ff 00 00 00 00 00 00 e0 08
Error: ABRT
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b0 00 d1 00 01 00 00 00 c2 4f 01 00 08 00:33:09.090 SMART READ ATTRIBUTE THRESHOLDS [OBS-4]
b0 00 d0 00 01 00 00 00 c2 4f 00 00 08 00:33:09.090 SMART READ DATA
ec 00 00 00 01 00 00 00 00 00 00 00 08 00:33:09.020 IDENTIFY DEVICE
e5 00 00 00 00 00 00 00 00 00 00 00 08 00:33:09.020 CHECK POWER MODE
ec 00 00 00 01 00 00 00 00 00 00 00 08 00:33:09.010 IDENTIFY DEVICE
Error 65532 [15] occurred at disk power-on lifetime: 63 hours (2 days + 15 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 ff 00 00 00 00 00 00 e0 08
Error: ABRT
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b0 00 d1 00 01 00 00 00 c2 4f 01 00 08 00:26:33.310 SMART READ ATTRIBUTE THRESHOLDS [OBS-4]
b0 00 d0 00 01 00 00 00 c2 4f 00 00 08 00:26:33.310 SMART READ DATA
ec 00 00 00 01 00 00 00 00 00 00 00 08 00:26:33.230 IDENTIFY DEVICE
e5 00 00 00 00 00 00 00 00 00 00 00 08 00:26:33.230 CHECK POWER MODE
ec 00 00 00 01 00 00 00 00 00 00 00 08 00:26:33.230 IDENTIFY DEVICE
Error 65531 [14] occurred at disk power-on lifetime: 63 hours (2 days + 15 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 ff 00 00 00 00 00 00 e0 08
Error: ABRT
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b0 00 d1 00 01 00 00 00 c2 4f 01 00 08 00:25:42.550 SMART READ ATTRIBUTE THRESHOLDS [OBS-4]
b0 00 d0 00 01 00 00 00 c2 4f 00 00 08 00:25:42.550 SMART READ DATA
ec 00 00 00 01 00 00 00 00 00 00 00 08 00:25:42.470 IDENTIFY DEVICE
e5 00 00 00 00 00 00 00 00 00 00 00 08 00:25:42.470 CHECK POWER MODE
ec 00 00 00 01 00 00 00 00 00 00 00 08 00:25:42.470 IDENTIFY DEVICE
Error 65530 [13] occurred at disk power-on lifetime: 59 hours (2 days + 11 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 ff 00 00 00 00 00 00 e0 08
Error: ABRT
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b0 00 d1 00 01 00 00 00 c2 4f 00 00 08 00:00:33.930 SMART READ ATTRIBUTE THRESHOLDS [OBS-4]
ec 00 00 00 01 00 00 00 00 00 00 00 08 00:00:33.930 IDENTIFY DEVICE
e5 00 00 00 00 00 00 00 00 00 00 00 08 00:00:33.930 CHECK POWER MODE
60 00 08 00 b8 00 00 00 00 29 e8 40 08 00:00:33.920 READ FPDMA QUEUED
60 00 40 00 b0 00 00 00 00 08 20 40 08 00:00:33.910 READ FPDMA QUEUED
Error 65529 [12] occurred at disk power-on lifetime: 59 hours (2 days + 11 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 02 00 00 00 c2 4f 00 e0 08
Error: ABRT
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b0 00 d1 00 01 00 00 00 c2 4f 01 00 08 00:00:32.940 SMART READ ATTRIBUTE THRESHOLDS [OBS-4]
b0 00 d0 00 01 00 00 00 c2 4f 00 00 08 00:00:32.940 SMART READ DATA
b0 00 da 00 00 00 00 00 c2 4f 00 00 08 00:00:32.940 SMART RETURN STATUS
b0 00 d8 00 00 00 00 00 c2 4f 01 00 08 00:00:32.940 SMART ENABLE OPERATIONS
ec 00 00 00 01 00 00 00 00 00 00 00 08 00:00:32.910 IDENTIFY DEVICE
Error 65528 [11] occurred at disk power-on lifetime: 59 hours (2 days + 11 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 ff 00 00 00 00 00 00 e0 08
Error: ABRT
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b0 00 d1 00 01 00 00 00 c2 4f 00 00 08 00:05:59.750 SMART READ ATTRIBUTE THRESHOLDS [OBS-4]
ec 00 00 00 01 00 00 00 00 00 00 00 08 00:05:59.750 IDENTIFY DEVICE
e5 00 00 00 00 00 00 00 00 00 00 00 08 00:05:59.740 CHECK POWER MODE
60 00 08 00 08 00 00 00 00 29 e8 40 08 00:05:59.740 READ FPDMA QUEUED
60 00 40 00 00 00 00 00 00 08 20 40 08 00:05:59.730 READ FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (2 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
Selective Self-tests/Logging not supported
SCT Commands not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 852 --- Lifetime Power-On Resets
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 7 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC