Probe #3c6b444246 of MSI H81M-P33 Desktop Computer (MS-7817)

Log: smartctl

/dev/ada0 smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p11 amd64] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Caviar Black Device Model: WDC WD1001FALS-00J7B0 Serial Number: -- LU WWN Device Id: 5 0014ee ... Firmware Version: 05.00K05 User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS (minor revision not indicated) SATA Version is: SATA 2.5, 3.0 Gb/s Local Time is: Sun Feb 28 11:45:34 2021 PST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Disabled APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (19200) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 221) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x303f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0 3 Spin_Up_Time POS--K 253 253 021 - 6058 4 Start_Stop_Count -O--CK 100 100 000 - 127 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 100 253 051 - 0 9 Power_On_Hours -O--CK 001 001 000 - 107886 10 Spin_Retry_Count -O--CK 100 100 051 - 0 11 Calibration_Retry_Count -O--CK 100 100 051 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 127 192 Power-Off_Retract_Count -O--CK 200 200 000 - 88 193 Load_Cycle_Count -O--CK 200 200 000 - 127 194 Temperature_Celsius -O---K 102 095 000 - 48 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 200 200 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 1 200 Multi_Zone_Error_Rate ---R-- 200 200 051 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 6 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log 0xa8-0xb7 GPL,SL VS 1 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xc1 GPL VS 24 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (6 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 42345 - # 2 Extended offline Completed without error 00% 42178 - # 3 Short offline Completed without error 00% 42007 - # 4 Extended offline Completed without error 00% 42007 - # 5 Extended offline Completed without error 00% 41844 - # 6 Extended offline Completed without error 00% 41674 - # 7 Short offline Completed without error 00% 41668 - # 8 Extended offline Completed without error 00% 41506 - # 9 Short offline Completed without error 00% 41343 - #10 Extended offline Completed without error 00% 41339 - #11 Extended offline Interrupted (host reset) 20% 41250 - #12 Extended offline Completed without error 00% 41085 - #13 Short offline Completed without error 00% 41080 - #14 Extended offline Completed without error 00% 40917 - #15 Extended offline Completed without error 00% 40758 - #16 Short offline Completed without error 00% 40749 - #17 Extended offline Completed without error 00% 40587 - #18 Short offline Completed without error 00% 40419 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 2 SCT Version (vendor specific): 258 (0x0102) Device State: SMART Off-line Data Collection executing in background (4) Current Temperature: 48 Celsius Power Cycle Min/Max Temperature: 43/51 Celsius Lifetime Min/Max Temperature: ?/56 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -41/85 Celsius Temperature History Size (Index): 128 (80) Index Estimated Time Temperature Celsius 81 2021-02-28 09:38 46 *************************** ... ..( 70 skipped). .. *************************** 24 2021-02-28 10:49 46 *************************** 25 2021-02-28 10:50 47 **************************** ... ..( 15 skipped). .. **************************** 41 2021-02-28 11:06 47 **************************** 42 2021-02-28 11:07 48 ***************************** ... ..( 37 skipped). .. ***************************** 80 2021-02-28 11:45 48 ***************************** SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x000a 2 3 Device-to-host register FISes sent due to a COMRESET 0x8000 4 3344981 Vendor specific /dev/ada1 smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p11 amd64] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Caviar Black Device Model: WDC WD1001FALS-00J7B0 Serial Number: -- LU WWN Device Id: 5 0014ee ... Firmware Version: 05.00K05 User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS (minor revision not indicated) SATA Version is: SATA 2.5, 3.0 Gb/s Local Time is: Sun Feb 28 11:45:34 2021 PST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Disabled APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (18600) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 214) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x303f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0 3 Spin_Up_Time POS--K 253 253 021 - 6450 4 Start_Stop_Count -O--CK 100 100 000 - 133 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 051 - 0 9 Power_On_Hours -O--CK 001 001 000 - 107885 10 Spin_Retry_Count -O--CK 100 100 051 - 0 11 Calibration_Retry_Count -O--CK 100 100 051 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 133 192 Power-Off_Retract_Count -O--CK 200 200 000 - 95 193 Load_Cycle_Count -O--CK 200 200 000 - 133 194 Temperature_Celsius -O---K 099 090 000 - 51 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 200 200 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 200 200 051 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 6 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log 0xa8-0xb7 GPL,SL VS 1 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xc1 GPL VS 24 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (6 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 42345 - # 2 Extended offline Completed without error 00% 42181 - # 3 Extended offline Completed without error 00% 42012 - # 4 Extended offline Completed without error 00% 41842 - # 5 Extended offline Completed without error 00% 41674 - # 6 Extended offline Completed without error 00% 41507 - # 7 Extended offline Completed without error 00% 41340 - # 8 Extended offline Completed without error 00% 41253 - # 9 Extended offline Completed without error 00% 41086 - #10 Extended offline Completed without error 00% 40921 - #11 Extended offline Completed without error 00% 40758 - #12 Extended offline Completed without error 00% 40588 - #13 Extended offline Completed without error 00% 40420 - #14 Extended offline Completed without error 00% 40252 - #15 Extended offline Completed without error 00% 40084 - #16 Extended offline Completed without error 00% 39916 - #17 Extended offline Completed without error 00% 39750 - #18 Extended offline Completed without error 00% 39581 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 2 SCT Version (vendor specific): 258 (0x0102) Device State: SMART Off-line Data Collection executing in background (4) Current Temperature: 51 Celsius Power Cycle Min/Max Temperature: 45/54 Celsius Lifetime Min/Max Temperature: ?/60 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -41/85 Celsius Temperature History Size (Index): 128 (15) Index Estimated Time Temperature Celsius 16 2021-02-28 09:38 50 ******************************* ... ..( 86 skipped). .. ******************************* 103 2021-02-28 11:05 50 ******************************* 104 2021-02-28 11:06 51 ******************************** ... ..( 38 skipped). .. ******************************** 15 2021-02-28 11:45 51 ******************************** SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x000a 2 6 Device-to-host register FISes sent due to a COMRESET 0x8000 4 3344928 Vendor specific /dev/ada2 smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p11 amd64] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Samsung based SSDs Device Model: Samsung SSD 850 EVO 1TB Serial Number: -- LU WWN Device Id: 5 002538 ... Firmware Version: EMT02B6Q User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches TRIM Command: Available Device is: In smartctl database [for details use: -P show] ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Sun Feb 28 11:45:35 2021 PST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 243) Self-test routine in progress... 30% of test remaining. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x53) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 512) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0 9 Power_On_Hours -O--CK 093 093 000 - 32171 12 Power_Cycle_Count -O--CK 099 099 000 - 341 177 Wear_Leveling_Count PO--C- 099 099 000 - 11 179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0 181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0 182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0 183 Runtime_Bad_Block PO--C- 100 099 010 - 0 187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0 190 Airflow_Temperature_Cel -O--CK 058 047 000 - 42 195 ECC_Error_Rate -O-RC- 200 200 000 - 0 199 CRC_Error_Count -OSRCK 100 100 000 - 0 235 POR_Recovery_Count -O--C- 099 099 000 - 73 241 Total_LBAs_Written -O--CK 099 099 000 - 84999753146 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 1 Comprehensive SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x13 GPL R/O 1 SATA NCQ Send and Receive log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa1 SL VS 16 Device vendor specific log 0xa5 SL VS 16 Device vendor specific log 0xce SL VS 16 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 32005 - # 2 Extended offline Completed without error 00% 31837 - # 3 Extended offline Completed without error 00% 31669 - # 4 Extended offline Completed without error 00% 31501 - # 5 Extended offline Completed without error 00% 31333 - # 6 Extended offline Completed without error 00% 31165 - # 7 Extended offline Completed without error 00% 31079 - # 8 Extended offline Completed without error 00% 30911 - # 9 Extended offline Completed without error 00% 30743 - #10 Extended offline Completed without error 00% 30579 - #11 Extended offline Completed without error 00% 30411 - #12 Extended offline Completed without error 00% 30243 - #13 Extended offline Completed without error 00% 30075 - #14 Extended offline Completed without error 00% 29907 - #15 Extended offline Completed without error 00% 29739 - #16 Extended offline Completed without error 00% 29571 - #17 Extended offline Completed without error 00% 29403 - #18 Extended offline Completed without error 00% 29235 - #19 Extended offline Completed without error 00% 29067 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing 255 0 65535 Read_scanning was never started Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 256 (0x0100) Device State: DST executing in background (3) Current Temperature: 42 Celsius Power Cycle Min/Max Temperature: 37/48 Celsius Lifetime Min/Max Temperature: 21/53 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 10 minutes Min/Max recommended Temperature: 0/70 Celsius Min/Max Temperature Limit: 0/70 Celsius Temperature History Size (Index): 128 (111) Index Estimated Time Temperature Celsius 112 2021-02-27 14:30 42 *********************** 113 2021-02-27 14:40 42 *********************** 114 2021-02-27 14:50 41 ********************** 115 2021-02-27 15:00 41 ********************** 116 2021-02-27 15:10 42 *********************** 117 2021-02-27 15:20 42 *********************** 118 2021-02-27 15:30 41 ********************** ... ..( 3 skipped). .. ********************** 122 2021-02-27 16:10 41 ********************** 123 2021-02-27 16:20 42 *********************** 124 2021-02-27 16:30 41 ********************** ... ..( 3 skipped). .. ********************** 0 2021-02-27 17:10 41 ********************** 1 2021-02-27 17:20 42 *********************** 2 2021-02-27 17:30 41 ********************** ... ..( 57 skipped). .. ********************** 60 2021-02-28 03:10 41 ********************** 61 2021-02-28 03:20 42 *********************** ... ..( 11 skipped). .. *********************** 73 2021-02-28 05:20 42 *********************** 74 2021-02-28 05:30 43 ************************ 75 2021-02-28 05:40 45 ************************** 76 2021-02-28 05:50 42 *********************** ... ..( 20 skipped). .. *********************** 97 2021-02-28 09:20 42 *********************** 98 2021-02-28 09:30 41 ********************** ... ..( 3 skipped). .. ********************** 102 2021-02-28 10:10 41 ********************** 103 2021-02-28 10:20 42 *********************** 104 2021-02-28 10:30 41 ********************** 105 2021-02-28 10:40 41 ********************** 106 2021-02-28 10:50 41 ********************** 107 2021-02-28 11:00 42 *********************** ... ..( 3 skipped). .. *********************** 111 2021-02-28 11:40 42 *********************** SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 11 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 11 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC /dev/ada3 smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p11 amd64] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Caviar Black Device Model: WDC WD1001FALS-00J7B0 Serial Number: -- LU WWN Device Id: 5 0014ee ... Firmware Version: 05.00K05 User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS (minor revision not indicated) SATA Version is: SATA 2.5, 3.0 Gb/s Local Time is: Sun Feb 28 11:45:35 2021 PST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Disabled APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (19200) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 221) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x303f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0 3 Spin_Up_Time POS--K 253 253 021 - 6266 4 Start_Stop_Count -O--CK 100 100 000 - 126 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 100 253 051 - 0 9 Power_On_Hours -O--CK 001 001 000 - 107882 10 Spin_Retry_Count -O--CK 100 100 051 - 0 11 Calibration_Retry_Count -O--CK 100 100 051 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 126 192 Power-Off_Retract_Count -O--CK 200 200 000 - 87 193 Load_Cycle_Count -O--CK 200 200 000 - 126 194 Temperature_Celsius -O---K 098 093 000 - 52 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 200 200 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 200 200 051 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 6 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log 0xa8-0xb7 GPL,SL VS 1 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xc1 GPL VS 24 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (6 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 42343 - # 2 Extended offline Completed without error 00% 42178 - # 3 Extended offline Completed without error 00% 42010 - # 4 Extended offline Completed without error 00% 41840 - # 5 Extended offline Completed without error 00% 41672 - # 6 Extended offline Completed without error 00% 41505 - # 7 Extended offline Completed without error 00% 41337 - # 8 Extended offline Completed without error 00% 41251 - # 9 Extended offline Completed without error 00% 41084 - #10 Extended offline Completed without error 00% 40918 - #11 Extended offline Completed without error 00% 40755 - #12 Extended offline Completed without error 00% 40585 - #13 Extended offline Completed without error 00% 40417 - #14 Extended offline Completed without error 00% 40250 - #15 Extended offline Completed without error 00% 40082 - #16 Extended offline Completed without error 00% 39914 - #17 Extended offline Completed without error 00% 39748 - #18 Extended offline Completed without error 00% 39581 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 2 SCT Version (vendor specific): 258 (0x0102) Device State: SMART Off-line Data Collection executing in background (4) Current Temperature: 52 Celsius Power Cycle Min/Max Temperature: 45/54 Celsius Lifetime Min/Max Temperature: ?/57 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -41/85 Celsius Temperature History Size (Index): 128 (67) Index Estimated Time Temperature Celsius 68 2021-02-28 09:38 50 ******************************* ... ..( 75 skipped). .. ******************************* 16 2021-02-28 10:54 50 ******************************* 17 2021-02-28 10:55 51 ******************************** ... ..( 23 skipped). .. ******************************** 41 2021-02-28 11:19 51 ******************************** 42 2021-02-28 11:20 52 ********************************* ... ..( 24 skipped). .. ********************************* 67 2021-02-28 11:45 52 ********************************* SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x000a 2 6 Device-to-host register FISes sent due to a COMRESET 0x8000 4 3344940 Vendor specific /dev/ada4 smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p11 amd64] (local build) Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: Samsung SSD 860 QVO 1TB Serial Number: -- LU WWN Device Id: 5 002538 ... Firmware Version: RVQ01B6Q User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches TRIM Command: Available, deterministic, zeroed Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5 SATA Version is: SATA 3.2, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Sun Feb 28 11:45:36 2021 PST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x53) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 85) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0 9 Power_On_Hours -O--CK 097 097 000 - 10149 12 Power_Cycle_Count -O--CK 099 099 000 - 16 177 Wear_Leveling_Count PO--C- 095 095 000 - 37 179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0 181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0 182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0 183 Runtime_Bad_Block PO--C- 100 100 010 - 0 187 Reported_Uncorrect -O--CK 100 100 000 - 0 190 Airflow_Temperature_Cel -O--CK 053 044 000 - 47 195 Hardware_ECC_Recovered -O-RC- 200 200 000 - 0 199 UDMA_CRC_Error_Count -OSRCK 100 100 000 - 0 235 Unknown_Attribute -O--C- 099 099 000 - 1 241 Total_LBAs_Written -O--CK 099 099 000 - 38571480866 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 1 Comprehensive SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x04 GPL,SL R/O 8 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x13 GPL R/O 1 SATA NCQ Send and Receive log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa1 SL VS 16 Device vendor specific log 0xa5 SL VS 16 Device vendor specific log 0xce-0xcf SL VS 16 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing 256 0 65535 Read_scanning was never started Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 256 (0x0100) Device State: Active (0) Current Temperature: 47 Celsius Power Cycle Min/Max Temperature: 34/52 Celsius Lifetime Min/Max Temperature: 40/56 Celsius Specified Max Operating Temperature: 70 Celsius Under/Over Temperature Limit Count: 0/0 SMART Status: 0xc24f (PASSED) SCT Temperature History Version: 2 Temperature Sampling Period: 10 minutes Temperature Logging Interval: 10 minutes Min/Max recommended Temperature: 0/70 Celsius Min/Max Temperature Limit: 0/70 Celsius Temperature History Size (Index): 128 (116) Index Estimated Time Temperature Celsius 117 2021-02-27 14:30 47 **************************** ... ..( 13 skipped). .. **************************** 3 2021-02-27 16:50 47 **************************** 4 2021-02-27 17:00 46 *************************** 5 2021-02-27 17:10 47 **************************** ... ..( 2 skipped). .. **************************** 8 2021-02-27 17:40 47 **************************** 9 2021-02-27 17:50 46 *************************** 10 2021-02-27 18:00 46 *************************** 11 2021-02-27 18:10 47 **************************** 12 2021-02-27 18:20 47 **************************** 13 2021-02-27 18:30 46 *************************** ... ..( 38 skipped). .. *************************** 52 2021-02-28 01:00 46 *************************** 53 2021-02-28 01:10 47 **************************** ... ..( 32 skipped). .. **************************** 86 2021-02-28 06:40 47 **************************** 87 2021-02-28 06:50 46 *************************** 88 2021-02-28 07:00 46 *************************** 89 2021-02-28 07:10 47 **************************** 90 2021-02-28 07:20 47 **************************** 91 2021-02-28 07:30 46 *************************** ... ..( 2 skipped). .. *************************** 94 2021-02-28 08:00 46 *************************** 95 2021-02-28 08:10 47 **************************** ... ..( 2 skipped). .. **************************** 98 2021-02-28 08:40 47 **************************** 99 2021-02-28 08:50 46 *************************** 100 2021-02-28 09:00 46 *************************** 101 2021-02-28 09:10 47 **************************** 102 2021-02-28 09:20 47 **************************** 103 2021-02-28 09:30 46 *************************** ... ..( 2 skipped). .. *************************** 106 2021-02-28 10:00 46 *************************** 107 2021-02-28 10:10 47 **************************** 108 2021-02-28 10:20 47 **************************** 109 2021-02-28 10:30 47 **************************** 110 2021-02-28 10:40 46 *************************** 111 2021-02-28 10:50 47 **************************** ... ..( 4 skipped). .. **************************** 116 2021-02-28 11:40 47 **************************** SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 1) == 0x01 0x008 4 16 --- Lifetime Power-On Resets 0x01 0x010 4 10149 --- Power-on Hours 0x01 0x018 6 38571480866 --- Logical Sectors Written 0x01 0x020 6 952482957 --- Number of Write Commands 0x01 0x028 6 21184351620 --- Logical Sectors Read 0x01 0x030 6 187667928 --- Number of Read Commands 0x01 0x038 6 2243000 --- Date and Time TimeStamp 0x04 ===== = = === == General Errors Statistics (rev 1) == 0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors 0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion 0x05 ===== = = === == Temperature Statistics (rev 1) == 0x05 0x008 1 47 --- Current Temperature 0x05 0x020 1 56 --- Highest Temperature 0x05 0x028 1 40 --- Lowest Temperature 0x05 0x058 1 70 --- Specified Maximum Operating Temperature 0x06 ===== = = === == Transport Statistics (rev 1) == 0x06 0x008 4 247 --- Number of Hardware Resets 0x06 0x010 4 0 --- Number of ASR Events 0x06 0x018 4 0 --- Number of Interface CRC Errors 0x07 ===== = = === == Solid State Device Statistics (rev 1) == 0x07 0x008 1 4 N-- Percentage Used Endurance Indicator |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description


Hardware for Linux and BSD

GitHub