Probe #2affd2540a of Acer Aspire XC-830 Desktop Computer (Aspire XC-830-UW90)
Log: smartctl
/dev/nvd0
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p7 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: KINGSTON RBUSNS8154P3256GJ1
Serial Number: --
Firmware Version: E8FK12.3
PCI Vendor/Subsystem ID: 0x2646
IEEE OUI Identifier: 0x0026b7
Total NVM Capacity: 256,060,514,304 [256 GB]
Unallocated NVM Capacity: 0
Controller ID: 0
NVMe Version: 1.2
Number of Namespaces: 1
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 0026b7 ...
Local Time is: Sat Mar 25 17:16:18 2023 CDT
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0007): Security Format Frmw_DL
Optional NVM Commands (0x001e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
Log Page Attributes (0x04): Ext_Get_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 84 Celsius
Critical Comp. Temp. Threshold: 88 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 7.90W 0.0790W - 0 0 0 0 600 600
1 + 7.90W 0.0790W - 0 0 0 0 600 600
2 + 7.90W 0.0790W - 0 0 0 0 600 600
3 - 0.1000W 0.0790W - 3 3 3 3 1000 1000
4 - 0.0050W 0.0790W - 4 4 4 4 400000 90000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 31 Celsius
Available Spare: 100%
Available Spare Threshold: 100%
Percentage Used: 0%
Data Units Read: 557,995 [285 GB]
Data Units Written: 1,464,550 [749 GB]
Host Read Commands: 7,058,753
Host Write Commands: 20,546,192
Controller Busy Time: 26
Power Cycles: 132
Power On Hours: 1,872
Unsafe Shutdowns: 25
Media and Data Integrity Errors: 0
Error Information Log Entries: 38
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 2: 31 Celsius
Error Information (NVMe Log 0x01, 16 of 16 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS
0 38 0 0x0007 0x0005 - 33555456 0 -
1 37 0 0x0002 0x0005 - 208 0 -
2 36 0 0x0002 0x0005 - 208 0 -
3 35 0 0x0002 0x0005 - 208 0 -
4 34 0 0x0002 0x0005 - 208 0 -
5 33 0 0x0002 0x0005 - 208 0 -
6 32 0 0x0002 0x0005 - 208 0 -
7 31 0 0x0002 0x0005 - 208 0 -
8 30 0 0x0007 0x0005 - 33555456 0 -
9 29 0 0x0002 0x0005 - 208 0 -
10 28 0 0x0002 0x0005 - 208 0 -
11 27 0 0x0002 0x0005 - 208 0 -
12 26 0 0x0007 0x0005 - 33555456 0 -
13 25 0 0x0002 0x0005 - 208 0 -
14 24 0 0x0007 0x0005 - 33555456 0 -
15 23 0 0x0002 0x0005 - 208 0 -