Probe #2a8e07ec62 of HP 8299 Desktop Computer (EliteDesk 800 G3 SFF)
Log: smartctl
/dev/nvd0
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p9 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: SAMSUNG MZVLW256HEHP-000H1
Serial Number: --
Firmware Version: CXB73H1Q
PCI Vendor/Subsystem ID: 0x144d
IEEE OUI Identifier: 0x002538
Total NVM Capacity: 256,060,514,304 [256 GB]
Unallocated NVM Capacity: 0
Controller ID: 2
NVMe Version: 1.2
Number of Namespaces: 1
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
Namespace 1 Utilization: 61,831,057,408 [61.8 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 002538 ...
Local Time is: Sat Feb 10 08:40:55 2024 CET
Firmware Updates (0x16): 3 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg
Warning Comp. Temp. Threshold: 68 Celsius
Critical Comp. Temp. Threshold: 71 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 7.60W - - 0 0 0 0 0 0
1 + 6.00W - - 1 1 1 1 0 0
2 + 5.10W - - 2 2 2 2 0 0
3 - 0.0400W - - 3 3 3 3 210 1500
4 - 0.0050W - - 4 4 4 4 2200 6000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 32 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 4%
Data Units Read: 7,642,016 [3.91 TB]
Data Units Written: 37,508,472 [19.2 TB]
Host Read Commands: 103,577,398
Host Write Commands: 485,298,427
Controller Busy Time: 773
Power Cycles: 2,655
Power On Hours: 6,604
Unsafe Shutdowns: 25
Media and Data Integrity Errors: 0
Error Information Log Entries: 977
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 32 Celsius
Temperature Sensor 2: 58 Celsius
Error Information (NVMe Log 0x01, 16 of 64 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message
0 977 0 0x0014 0x4016 0x004 0 1 - Invalid Namespace or Format
1 976 0 0x0014 0x4016 0x004 0 1 - Invalid Namespace or Format
2 975 0 0x0014 0x4016 0x004 0 1 - Invalid Namespace or Format
3 974 0 0x0014 0x4016 0x004 0 1 - Invalid Namespace or Format
4 973 0 0x0014 0x4016 0x004 0 1 - Invalid Namespace or Format
5 972 0 0x0014 0x4016 0x004 0 1 - Invalid Namespace or Format
6 971 0 0x0014 0x4016 0x004 0 1 - Invalid Namespace or Format
7 970 0 0x0014 0x4016 0x004 0 1 - Invalid Namespace or Format
8 969 0 0x0014 0x4016 0x004 0 1 - Invalid Namespace or Format
9 968 0 0x0014 0x4016 0x004 0 1 - Invalid Namespace or Format
10 967 0 0x0014 0x4016 0x004 0 1 - Invalid Namespace or Format
11 966 0 0x0014 0x4016 0x004 0 1 - Invalid Namespace or Format
12 965 0 0x0014 0x4016 0x004 0 1 - Invalid Namespace or Format
13 964 0 0x0014 0x4016 0x004 0 1 - Invalid Namespace or Format
14 963 0 0x0014 0x4016 0x004 0 1 - Invalid Namespace or Format
15 962 0 0x0014 0x4016 0x004 0 1 - Invalid Namespace or Format
... (48 entries not read)
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged