/dev/ada0
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p6 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital RE3 Serial ATA
Device Model: WDC WD5002ABYS-50B1B1
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 02.03B06
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 7200 rpm
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.5, 3.0 Gb/s
Local Time is: Mon Feb 20 23:14:49 2023 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 254 (maximum performance), recommended: 128
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 9480) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 112) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 239 239 021 - 1041
4 Start_Stop_Count -O--CK 100 100 000 - 140
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 001 001 000 - 80076
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 139
192 Power-Off_Retract_Count -O--CK 200 200 000 - 132
193 Load_Cycle_Count -O--CK 200 200 000 - 7
194 Temperature_Celsius -O---K 103 102 000 - 44
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb5 GPL,SL VS 1 Device vendor specific log
0xb6 GPL VS 1 Device vendor specific log
0xb7 GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 24 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 258 (0x0102)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 44 Celsius
Power Cycle Min/Max Temperature: 24/45 Celsius
Lifetime Min/Max Temperature: 43/45 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (42)
Index Estimated Time Temperature Celsius
43 2023-02-20 15:17 43 ************************
... ..( 30 skipped). .. ************************
74 2023-02-20 15:48 43 ************************
75 2023-02-20 15:49 44 *************************
... ..( 4 skipped). .. *************************
80 2023-02-20 15:54 44 *************************
81 2023-02-20 15:55 43 ************************
... ..( 79 skipped). .. ************************
161 2023-02-20 17:15 43 ************************
162 2023-02-20 17:16 44 *************************
... ..( 4 skipped). .. *************************
167 2023-02-20 17:21 44 *************************
168 2023-02-20 17:22 43 ************************
... ..( 5 skipped). .. ************************
174 2023-02-20 17:28 43 ************************
175 2023-02-20 17:29 44 *************************
176 2023-02-20 17:30 44 *************************
177 2023-02-20 17:31 43 ************************
... ..( 4 skipped). .. ************************
182 2023-02-20 17:36 43 ************************
183 2023-02-20 17:37 44 *************************
... ..( 38 skipped). .. *************************
222 2023-02-20 18:16 44 *************************
223 2023-02-20 18:17 43 ************************
... ..( 15 skipped). .. ************************
239 2023-02-20 18:33 43 ************************
240 2023-02-20 18:34 44 *************************
241 2023-02-20 18:35 44 *************************
242 2023-02-20 18:36 43 ************************
... ..( 30 skipped). .. ************************
273 2023-02-20 19:07 43 ************************
274 2023-02-20 19:08 44 *************************
... ..( 19 skipped). .. *************************
294 2023-02-20 19:28 44 *************************
295 2023-02-20 19:29 43 ************************
296 2023-02-20 19:30 43 ************************
297 2023-02-20 19:31 43 ************************
298 2023-02-20 19:32 44 *************************
299 2023-02-20 19:33 44 *************************
300 2023-02-20 19:34 43 ************************
... ..( 2 skipped). .. ************************
303 2023-02-20 19:37 43 ************************
304 2023-02-20 19:38 44 *************************
... ..( 15 skipped). .. *************************
320 2023-02-20 19:54 44 *************************
321 2023-02-20 19:55 43 ************************
... ..( 22 skipped). .. ************************
344 2023-02-20 20:18 43 ************************
345 2023-02-20 20:19 44 *************************
... ..( 9 skipped). .. *************************
355 2023-02-20 20:29 44 *************************
356 2023-02-20 20:30 43 ************************
... ..( 20 skipped). .. ************************
377 2023-02-20 20:51 43 ************************
378 2023-02-20 20:52 44 *************************
... ..( 8 skipped). .. *************************
387 2023-02-20 21:01 44 *************************
388 2023-02-20 21:02 43 ************************
... ..( 55 skipped). .. ************************
444 2023-02-20 21:58 43 ************************
445 2023-02-20 21:59 44 *************************
446 2023-02-20 22:00 44 *************************
447 2023-02-20 22:01 43 ************************
448 2023-02-20 22:02 43 ************************
449 2023-02-20 22:03 44 *************************
... ..( 21 skipped). .. *************************
471 2023-02-20 22:25 44 *************************
472 2023-02-20 22:26 43 ************************
... ..( 47 skipped). .. ************************
42 2023-02-20 23:14 43 ************************
SCT Error Recovery Control:
Read: 70 (7.0 seconds)
Write: 70 (7.0 seconds)
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
0x8000 4 193581 Vendor specific
/dev/ada1
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p6 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital RE3 Serial ATA
Device Model: WDC WD5002ABYS-50B1B1
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 02.03B06
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 7200 rpm
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.5, 3.0 Gb/s
Local Time is: Mon Feb 20 23:14:49 2023 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 254 (maximum performance), recommended: 128
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 9480) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 112) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 239 238 021 - 1050
4 Start_Stop_Count -O--CK 100 100 000 - 141
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 001 001 000 - 80074
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 140
192 Power-Off_Retract_Count -O--CK 200 200 000 - 133
193 Load_Cycle_Count -O--CK 200 200 000 - 7
194 Temperature_Celsius -O---K 104 102 000 - 43
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb5 GPL,SL VS 1 Device vendor specific log
0xb6 GPL VS 1 Device vendor specific log
0xb7 GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 24 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 258 (0x0102)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 43 Celsius
Power Cycle Min/Max Temperature: 23/45 Celsius
Lifetime Min/Max Temperature: 25/45 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (15)
Index Estimated Time Temperature Celsius
16 2023-02-20 15:17 43 ************************
... ..(476 skipped). .. ************************
15 2023-02-20 23:14 43 ************************
SCT Error Recovery Control:
Read: 70 (7.0 seconds)
Write: 70 (7.0 seconds)
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
0x8000 4 193580 Vendor specific