Probe #0cdc2b47b2 of Dell 0NW6H5 A00 Desktop Computer (OptiPlex 7050)

Log: smartctl

/dev/ada0 smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p8 amd64] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Intel 320 Series SSDs Device Model: INTEL SSDSA2CW080G3 Serial Number: -- LU WWN Device Id: 5 001517 ... Firmware Version: 4PC10362 User Capacity: 80,026,361,856 bytes [80.0 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device TRIM Command: Available, deterministic, zeroed Device is: In smartctl database 7.3/5319 ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 2.6, 3.0 Gb/s Local Time is: Wed Jun 28 22:33:05 2023 EDT SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Unexpected SCT status 0x0002 (action_code=4, function_code=2) Wt Cache Reorder: Unknown (SCT Feature Control command failed) === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 1) seconds. Offline data collection capabilities: (0x75) SMART execute Offline immediate. No Auto Offline data collection support. Abort Offline collection upon new command. No Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 1) minutes. Conveyance self-test routine recommended polling time: ( 1) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 5 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 3 Spin_Up_Time -----K 100 100 000 - 0 4 Start_Stop_Count ----CK 100 100 000 - 0 5 Reallocated_Sector_Ct -O--CK 100 100 000 - 0 9 Power_On_Hours -O--CK 100 100 000 - 60809 12 Power_Cycle_Count -O--CK 100 100 000 - 418 170 Reserve_Block_Count PO--CK 100 100 010 - 0 171 Program_Fail_Count -O--CK 100 100 000 - 0 172 Erase_Fail_Count -O--CK 100 100 000 - 0 183 SATA_Downshift_Count ----CK 100 100 000 - 0 184 End-to-End_Error -O--CK 100 100 090 - 0 187 Reported_Uncorrect -O--CK 100 100 000 - 0 192 Unsafe_Shutdown_Count -O--CK 100 100 000 - 393 199 CRC_Error_Count ----CK 100 100 000 - 0 225 Host_Writes_32MiB -O--CK 100 100 000 - 810778 226 Workld_Media_Wear_Indic -O--CK 100 100 000 - 14013 227 Workld_Host_Reads_Perc -O--CK 100 100 000 - 50 228 Workload_Minutes -O--CK 100 100 000 - 3648546 232 Available_Reservd_Space PO--CK 100 100 010 - 0 233 Media_Wearout_Indicator -O--CK 087 087 000 - 0 241 Host_Writes_32MiB -O--CK 100 100 000 - 810778 242 Host_Reads_32MiB -O--CK 100 100 000 - 821005 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning Log Directories not read due to '-F nologdir' option SMART Extended Comprehensive Error Log Version: 1 (2 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (2 sectors) Invalid Self-test Log index = 0x01a8 (reserved = 0x00) SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 1 (0x0001) Device State: Active (0) Current Temperature: ? Celsius Power Cycle Min/Max Temperature: ?/ ? Celsius Lifetime Min/Max Temperature: ?/ ? Celsius Under/Over Temperature Limit Count: 0/0 Read SCT Data Table failed: Input/output error Read SCT Temperature History failed SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 2) == 0x01 0x008 4 418 --- Lifetime Power-On Resets 0x01 0x010 4 60809 --- Power-on Hours 0x01 0x018 6 53135204642 --- Logical Sectors Written 0x01 0x020 6 1027700984 --- Number of Write Commands 0x01 0x028 6 53805428040 --- Logical Sectors Read 0x01 0x030 6 1785972057 --- Number of Read Commands 0x04 ===== = = === == General Errors Statistics (rev 1) == 0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors 0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion 0x06 ===== = = === == Transport Statistics (rev 1) == 0x06 0x008 4 5708 --- Number of Hardware Resets 0x06 0x010 4 72 --- Number of ASR Events 0x06 0x018 4 0 --- Number of Interface CRC Errors 0x07 ===== = = === == Solid State Device Statistics (rev 1) == 0x07 0x008 1 13 --- Percentage Used Endurance Indicator |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 4 0 Command failed due to ICRC error 0x0004 4 0 R_ERR response for host-to-device data FIS 0x0007 4 0 R_ERR response for host-to-device non-data FIS 0x0008 4 0 Device-to-host non-data FIS retries 0x0009 4 2 Transition from drive PhyRdy to drive PhyNRdy 0x000a 4 4 Device-to-host register FISes sent due to a COMRESET 0x000b 4 0 CRC errors within host-to-device FIS 0x000d 4 0 Non-CRC errors within host-to-device FIS 0x000f 4 0 R_ERR response for host-to-device data FIS, CRC 0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC /dev/nvd0 smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p8 amd64] (local build) Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Number: SPCC M.2 PCIe SSD Serial Number: -- Firmware Version: T1102A0L PCI Vendor/Subsystem ID: 0x126f IEEE OUI Identifier: 0x000001 Total NVM Capacity: 128,035,676,160 [128 GB] Unallocated NVM Capacity: 0 Controller ID: 1 NVMe Version: 1.3 Number of Namespaces: 1 Namespace 1 Size/Capacity: 128,035,676,160 [128 GB] Namespace 1 Formatted LBA Size: 512 Namespace 1 IEEE EUI-64: 000001 ... Local Time is: Wed Jun 28 22:33:05 2023 EDT Firmware Updates (0x12): 1 Slot, no Reset required Optional Admin Commands (0x0007): Security Format Frmw_DL Optional NVM Commands (0x0014): DS_Mngmt Sav/Sel_Feat Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg Maximum Data Transfer Size: 64 Pages Warning Comp. Temp. Threshold: 83 Celsius Critical Comp. Temp. Threshold: 85 Celsius Supported Power States St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat 0 + 6.00W - - 0 0 0 0 0 0 Supported LBA Sizes (NSID 0x1) Id Fmt Data Metadt Rel_Perf 0 + 512 0 0 === START OF SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED SMART/Health Information (NVMe Log 0x02) Critical Warning: 0x00 Temperature: 41 Celsius Available Spare: 100% Available Spare Threshold: 10% Percentage Used: 0% Data Units Read: 129,771 [66.4 GB] Data Units Written: 4,263,015 [2.18 TB] Host Read Commands: 3,169,097 Host Write Commands: 71,652,611 Controller Busy Time: 6,341 Power Cycles: 38 Power On Hours: 3,683 Unsafe Shutdowns: 29 Media and Data Integrity Errors: 0 Error Information Log Entries: 0 Warning Comp. Temperature Time: 0 Critical Comp. Temperature Time: 0 Error Information (NVMe Log 0x01, 16 of 64 entries) No Errors Logged


Hardware for Linux and BSD

GitHub