Probe #062a08c811 of Lenovo ThinkPad X240 20ALA0... Desktop Computer
Log: smartctl
/dev/sd0
smartctl 7.3 2022-02-28 r5338 [OpenBSD 7.1 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: JMicron/Maxiotek based SSDs
Device Model: NT-512
Serial Number: --
LU WWN Device Id: 5 000000 ...
Firmware Version: H190313
User Capacity: 512,110,190,592 bytes [512 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database 7.3/5319
ATA Version is: ACS-2 (minor revision not indicated)
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri Apr 22 21:32:07 2022 +10
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 33) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 2) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x0039) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 5446
12 Power_Cycle_Count 0x0012 100 100 000 Old_age Always - 580
167 Unknown_JMF_Attribute 0x0022 100 100 000 Old_age Always - 0
168 SATA_Phy_Error_Count 0x0012 100 100 000 Old_age Always - 0
169 Unknown_JMF_Attribute 0x0013 094 094 010 Pre-fail Always - 28311579
171 Unknown_Attribute 0x0032 000 000 000 Old_age Always - 0
172 Unknown_Attribute 0x0032 000 000 000 Old_age Always - 0
173 Erase_Count 0x0012 200 200 000 Old_age Always - 2 59 21
175 Bad_Cluster_Table_Count 0x0022 100 100 010 Old_age Always - 0
180 Unknown_JMF_Attribute 0x0033 100 100 000 Pre-fail Always - 7200
187 Unknown_JMF_Attribute 0x0032 100 000 000 Old_age Always - 0
192 Unexpect_Power_Loss_Ct 0x0012 100 100 000 Old_age Always - 73
194 Temperature_Celsius 0x0022 030 030 000 Old_age Always - 30 (Min/Max 10/50)
206 Unknown_SSD_Attribute 0x0032 200 200 000 Old_age Always - 2
207 Unknown_SSD_Attribute 0x0032 200 200 000 Old_age Always - 59
208 Unknown_SSD_Attribute 0x0032 200 200 000 Old_age Always - 21
209 Unknown_SSD_Attribute 0x0032 200 200 000 Old_age Always - 1230
210 Unknown_Attribute 0x0032 200 200 000 Old_age Always - 1247
211 Unknown_Attribute 0x0032 200 200 000 Old_age Always - 1131
231 Unknown_JMF_Attribute 0x0023 100 100 005 Pre-fail Always - 0
241 Total_LBAs_Written 0x0032 100 100 000 Old_age Always - 13969770765
242 Total_LBAs_Read 0x0032 100 100 000 Old_age Always - 38767938557
245 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.