Probe #043918562c of Dell 0NW6H5 A00 Desktop Computer (OptiPlex 7050)

Log: smartctl

/dev/nvd0 smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p7 amd64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Number: WD Red SN700 500GB Serial Number: -- Firmware Version: 111150WD PCI Vendor/Subsystem ID: 0x15b7 IEEE OUI Identifier: 0x001b44 Total NVM Capacity: 500,107,862,016 [500 GB] Unallocated NVM Capacity: 0 Controller ID: 8215 NVMe Version: 1.3 Number of Namespaces: 1 Namespace 1 Size/Capacity: 500,107,862,016 [500 GB] Namespace 1 Formatted LBA Size: 512 Namespace 1 IEEE EUI-64: 001b44 ... Local Time is: Tue Jan 30 19:48:45 2024 CET Firmware Updates (0x14): 2 Slots, no Reset required Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp Log Page Attributes (0x0e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Maximum Data Transfer Size: 128 Pages Warning Comp. Temp. Threshold: 84 Celsius Critical Comp. Temp. Threshold: 88 Celsius Namespace 1 Features (0x02): NA_Fields Supported Power States St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat 0 + 5.50W - - 0 0 0 0 0 0 1 + 3.50W - - 1 1 1 1 0 0 2 + 3.00W - - 2 2 2 2 0 0 3 - 0.0700W - - 3 3 3 3 4000 10000 4 - 0.0035W - - 4 4 4 4 4000 40000 Supported LBA Sizes (NSID 0x1) Id Fmt Data Metadt Rel_Perf 0 + 512 0 2 1 - 4096 0 1 === START OF SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED SMART/Health Information (NVMe Log 0x02) Critical Warning: 0x00 Temperature: 39 Celsius Available Spare: 100% Available Spare Threshold: 10% Percentage Used: 0% Data Units Read: 18,918 [9.68 GB] Data Units Written: 11,063,430 [5.66 TB] Host Read Commands: 795,484 Host Write Commands: 324,961,861 Controller Busy Time: 103 Power Cycles: 35 Power On Hours: 2,984 Unsafe Shutdowns: 24 Media and Data Integrity Errors: 0 Error Information Log Entries: 1 Warning Comp. Temperature Time: 0 Critical Comp. Temperature Time: 0 Error Information (NVMe Log 0x01, 16 of 256 entries) No Errors Logged Self-test Log (NVMe Log 0x06) Self-test status: No self-test in progress No Self-tests Logged /dev/nvd1 smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p7 amd64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Number: WD Red SN700 500GB Serial Number: -- Firmware Version: 111150WD PCI Vendor/Subsystem ID: 0x15b7 IEEE OUI Identifier: 0x001b44 Total NVM Capacity: 500,107,862,016 [500 GB] Unallocated NVM Capacity: 0 Controller ID: 8215 NVMe Version: 1.3 Number of Namespaces: 1 Namespace 1 Size/Capacity: 500,107,862,016 [500 GB] Namespace 1 Formatted LBA Size: 512 Namespace 1 IEEE EUI-64: 001b44 ... Local Time is: Tue Jan 30 19:48:45 2024 CET Firmware Updates (0x14): 2 Slots, no Reset required Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp Log Page Attributes (0x0e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Maximum Data Transfer Size: 128 Pages Warning Comp. Temp. Threshold: 84 Celsius Critical Comp. Temp. Threshold: 88 Celsius Namespace 1 Features (0x02): NA_Fields Supported Power States St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat 0 + 5.50W - - 0 0 0 0 0 0 1 + 3.50W - - 1 1 1 1 0 0 2 + 3.00W - - 2 2 2 2 0 0 3 - 0.0700W - - 3 3 3 3 4000 10000 4 - 0.0035W - - 4 4 4 4 4000 40000 Supported LBA Sizes (NSID 0x1) Id Fmt Data Metadt Rel_Perf 0 + 512 0 2 1 - 4096 0 1 === START OF SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED SMART/Health Information (NVMe Log 0x02) Critical Warning: 0x00 Temperature: 41 Celsius Available Spare: 100% Available Spare Threshold: 10% Percentage Used: 0% Data Units Read: 21,932 [11.2 GB] Data Units Written: 11,393,692 [5.83 TB] Host Read Commands: 906,216 Host Write Commands: 332,889,574 Controller Busy Time: 114 Power Cycles: 64 Power On Hours: 3,177 Unsafe Shutdowns: 48 Media and Data Integrity Errors: 0 Error Information Log Entries: 1 Warning Comp. Temperature Time: 0 Critical Comp. Temperature Time: 0 Error Information (NVMe Log 0x01, 16 of 256 entries) No Errors Logged Self-test Log (NVMe Log 0x06) Self-test status: No self-test in progress Num Test_Description Status Power_on_Hours Failing_LBA NSID Seg SCT Code 0 Short Completed without error 0 - - - - -


Hardware for Linux and BSD

GitHub